High Frequency IP67 Radar Level Meter

Min.Order: 5
Product origin: Nanjing, Jiangsu, China
Infringement complaint: complaintComplaint
US$ -1

Description
Radar Level Meter 

Product overview  
This series of radar level meter adopted 26G high frequency radar sensor, the maximum measurement range can reach up to 60 meters. Antenna is optimized further processing, the new fast microprocessors have higher speed and efficiency can be done signal analysis, the instrumentation can be used for reactor, solid silo and very complex measurement environment.


Features
Small antenna size, easy to install; Non-contact radar, no wear, no pollution.
Almost no corrosion, bubble effect; almost not affected by water vapor in the atmosphere, the temperature and pressure changes.
Serious dust environment on the high level meter work has little effect.
A shorter wavelength, the reflection of solid surface inclination is better.
Beam angle is small, the energy is concentrated, can enhance the ability of echo and to avoid interference.
The measuring range is smaller, for a measurement will yield good results.
High signal-to-noise ratio, the level fluctuation state can obtain better performance.
High frequency, measurement of solid and low dielectric constant of the best choice.






The instrument cannot be installed in the arched or domed roof intermediate. In addition to produce indirect echo is also affected
by the echoes. Multiple echo can be larger than the real value of signal echo, because through the top can concentrate multiple
echo. So cannot be installed in a central location.
Electrical Connection
The power supply voltage:
 
(4~20)mA/HART (Two wire system)   The power supply and the output current signal sharing a two core shield cable. The supply voltage range see technical data. For intrinsically safe type must be a safety barrier between the power supply and the instrument.
 
(4~20)mA/HART(Four wire system)   Separate power supply and the current signal, respectively using a two-core shielded cable. The supply voltage range see technical data.
 
RS485 / Modbus                   Power supply and Modbus signal line separated  respectively using a two-core shielded cable, the power supply voltage range see technical data.
 
Connection mode:
Technical Parameters
The outer shell  
The seal between the shell and the shell cover                Silicone rubber
Casing window                                            Polycarbonate
The ground terminal                                       Stainless steel
 
The power supply voltage
Two wire system            
The standard type                 (16 ~ 26) V DC
Intrinsically safe                   (21.6 ~ 26.4) V DC  
Power dissipation                  max 22.5mA / 1W                                           Allowable ripple 
- <100Hz                      Uss<lV                                                                                       - (100~100K) Hz               Uss<l0mV
 
The cable parameters
Cable entrance / plug                              1  M20xl.5 cable entrance
                                                  1  blind plug
Terminal                                           Conductor cross section 2.5mm²
Output parameters 
The output signal                                (4 ~ 20) mA/RS485
Communication protocol                           HART
Resolution                                        1.6μA
Fault signal                                       Constant current output; 20. 5mA
22mA
3.9mA
The integral time                                (0 ~ 36) s, adjustable
 
Blind area                                       the ends of the antenna
The maximum distance measurement             70 meters
 
Microwave frequency                              26GHz
 
Communication interface                          HART communication protocol
 
The measurement interval                 about 1 second (depending on the parameter settings)
 
Adjust the time                          about 1 second (depending on the parameter settings)
Display resolution                             1 mm
 
Working storage and transportation temperature                          (-40~100) ºC
Process temperature (the temperature of the antenna part)                 (-40~250)ºC
Pressure                                      Max.4MPa
 
Seismic                                       Mechanical vibration l0m/s², (10 ~ 150) Hz
 
Meter Linearity
Emission angle                   Depending on the size of the antenna
-¢76mm                                12°
-¢96mm                                8°
-¢121mm                              6°
Precision                              See chart
 