Evaporative Condenser Integrated Stainless Steel Design Refinery Industrial Cooling System

Min.Order: 1
Product origin: Wuxi, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 700 ~ 50000

Description
Product Description

Evaporative condenser integrated stainless steel design refinery industrial cooling system

Solemn Promise

Our commitment to provide five years of original manufacturer's quality assurance period, in this warranty period due to the product's own reasons for failure, our commitment:

1, Immediately after receiving the user's notice to respond, and timely and free of charge to assist in analysing and troubleshooting, free of charge to provide the appropriate parts;
2, In the warranty period, due to improper use of the user caused by the failure, our company in the user's notice received an immediate response, and timely arrangements for after-sales docking your relevant technical personnel troubleshooting, repair or replacement of parts, need to replace the parts, discretionary cost of the parts fee.
3, After the expiration of the warranty period, when there is a failure, our company will actively arrange the after-sales docking your company to troubleshoot, repair or replace the parts, and charge the cost of parts and service charges as appropriate.

Operating Principle

 Product Parts


CTI Certificated Mixed-Flow Closed Cooling Tower / Evaporative Condenser / Cooling Chiller by China Leading Factory DJS.

Mixed-Flow Closed Cooling Tower / Dry-wet Cooling Chiller / 
CTI Certificated Water-Coolilng Tower / Water Chiller / Water or Air COOLED CHILLER for Most Industries' use on heat-exchange purposes.

Technical Specifications 
Model No.Nominal TonsFanSpray PumpGas InletLiquid OutletOverall  Dimensions (mm)Weight
Power (kW)Air Volumn (m3/s)Power (kW)Flow Rate (T/h)LWHNet   (kg)Operation (kg)
WZM-1001001.13.90.7516DN40DN3211307702800500970
WZM-1151151.550.7516DN40DN32115089030256001070
WZM-1301301.550.7516DN40DN32115089030256201100
WZM-1451451.55.60.7516DN40DN321160105030758001280
WZM-1601601.55.60.7516DN40DN321160105030758201300
WZM-1801802.26.90.7516DN80DN8017101125321011501630
WZM-2002002.26.90.7516DN80DN8017101125321011701650
WZM-22022037.50.7516DN80DN8018351220321012501950
WZM-24024037.50.7516DN80DN8018351220321012701970
WZM-28028038.90.7516DN80DN8016801220340012001900
WZM-30030038.90.7516DN80DN8016801220340012201920
WZM-320320411.10.7516DN80DN8018801250340014002100
WZM-340340411.10.7516DN80DN8018801250340014202120
WZM-360360412.50.7522DN80DN8020001350340016502350
WZM-380380412.50.7522DN80DN8020001350340016702370
WZM-400400412.50.7522DN80DN8020001350340016902390
WZM-430430418.11.545DN100DN10018302410430024903830
WZM-475475418.11.545DN100DN10018302410430027004050
WZM-4954955.519.71.545DN100DN10018302410430027104060
WZM-550550417.62.275DN100DN10019303010435033104980
WZM-5955955.521.72.275DN100DN10019303010435033204990
W7M-6706705.521.72.275DN100DN10019303010435037005380
WZM-7007005.521.72.275DN100DN10019303010495038005890
WZM-7357357.524.22.275DN100DN10019303010495038105900
WZM-7807805.522.22.275DN100DN10019853210499040406200
WZM-8708707.527.82.275DN100DN10019853210499040506210
WZM-9409401134.72.275DN100DN10019853210499040606220
WZM-9609604.0×218.1×22.2114DN100×2DN10035752410430049207590
WZM-100010005.5×219.7×22.2114DN100×2DN10035752410430049407610
WZM-105010507.5×221.9×22.2114DN100×2DN10035752410430049607630
WZM-116511654.0×217.6×23.7140DN100×2DN100377527104950607010210
WZM-128512855.5×221.7×23.7140DN100×2DN100377527104950609010230
WZM-133513357.5×224.2×23.7140DN100×2DN100377527104950611010250
WZM-142014205.5×221.7×23.7140DN100×2DN100377530104950705011250
WZM-149014907.5×224.2×23.7140DN100×2DN100377530104950707011270

When temperature is lower than a certain temperature(-10ºC), or output temperature lower than a set temperature, the spray pump stops working, and the Cooling Tower can be working under a dry cooling mode, with no evaporating loss to save the water and energy.

Wet Cooling Mode
When temperature is higher than a certain temperature(-2ºC), or output temperature higher than a set temperature, the spray pump starts working, and the cooling tower can be working under a wet cooling mode. This Evaporative Cooling ensures a big cooling capacity.

 

Structural Features

The condenser and cooling tower organically integrated, energy saving.

Air and water flow same, affect the heat transfer coefficient.

Heat exchange pipe tilt design, it is good for refrigerant flow, reduce the flow resistance.

Evaporation condenser side have maintance door, easy for maintenance.

Axial flow fan blades is die casting aluminum, light weight, low noise,high efficiency and motor is waterproof.

Heat exchange coil and internal black metal artifacts have been hot-dip zinc process, good anti-corrosion performance, long life time ;Heat exchange coil with special structural design, make the coil arrangement more compact, increased in the same plane coil area, improving the heat transfer efficiency.

Using anti-blocking type spray system, large coverage area .

Use high-efficiency dehydrator, dehydration with high efficiency, water loss is small.

Heat exchange coil with heat transfer layer below the secondary water distribution, increase the contact area, reduce the water temperature, spray water cooling effect is good, so as to ensure the evaporation condenser effect.
Project Case 
 

Loading & Shipping

 

 
Why Choose Us
a. Cross flow, Induced Draft, Eco-Friendly Type, keep fluid inside clean
b. Equipped with high effective evaporative type heat exchange coil, 100% cooing capacity guarantee.
c. Equipped with fill for spraying water cooling, reduce coil area required, more cost effective.
d. Reduce the possibility of coil scaling as the direction of air flow same to the spraying water  
e. Large door, space and aisle inside for maintenance and repair.
f. Equipped with famous brand driven device, energy saving and reliable.

 
 
FAQ

FAQ:

Q1. Are you manufacturer?
We are manufacture factory, with Research Team.

Q2. What's the order process?
1) Inquiry---provide us the Needs / Key Data.
2) Quotation--- Solutions with Pirces
3) P/I--Confirm Orders
4) Payment terms: T/T deposit 
5) Production: 3-7 weeks upon deposit
6) Shipping
7) After-sales Service.

Q3. How to get a prompt quotation?
Pls kindly offer us the key request as below:
A. Inlet and outlet Temperature
B. Drybulb and Wetbulb Temperature
C.Voltages and Frequency
D.The cooling tower, used in the environment, and what equipment the tower is used for, etc.


 
Company Profile

About us

       Ding Jisheng Cooling Equipment is a professional manufacturer of cooling and heat exchange equipment, our products are widely used in cooling water and other process fluids.
       Our company focus on the research, design and manufacture of standard and customized cooling equipment.
       Our products are characterized by its high efficiency, high corrosion resistance, low noise, environmental protection, easy installation, convenient operation, stable performance and long service life etc.
       Our products are widely used in various fields.
       We provide the most competitive cooling equipment and solutions, also offering ongoing support!
     
Product Tag:
Related categories:
Scroll to Top