TUNKIA TI5800 Current Sensor Current Transformer testing Power Supply and Output Measurement Test equipment

Min.Order: 1
Product origin: Changsha, Hunan, China
Infringement complaint: complaintComplaint
US$ 1000 ~ 10000

Description

TI5800 Sensor Power Supply and Output Tester

1. Summary

TI5800 integrates a precision voltmeter, precision ammeter, and programmable adjustable voltage source. It supplies power to a voltage or current sensor when testing it, and accurately measures the sensor's secondary output current Is or voltage Us. This instrument can be combined with a standard current source or voltage source to form a sensor testing device to test voltage or current sensors.

2. Feature

  1. Voltage Us Measuring Range:10 mV ~ 12 V.
  2. Current Is Measuring Range:1 mA ~ 1.1 A.
  3. Measurement Frequency: DC,AC 45 Hz~1 kHz(Optional).
  4. DC Measurement Uncertainty: 50 ppm.
  5. Built-in DC ±(5.0 V~50 V) adjustable power supply.
  6. Supports power consumption measurement of the tested sensor.
  7. Optional connection adapter to match the sensor interface of DB9.
  8. Optional 1~4 measurement channels.

3. Application

 Sensor power supply and measurement of secondary signals
Sensor Secondary Signal Measurement Module
  1. Built-in standard ammeter and standard voltmeter can accurately measure the secondary output Is or Us of the sensor.
  2. It can be used with standard current sources or voltage source groups to test the proportional error of voltage or current sensors.
Sensor Power Supply Module
  1. Built-in DC ±(5 V ~ 50 V) adjustable power supply can test the power supply impact of the sensor under test.
  2. A standard ammeter is connected in series in the power supply module loop. It can measure the no-load or full-load power consumption of the sensor being tested.
 

4. Specification

4.1 DC Voltage/Current Measurement

Current Range10 mA,100 mA,1 A,manual/automatic range switching.
± (1 mA ~ 1.1 A)
Voltage Range100 mV,1 V,10 V,manual/automatic range switching.
± (10 mV ~ 12 V)
Measurement Uncertainty(k=2)0.003%*RD + 0.002%*RG [1]
Temperature Coefficient@ (0°C~40°C)2 ppm*RD/°C
Display 7-digit decimal
Note[1]: RD is the reading value, RG is the range value, the same below.
 

4.2 AC Voltage/Current Measurement (Optional)

Current Range10 mA,100 mA,1 A,manual/automatic range switching.
1 mA ~ 1.1 A
Voltage Range100 mV,1 V,10 V,manual/automatic range switching.
10 mV ~ 12 V
Measurement Frequency45 Hz ~ 1 kHz
Measurement Uncertainty(k=2)0.006%*RD + 0.004%*RG
Temperature Coefficient@ (0°C~40°C)5 ppm*RD/°C
Display 7-digit decimal

5. General Specification

Power SupplyAC ( 220 ± 22 ) V,(50±2) Hz
Maximum Power Consumption100 VA
Warm-up Time2 times the last predicted warm-up time, up to 30 minutes.
Working EnvironmentTemperature: 0°C ~ 40°C
Humidity: 20%R·H ~ 80%R·H,no condensation.
Others: No electromagnetic field interference.
Storage EnvironmentTemperature: -20°C ~ 70°C
Humidity: <95%R·H,no condensation.
Altitude< 3000 m
Communication InterfaceRS232×1
 

6. Ordering Information