1. Consumer Electronics R&D and production, such as mobiles, tablets, earphones, etc.
2. BMS test and CMS test
3. Electric tools manufacturing test
4. Other battery-operated products manufacturing test
Main Features
*Voltage range: 0-6V/0-15VModel | N8358-06-01 | N8358-06-02 | N8358-06-03 |
Current | ±1A/CH | ±2A/CH | ±3A/CH |
Voltage | 6V/CH | 6V/CH | 6V/CH |
Power | 6W/CH | 12W/CH | 18W/CH |
Channels | 8CH | ||
CV Mode | |||
Range | 0-6V | ||
Setting Resolution | 0.1mV | ||
Setting Accuracy (23±5ºC) | 0.01%+1mV | ||
Readback Resolution | 0.1mV | ||
Readback Accuracy (23±5ºC) | 1mV+2d | ||
Voltage Settling Time | ≤10ms | ||
Load Regulation | 0.01%+1mV | ||
Line Regulation | 0.01%+0.1mV | ||
Temperature Coefficient(0~40ºC) | 25ppm/ºC | ||
Voltage Ripple (20Hz-20MHz) | 2mVrms | ||
Current Measurement | |||
Range 1 | |||
Range | -1~1A | -2~2A | -3~3A |
Resolution | 0.1mA | ||
Accuracy (23±5ºC) | 1mA+2d | 2mA+2d | 3mA+2d |
Temperature Coefficient (0~40ºC) | 50ppm/ºC | ||
Range 2 | |||
Range | -100mA~100mA | -200mA~200mA | -300mA~300mA |
Resolution | 0.01mA | ||
Accuracy (23±5ºC) | 0.1mA+2d | 0.2mA+2d | 0.3mA+2d |
Temperature Coefficient (0~40ºC) | 50ppm/ºC | ||
Range 3 | |||
Range | -1~1mA | ||
Resolution | 0.1μA | ||
Accuracy (23±5ºC) | 1μA+2d | ||
Temperature Coefficient(0~40ºC) | 50ppm/ºC | ||
Current Protection Limit | |||
Range | -1A~+1A | -2A~+2A | -3A~+3A |
Current Limit Resolution | 0.1mA | ||
Current Limit Accuracy (23±5ºC) | 1mA+2d | 2mA+2d | 3mA+2d |
Temperature Coefficient(0~40ºC) | 50ppm/ºC | ||
Dynamic Characteristics | |||
Transient Voltage Drop 1 | <200mV | ||
Transient Recovery Time 2 | <100μs | ||
DVM Function | |||
Channels | 8CH | Measurement Accuracy | ±0.01%F.S. |
Voltage Range | -30V~+30V | Measurement Frequency | 4Hz |
Measurement Resolution | 0.1mV | Input Impedance | 2MΩ |
Terminal | Pluggable terminal | Temperature Coefficient(0~40ºC) | 30ppm/ºC |
Others | |||
Interface | LAN/RS232 | ||
AC Input | Single phase, please refer to the voltage mark at the rear panel. | ||
Temperature | Operating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC | ||
Operating Environment | Altitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa | ||
Net Weight | Approx. 9kg | ||
Dimension | 2U, 88.0(H)*482.0(W)*557.0(D)mm |
Model | N8358-05-05 | N8358-15-01 | N8358-15-05 |
Current | ±5A/CH | ±1A/CH | ±5A/CH |
Voltage | 5V/CH | 15V/CH | 15V/CH |
Power | 25W/CH | 15W/CH | 75W/CH |
Channels | 8CH | ||
CV Mode | |||
Range | 0-5V | 0-15V | 0-15V |
Setting Resolution | 0.1mV | ||
Setting Accuracy (23±5ºC) | 0.01%+1mV | 0.01%+3mV | |
Readback Resolution | 0.1mV | ||
Readback Accuracy (23±5ºC) | 1mV+2d | 3mV+2d | |
Voltage Settling Time | ≤10ms | ||
Load Regulation | 0.01%+1mV | 0.01%+2mV | |
Line Regulation | 0.01%+0.1mV | 0.01%+0.2mV | |
Temperature Coefficient(0~40ºC) | 25ppm/ºC | ||
Voltage Ripple (20Hz-20MHz) | 2mVrms | 6mVrms | |
Current Measurement | |||
Range 1 | |||
Range | -5~5A | -1~1A | -5~5A |
Resolution | 0.1mA | ||
Accuracy(23±5ºC) | 5mA+2d | 1mA+2d | 5mA+2d |
Temperature Coefficient(0~40ºC) | 50ppm/ºC | ||
Range 2 | |||
Range | -500mA~500mA | -100mA~100mA | -500mA~500mA |
Resolution | 0.01mA | ||
Accuracy (23±5ºC) | 0.5mA+2d | 0.1mA+2d | 0.5mA+2d |
Temperature Coefficient(0~40ºC) | 50ppm/ºC | ||
Range 3 | |||
Range | -1~1mA | ||
Resolution | 0.1μA | ||
Accuracy (23±5ºC) | 1μA+2d | ||
Temperature Coefficient(0~40ºC) | 50ppm/ºC | ||
Current Protection Limit | |||
Range | -5A~+5A | -1A~+1A | -5A~+5A |
Current Limit Resolution | 0.1mA | ||
Current Limit Accuracy (23±5ºC) | 5mA+2d | 1mA+2d | 5mA+2d |
Temperature Coefficient(0~40ºC) | 50ppm/ºC | ||
Dynamic Characteristics | |||
Transient Voltage Drop 1 | <400mV | ||
Transient Recovery Time 2 | <200μs | ||
DVM Function | |||
Channels | 8CH | Measurement Accuracy | ±0.01%F.S. |
Voltage Range | -30V~+30V | Measurement Frequency | 4Hz |
Measurement Resolution | 0.1mV | Input Impedance | 2MΩ |
Terminal | Pluggable terminal | Temperature Coefficient(0~40ºC) | 30ppm/ºC |
Others | |||
Interface | LAN/RS232 | ||
AC Input | Single phase, please refer to the voltage mark at the rear panel. | ||
Temperature | Operating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC | ||
Operating Environment | Altitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa | ||
Net Weight | Approx. 9kg | ||
Dimension | 2U, 88.0(H)*482.0(W)*557.0(D)mm |