High Resolution 0.1mV 0.1mA Multi Channel Battery Packs Simulation Instrument
N83624 Series High-accuracy Multi-channel Battery Simulator


Product Introduction
N83624 is a programmable battery simulator with low-power, multi-channel and high-accuracy, suitable for BMS/CMS test. It is highly integrated, single device with up to 24 channels. Each channel is isolated. Users can set the voltage & current for each channel on application software, which is easy to use and can meet the needs of multi-channel and multi-data. The software can also provide graphs, data analysis and report function. N83624 is equipped with high-definition color LCD screen, available for local operation.

Application Fields
1.BMS/CMS 
2.Cell simulation

3.Smart Wearable 
4.Charging and standby test

5.Bluetooth earphone 
6.Sleep current and shutdown leakage current test

7.Electric Tool 
8.Motor driver and power loading test

9.Mobile Phone 
10.Charging and battery simulation


Main Features
*Voltage range: 0-6V/0-15V
*Current range: 0-1A/0-3A/0-5A
*Single device with up to 24 channels, each channel isolated
*Fast communication response , within 10ms for all channels programming response
*Remote sense for high accuracy
*Professional application software, with data analysis and report
*High-definition color LCD screen, available for local operation
*Standard 19-inch 3U, available for rack installation
*LAN port and RS232 interface; dual LAN ports, convenient for cascade application
*Fast dynamic response, less than 100μs for load varying from 10% to 90% and voltage recovering within 50mV of previous voltage

Ultra-high accuracy
N83624 current resolution is as low as 0.1μA. Ultra-high accuracy, ultra-low ripple and noise index make N83624 an ideal choice for battery simulation application. The ultra-high accuracy of N83624 output and measurement can be directly used in product calibration and test, eliminating the use of external high-accuracy measuring instruments and saving cost for users.

Ultra-high integration
N83624 integrates up to 24 channels that can be connected in series mode in 19-inch 3U size, providing a compact solution for ATE test systems in BMS, CMS and similar large-scale high-density production sites.


Battery simulation suitable for BMS chips test of various specifications
N83624 series battery simulators have multiple functions and features, supporting Source, All CH, Charge, SOC Test, SEQ, Graph, etc.
One device can achieve multiple uses, streamline test equipment and optimize test procedures. N83624's internal circuit is optimized for different chips, which can be adapted to test BMS chips of various specifications.

Fast dynamic response
N83624 series has fast dynamic response capability. The response time of load varying from 10% to 90% and voltage recovering within 50mV of previous voltage is less than 100μs, which can ensure the rising waveform of voltage or current is high-speed and without overshoot, and provide stable power for the DUT. This feature can meet the demand for product test with strict power requirements.


Exhibitions

Product Line
 
 
ModelN83624-06-01N83624-06-03N83624-06-05N83624-15-01
Current1A/CH3A/CH5A/CH1A/CH
Voltage6V/CH6V/CH6V/CH15V/CH
Power6W/CH18W/CH30W/CH15W/CH
Channel Number24CH
 CV Mode
Range0-6V0-15V
Setting Resolution0.1mV
Setting Accuracy(23±5ºC)0.01%+1mV0.01%+3mV
Readback Resolution0.1mV
Readback Accuracy(23±5ºC)0.01%+1mV0.01%+3mV
Temperature Coefficient (0-40ºC)20ppm/ºC
Long-term Stability80ppm/1000h
 Dynamic Characteristics
Voltage Rise Time <20μs ( no load ) (10%-90%F.S. Variation Time)<40μs
Voltage Rise Time               <20μs ( pure resistive full load ) (10%-90%F.S. Variation Time)<40μs
Voltage Fall Time <3ms ( no load ) (90%-10%F.S. Variation Time)<6ms
Voltage Fall Time                <100μs ( pure resistive full load ) (90%-10%F.S. Variation Time)<200μs
Transient Voltage Drop 1200mV400mV
Transient Recovery Time 2<100μs<200μs
 Current Measurement
Range0-1A0-1mA0-3A0-1mA0-5A0-1mA0-1A0-1mA
Readback Resolution0.1mA0.1μA0.1mA0.1μA0.1mA0.1μA0.1mA0.1μA
Readback Accuracy(23±5ºC)1mA+2d1μA+2d3mA+2d1μA+2d5mA+2d1μA+2d1mA+2d1μA+2d
Temperature Coefficient (0-40ºC)30ppm/ºC
Long-term Stability100ppm/1000h
 Current Protection Limit
Setting Value0-1A0-1mA0-3A0-1mA0-5A0-1mA0-1A0-1mA
Setting Resolution0.1mA0.1μA0.1mA0.1μA0.1mA0.1μA0.1mA0.1μA
Setting Accuracy(23±5ºC)1mA+2d1μA+2d3mA+2d1μA+2d5mA+2d1μA+2d1mA+2d1μA+2d
Temperature Coefficient (0-40ºC)30ppm/ºC
Long-term Stability100ppm/1000h
 Others
Load Regulation0.2mV0.4mV
Isolation (Output to Ground)1000VDC
Isolation (Inter-channel)500VDC
Communication Response TimeAll channels ≤10ms
InterfaceLAN/RS232
AC Input Single phase, please refer to the voltage mark at the rear panel.
TemperatureOperating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC
Operating EnvironmentAltitude <2000m, relative humidity: 5%~90%RH(non-condensing),
atmospheric pressure: 80~110kPa
Net WeightApprox. 17kg
Dimension3U, 132.5(H)*482.0(W)*559.0(D)mm

Note 1: Load varies from10% to 90% by full voltage output.
Note 2: Load varies from 10% to 90% by full voltage output, with voltage recovering within 50mV of previous voltage.
Note 3: For other specifications, please contact NGI.
Note 4: All specifications are subject to change without notice.