Model | N6206-60-50 | N6206-150-50 | N6206-600-10 | |||
Voltage | 60V | 150V | 600V | |||
Current | 50A | 50A | 10A | |||
Power | 600W | |||||
Min. Operating Voltage | 2V@50A | 2V@50A | 4.5V@10A | |||
CC Mode | ||||||
Range | 0-5A | 0-50A | 0-5A | 0-50A | 0-1A | 0-10A |
Setting Resolution | 0.1mA | 1mA | 0.1mA | 1mA | 0.1mA | 1mA |
Setting Accuracy (23±5ºC) | Low range:0.1%+0.1%F.S., High range:0.1%+0.15%F.S. | |||||
CV Mode | ||||||
Range | 0-6V | 0-60V | 0-15V | 0-150V | 0-60V | 0-600V |
Setting Resolution | 0.1mV | 1mV | 0.1mV | 1mV | 1mV | 10mV |
Setting Accuracy (23±5ºC) | 0.05%+0.1%F.S. | |||||
CP Mode | ||||||
Range | 0-600W | |||||
Setting Resolution | 10mW | |||||
Setting Accuracy (23±5ºC) | 0.5%+1%F.S | |||||
CR Mode | ||||||
Range | 0.03~120Ω | 0.5Ω~1200Ω | 0.06Ω~300Ω | 1.2Ω~3000Ω | 1.12Ω~6000Ω | 22.4Ω~60000Ω |
Setting Resolution | 16bits | |||||
Setting Accuracy (23±5ºC) | 0.35%+26.04mS | 0.35%+2.6mS | 0.35%+10.41mS | 0.35%+1.04mS | 0.35%+0.52mS | 0.35%+0.05mS |
Slew Rate | ||||||
Current | 0.8-50A/ms | 50-2500A/ms | 0.8-50A/ms | 50-2500A/ms | 0.1-10A/ms | 10-500A/ms |
Voltage | 0.5-25V/ms | 25-250V/ms | 10-60V/ms | 60-600V/ms | 5.0-250V/ms | 250-2500V/ms |
Power | 0.8-50A/ms | 50-2500A/ms | 0.8-50A/ms | 50-2500A/ms | 0.1-10A/ms | 10-500A/ms |
Resistance | 0.8-50A/ms | 50-2500A/ms | 0.8-50A/ms | 50-2500A/ms | 0.1-10A/ms | 10-500A/ms |
Accuracy (23±5ºC) | (1+35%)*Setting value | |||||
Voltage Measurement | ||||||
Range | 0-6V | 0-60V | 0-15V | 0-150V | 0-60V | 0-600V |
Readback Accuracy (23±5ºC) | 0.05%+0.1%F.S | |||||
Current Measurement | ||||||
Range | 0-5A | 0-50A | 0-5A | 0-50A | 0-1A | 0-10A |
Readback Accuracy (23±5ºC) | 0.05%+0.1%F.S. | |||||
Power Measurement | ||||||
Range | 0-600W | |||||
Readback Accuracy (23±5ºC) | 0.5%+1%F.S. | |||||
Dynamic Mode | ||||||
T1&T2 | 0.025-60ms | 1-60000ms | 0.025-60ms | 1-60000ms | 0.025-60ms | 1-60000ms |
Resolution | 1μs | 1ms | 1μs | 1ms | 1μs | 1ms |
Accuracy (23±5ºC) | 1μs+100ppm | 1ms+100ppm | 1μs+100ppm | 1ms+100ppm | 1μs+100ppm | 1ms+100ppm |
Others | ||||||
Interface | LAN/RS232 | |||||
AC Input | Single phase, 220V AC±10%, frequency 47Hz~63Hz | |||||
Temperature | Operating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC | |||||
Operating Environment | Altitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa | |||||
Net Weight | Approx. 13kg | |||||
Dimension | 2U, 88.0(H)*482.0(W)*507.0(D)mm |
