No. | item | |
1 | General test items | DC resistance of stator winding of drive motor |
Overspeed test | ||
Operating voltage range | ||
2 | Torque -speed -efficiency curve | Torque - Speed curve (universal curve) |
Motor controller speed - Efficiency universal curve | ||
Drive motor efficiency | ||
Drive motor system efficiency | ||
3 | Measurement of key characteristic parameters | Continuous torque |
Continuous power | ||
Peak torque | ||
peak power | ||
Maximum operating speed | ||
Efficient workspace | ||
Maximum efficiency | ||
4 | control accuracy | Speed control accuracy test |
Torque control accuracy test | ||
5 | Response | Speed response time |
Torque response time | ||
6 | Operating current of drive motor controller | Continuous operating current |
Short time operating current | ||
Max operating current | ||
7 | Continuous feed characteristics | |
8 | Controller protection function test | |
9 | Reliability test(GB/T 29307-2012) | |
10 | Short time voltage rise test | |
11 | Locked rotor torque and locked rotor current test | |
12 | Motor temperature rise test | |
13 | Load test | |
14 | Energy feedback test | |
15 | Road simulation test (climbing, acceleration, rolling resistance, etc.) | |
16 | Contact current test | |
17 | Simulation test of ramp starting, uphill and downhill taxiing | |
18 | Steady state cyclic loading durability test | |
19 | Other simulation tests (such as acceleration, braking, parking, etc.) or custom working conditions |
Model | XD40-800/24-100-1 | XD80-800/24-300-1 | XD120-800/24-500-1 | XD150-800/24-500-1 | XD250-800/24-667-1 | XD300-800/24-667-1 | |||||
Rated power | 40kW | 80kW | 120kW | 150kW | 250kW | 300kW | |||||
Peak power | 60kW | 120kW | 156kW | 180kW | 300kW | 360kW | |||||
Rated current | 100A | 300A | 500A | 500A | 667A | 667A | |||||
Peak current | 150A | 450A | 650A | 600A | 780A | 780A | |||||
Rated voltage | 400V | 267V | 240V | 300V | 375V | 450V | |||||
AC characteristics | |||||||||||
Input mode | 3P4W+PE | ||||||||||
Voltage | 380V±15% | ||||||||||
Frequency converter | 50Hz±5Hz | ||||||||||
Power factor | ≥0.99 | ||||||||||
THD | ≤4% | ||||||||||
DC characteristics | |||||||||||
Voltage range | 24V-800V | ||||||||||
Current range | 0-667A | ||||||||||
Voltage ripple | ≤0.2%F.S | ||||||||||
Voltage accuracy | ≤0.1%F.S | ||||||||||
Current accuracy | ≤0.2%F.S | ||||||||||
Feedback characteristics | |||||||||||
AC voltage | 323V~437V(Allowed voltage range) | ||||||||||
AC frequency | 45Hz~55Hz(Allowed frequency range) | ||||||||||
Power factor | ≥0.99 | ||||||||||
Feedback power | Support full scale power feedback | ||||||||||
Total harmonic content | ≤4% | ||||||||||
Communication and interface | |||||||||||
Local operation | touch screen | ||||||||||
Remote communication | Can (optional), RS485 (optional), Ethernet (standard) | ||||||||||
External interface | Support emergency stop, start / stop, fault detection, operation status detection, etc | ||||||||||
Safety and environment | |||||||||||
insulation resistance | ≥20MΩ | ||||||||||
Grounding resistance | ≤100mΩ | ||||||||||
Withstand voltage performance | 2000Vdc | ||||||||||
Protection function | Phase loss, overheating, overvoltage, voltage limiting, overcurrent, short circuit and overload | ||||||||||
Degree of protection | IP21 | ||||||||||
Ambient temperature | -20ºC~45ºC | ||||||||||
Ambient humidity | 10%~90%( No condensation) | ||||||||||
Altitude | ≤2000m | ||||||||||
Cooling mode | Forced fan | ||||||||||
Noise | ≤68dB | ||||||||||
Dimensions (W * D * H)mm | 615*650*1680 | 1000*1000*1960 | 1200*1000*1900 | 1200*1000*1900 | 1800*1000*1960 | 1800*1000*1960 |
Why Choose US?
• Professional team for after-sale service 7*24
• Experienced R & D team and profesional sales team
• OEM & ODM service, we will evaluate, design and produce your customized products
• Offer confidentiality agreement to protect your profit, with us your business will be in safe your money in safe.
Warranty:
As our customer, you enjoy the following services:
(1)One year repair for free of the complete machine;
(2)technical Support
(3) Within 24 hours for respond after receiving notification;
(4) Cost maintenance forever.