Description
Introduction:The Flooring Radiant Panel Tester is the cornerstone of the flooring materials reaction to fire tests in the Euroclass system. The tester measures the spread of flame of the sample, under thermal exposure, using a radiant heat ignition source. The thermal exposure is that of a fire growing in the room of origin that through a door opening, radiates onto the floorings in an adjacent room or corridor.
The Flooring Radiant Panel Tester can also be used for tests to standards ASTM E648 and DIN 4102 Part 14.
Standard:· ISO 9239-1:Floor coverings - Fire reaction test - Part 1: Determination of flaming performance using radiant heat sources;
· ASTM E648:The floor covering is subjected to a critical thermal radiation test using a thermal radiation source method;
· DIN 4102-14: Fire behaviour of building materials and elements - Determination of the burning behaviour of floor covering systems using a radiant heat sourceFeature1. The stainless steel test box adopts a front door design, which is easy to clean the inner wall of the box;
2. The inner wall of the box is made of calcium silicate board, which is resistant to high temperature and corrosion;
3. The stainless steel fume collecting hood device is placed above the combustion test box;
4. 300mm X 450mm porous ceramic heat radiation board, placed at an angle of 30 degrees;
5. Provide T-shaped porous burner, apply open flame to the sample, adopt cylinder push mode;
6. The light path system includes a light source of 2900 ± 100 K color temperature incandescent lamp, and the light source is a silicon photodiode;
7. The shutter is placed in the front of the silicon photodiode, which can be automatically opened and closed by the computer test software, which is convenient for calibration and use;
8. Rotameter adjusts the flame height of T-burner;
9. The propane mass flow meter adjusts the gas flow of the radiant panel and displays it digitally;
10.The Flooring Radiant Panel Tester is supplied with a blower to provide the air source, and the gas used for the mixed test of the Venturi mixture;
11. The mass flow controller is used to adjust the air intake flow of the radiant panel;
12. SB water-cooled heat flow meter, the working range is 0-50 kW/m2, the accuracy of the heat flow meter is <±2%, and the response time is 0.2 s. It provides a portable cooling water source without external water;
13. The user can move the heat flow meter to easily calibrate the heat radiation flux of the radiant panel, and the test software can draw a standard heat radiation flux curve;
14. The Flooring Radiant Panel Tester is equipped with a foot switch, the user can obtain the flame spread time to reach the test distance according to the flame spread distance, and the computer can record it by itself;
15. Install a chimney thermocouple and one thermocouple in the box, and display it by computer software;
16. The Flooring Radiant Panel Tester is equipped with an infrared radiometer, which can detect the temperature of the radiation panel and display it by computer software;
17. The Flooring Radiant Panel Tester adopts 15-inch industrial touch screen computer, users can monitor the entire combustion test process through the test software;
18. The software can display test-related information such as heat radiation flux value, smoke density curve, transmittance curve, and wind speed.
Technical parameters
Maximum operating power | 5kw |
Timing accuracy | <1s / h |
Heat flux meter Measuring range | (0-15) Kw / m2; (heat flow customer-owned) |
Heat flux meter accuracy | ± 0.2Kw / m2 |
Heat radiation pyrometer range | 400-600 ºC, the accuracy of ± 0.5 ºC; |
Black body temperature error | ± 5 ºC; |
Smoke speed | (2.5 ± 0.2) m / s |
Smoke capacity | (39-85) m3 / min |
Porous refractory radiation board size | 300mm × 450mm, the ability of about 900 ºC high temperature; |
Thermocouple | diameter of 3.2mm K-type stainless steel armored thermocouple |
Burning torch | diameter ¢ 10mm diameter ¢ 6mm, spray tube on the 35 ¢ 0.7mm hole |
Flame height | 60 ~ 120mm adjustable |
Ignition system | high voltage electronic ignition |
Burning box size | L1420 * W1200 * H2300 (mm) |
Strong exhaust system | Flooring Radiant Panel Tester is equipped with a strong fan, when the test is completed, start the exhaust fan system will be exhausted outdoors |
Installation requirements
1 | Electrical | 230 volts Nominal 10 Amps |
2 | Ambient Temperature | Operating 10°C to 35°C |
3 | Dimensions | Apparatus: 1900mm (W) x 750mm x (H) x 2120mm (D) |
4 | Gas Supplies | Propane and air compressor |
5 | Weight | 235KG |
Factory overview
Customer Feedback GermanyUSATransporation
FAQ
1.What's the delivery time?About 2 months.2.What's your payment terms?30% paid by T/T in advance,70% paid by by T/T before shipping.3.What's your guarantee terms?The warranty of all products is 1 year.During this period,we are responsible for all faults caused by us.And we can supply life-long technical support. 4.Can you supply training?We can supply training in our factory and online training for free.If onsite installation and training are required,please pay for tickets,accommodation and salary USD150/Day for every person.