Model | N6212-60-100 | N6212-150-100 | N6212-600-20 | |||
Voltage | 60V | 150V | 600V | |||
Current | 100A | 100A | 20A | |||
Power | 1200W | |||||
Min. Operating Voltage | 2V@100A | 2V@100A | 4.5V@20A | |||
CC Mode | ||||||
Range | 0-10A | 0-100A | 0-10A | 0-100A | 0-2A | 0-20A |
Setting Resolution | 0.1mA | 1mA | 0.1mA | 1mA | 0.1mA | 1mA |
Setting Accuracy (23±5ºC) | Low range:0.1%+0.1%F.S., High range:0.1%+0.15%F.S. | |||||
CV Mode | ||||||
Range | 0-6V | 0-60V | 0-15V | 0-150V | 0-60V | 0-600V |
Setting Resolution | 0.1mV | 1mV | 0.1mV | 1mV | 1mV | 10mV |
Setting Accuracy (23±5ºC) | 0.05%+0.1%F.S. | |||||
CP Mode | ||||||
Range | 0-1200W | |||||
Setting Resolution | 10mW | |||||
Setting Accuracy (23±5ºC) | 0.5%+1%F.S | |||||
CR Mode | ||||||
Range | 0.02~60Ω | 0.3Ω~600Ω | 0.03Ω~150Ω | 0.6Ω~1500Ω | 0.56Ω~3000Ω | 11.2Ω~30000Ω |
Setting Resolution | 16bits | |||||
Setting Accuracy (23±5ºC) | 0.35%+52mS | 0.35%+5.2mS | 0.35%+20.8mS | 0.35%+2.08mS | 0.35%+1mS | 0.35%+0.1mS |
Slew Rate | ||||||
Current | 1.6-100A/ms | 100-5000A/ms | 1.6-100A/ms | 100-5000A/ms | 0.3-20A/ms | 20-1000A/ms |
Voltage | 0.5-25V/ms | 25-250V/ms | 10-60V/ms | 60-600V/ms | 5.0-250V/ms | 250-2500V/ms |
Power | 1.6-100A/ms | 100-5000A/ms | 1.6-100A/ms | 100-5000A/ms | 0.3-20A/ms | 20-1000A/ms |
Resistance | 1.6-100A/ms | 100-5000A/ms | 1.6-100A/ms | 100-5000A/ms | 0.3-20A/ms | 20-1000A/ms |
Accuracy (23±5ºC) | (1+35%)*Setting value | |||||
Voltage Measurement | ||||||
Range | 0-6V | 0-60V | 0-15V | 0-150V | 0-60V | 0-600V |
Readback | 0.05%+0.1%F.S | |||||
Accuracy (23±5ºC) | ||||||
Current Measurement | ||||||
Range | 0-10A | 0-100A | 0-10A | 0-100A | 0-2A | 0-20A |
Readback Accuracy (23±5ºC) | 0.05%+0.1%F.S. | |||||
Power Measurement | ||||||
Range | 0-1200W | |||||
Readback Accuracy (23±5ºC) | 0.5%+1%F.S. | |||||
Dynamic Mode | ||||||
T1&T2 | 0.025-60ms | 1-60000ms | 0.025-60ms | 1-60000ms | 0.025-60ms | 1-60000ms |
Resolution | 1μs | 1ms | 1μs | 1ms | 1μs | 1ms |
Accuracy (23±5ºC) | 1μs+100ppm | 1ms+100ppm | 1μs+100ppm | 1ms+100ppm | 1μs+100ppm | 1ms+100ppm |
Others | ||||||
Interface | LAN/RS232 | |||||
AC Input | Single phase, 220V AC±10%, frequency 47Hz~63Hz | |||||
Temperature | Operating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC | |||||
Operating Environment | Altitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa | |||||
Net Weight | Approx. 14.5kg | |||||
Dimension | 2U, 88.0(H)*482.0(W)*507.0(D)mm |