ASCB1 series intelligent micro circuit breakers (hereinafter referred to as intelligent micro circuit breakers) are applied to low-voltage terminal distribution networks in industrial, commercial, civil buildings and infrastructure fields in residential buildings and similar places.The intelligent micro circuit breaker is used with the intelligent gateway to conduct real-time monitoring of the key electrical parameters of the power line, such as voltage, current, power, temperature, leakage, energy consumption, etc., and has remote control, abnormal warning, accident trip warning alarm, electric energy metering statistics, fault positioning and other functions.
This series of products can be selected from unipole, 2 pole, 3 pole, 4 pole.
Detailed Photos

ModelASCB1-63ASCB1LE-63
Pole1P/2P/3P/4P2P/4P
Grade of Shell63A
Rated Voltage230V(1P/2P),400V(3P/4P)
Rated Current6A,10A,16A,20A,25A,32A,40A,50A,63A
Instantaneous Unbuckle TypeC/D
Rated Short-circuit Breaking Capacity6000A








Protect
Over-current ProtectionDefault 100% rated current alert,
110% Rated current trip with adjustable threshold
Short-circuit Protection5-10 Rated current for 0.04 seconds for circuit break protection
Overload ProtectionDefault 100% rated power alert,110% Rated power trip with adjustable threshold
Over-voltage ProtectionDefault 110% rated voltage alert,120% rated voltage trip with adjustable threshold
Under-voltage ProtectionDefault 90% rated voltage alert,80% rated voltage trip with adjustable threshold
Over-temperature ProtectionDefault 80ºC alert,100ºC trip, the threshold is adjustable
Leakage ProtectionNoDefault 20mA alert, 30mA trip, the threshold is adjustable
Leakage self-InspectionNoManual button self-inspection
Mechanical Life20000 times
Electrical Life6000 times
Levels of ProtectionIP20
Connection Capacity1-35mm²
Elevation Requirements2000m
Ambient Temperature-10ºC~55ºC,the average temperature at 24h was no higher than 40ºC
Environmental RequirementsNo explosion hazard, no conductive dust, no sufficient corrosion of metal and damaged insulation, no significant vibration
Relative HumidityAt + 40ºC, the relative humidity of the air is 50% and can have high relative humidity at lower temperatures
Storage Temperature-20ºC-70ºC
Class of Pollution 
Installation Type 
Way to InstallationStandard 35mm guide rail installation
  1. The device is suitable for standard 35mm rail type installation. When installing, just clip the device into the rail and fix it with a buckle .
  2. According to the actual power distribution management and line laying design requirements, select and use IoT modules and electrical boxes that meet the needs.
  3. The specifications of the box are assembled and installed in the order of the modules shown in the figure, and each module is   connected by a special 8PIN data cable made by the manufacturer.

4) The circuit breaker should be installed vertically. When the handle is in "/OFF", the contacts are disconnected. When the handle moves upward, the contacts move in the closing direction.

FAQ
 Q: Can the circuit breaker data be collected through RS485 communication?
A: The circuit breaker has its own RS485 communication interface, and it does not need to be equipped with an ASCB1-M gateway to access the customer system, but the customer needs to provide the circuit breaker with DC12V 12A auxiliary power supply

Q: How many circuit breakers can a gateway carry?
A: 16PCS

Q: How Gateways and Circuit Breakers are Networked?
A: The gateway and the circuit breaker are connected by a 4pin cable, a set of DC12V auxiliary power supply, and a set of RS485 communication lines.
The connection between the circuit breaker and the circuit breaker is the same.
One-key addressing operation through the gateway

Q: Does the circuit breaker need to be equipped with additional accessories?
A: 1. Internally integrate various sensor modules, including: current sensor, leakage transformer, temperature sensor, etc.;
2. The circuit breaker integrates the release function, which can realize remote opening and closing operations;
3. Configure the circuit breaker network cable
Certifications

 
Packaging & Shipping

 

Company Profile

 

Product Tag:
Related categories:
Scroll to Top