Medium/High Voltage Hvc Svg Static Var Generator Reactive Power Compensation Device

Min.Order: 1
Product origin: Jinan, Shandong, China
Infringement complaint: complaintComplaint
US$ 20000

Description
SVG
Compared with the traditional SVC device represented by TCR, the regulation speed of the static var generator (SVG) is faster and the operation range is wider. Moreover, after adopting multiple and equal PWM technical measures, the content of carrier frequency harmonics in compensation current is reduced. More importantly, the reactor and capacitor elements used in SVG are much smaller than those used in SVC, which will greatly reduce the volume of the device. VPV series low voltage static var generator (SVG) has such advantages, which represents the development direction of dynamic var compensation device. The PV series SVG developed and produced by our company realizes the comprehensive coverage of power consumption systems and is widely used in different industries and working conditions. It is divided into 200V series, 400V series, 600V series, and high-voltage series according to the user's service voltage level. The modularization of the power unit makes it easy to expand the capacity of the device, and the independence of the module greatly improves the reliability of the whole machine.


SVG Characteristics
1. Modular design is adopted, and each module unit can compensate reactive power and harmonic separately or at the same time

2. Strong ability to control fluctuation and flicker
3. Using PWM interleaving technology, it's own harmonic is very low
4. Fast response speed, less than or equal to 3MS
5. Low power consumption and small floor area
6. Increase the power grid capacity, reduce losses and purify the power grid
7. Design life 20 years
8. Easy installation and commissioning, no wearing parts, and easy maintenance

 SVG Application field

1.Power system requiring comprehensive compensation for reactive power and harmonic
2.Electrolytic industry using special AC voltage
3.Power consumption systems in areas with low power factors, such as factories, enterprises, etc.
4.Manufacturers using high-power nonlinear load and impact load (such as air pump, etc.)
5.Remote areas with poor power consumption, such as rural areas, mountainous areas, wind farms, etc.
6.Power consumption systems with high requirements for power grid quality, such as hospitals, etc.

Technical parameters of 220V series SVG
SpecificationsVPVG02-140DFVPVG02-280DFVPVG02-420DFVPVG02-560DFVPVG02-840DFVPVG02-1120DFVPVG02-1400DFVPVG02-2100DFVPVG02-2800DF
Rated voltage (VAC)
 
220
Input voltage range (VAC)
 
220±20%
Operating frequency (Hz)
 
50±5%
Rated capacity (Kvar)
 
±140±280±420±560±840±1120±1400±2100±2800
Equivalent capacitance (Kvar)
 
21042063084012601680210031504200
Rated current (A)
 
3677351102147022042940367055127350
Overload current multiple
 
1.2
Overall dimension / M (WxDxH)
 
600×800×2200900×800×22001200×800×22001800×800×22002900×800×22003500×800×22005000×800×22006500×800×2200
Wire system
 
Three-phase three-wire
Secondary incoming line mode
 
Lower incoming line
Operating ambient temperature (ºC)
 
-25 ~ + 45 ºC (derating is required above 40 ºC)
Operating ambient humidity (%)
 
< 95% no condensation
Cooling mode
 
Forced air cooling
Degree of protection
 
IP21/IP20
Working altitude
 
0 ~ 3000m (> 2000m, need to reduce capacity)
Reactive power regulation range
 
Continuously adjustable from rated capacitive reactive power to rated inductive reactive power
harmonic
 
Meet the requirements of power quality and harmonics in the public power grid (GB/T 14549-93)
response time
 
3ms
display
 
TFT true color touch screen, real-time voltage, and current data display
Intelligent communication
 
TCP/IP GPRS Modbus
Storage, transportation, temperature-40~70ºCC
Reliability and life
 
Design life 20 years
electromagnetic compatibilityComply with GB 7251-2005 (GB/T 7261-2000)

Remarks:
1. The unit incoming line mode is divided into forwarding line type and backward line type, which can be selected;
2. The product specifications and parameters of the above SVG models may change due to different on-site working conditions or      actual needs of users;
3. The matching relationship in the table is not unique, and users can choose by themselves according to the application situation; 4. Due to different options, the size of the SVG cabinet may change;
5. If the width is less than 1200mm (included), it is a single cabinet installation.


400V series SVG technical parameters
SpecificationsVPVG04-50DFVPVG04-75DFVPVG04-100DFVPVG04-150DFVPVG04-200DFVPVG04-300DFVPVG04-400DFVPVG04-500DFVPVG04-600DFVPVG04-800DFVPVG04-1000DFVPVG04-1200DF
Rated voltage (VAC)
 
400
Input voltage range (VAC)
 
400±20%
Operating frequency (Hz)
 
50±5%
Rated capacity (Kvar)
 
±50±75±100±150±200±300±400±500±600±800±1000±1200
Equivalent capacitance (Kvar)75115150225300450600750900120015001800
Rated current (A)
 
72108144216288432576720864115214401728
Overload current multiple
 
1.2
Overall dimension / M (WxDxH)
 
600×800×2200600×800×2200800×800×22001000×800×22001400×800×22001600×800×2200
Wire system
 
Three-phase three-wire / three-phase four-wire
Secondary incoming line mode
 
Lower incoming line / upper incoming line/cabinet busbar
Operating ambient temperature (ºC)
 
-25 ~ + 45 ºC (derating is required above 40 ºC)
Operating ambient humidity (%)
 
< 95% no condensation
Cooling mode
 
Forced air cooling
Degree of protection
 
IP21/IP20
Working altitude
 
0 ~ 3000m (> 2000m, need to reduce capacity)
Reactive power regulation range
 
Continuously adjustable from rated capacitive reactive power to rated inductive reactive power
harmonic
 
Meet the requirements of power quality and harmonics in the public power grid (GB /T 14549-93)
response time
 
3ms
display
 
TFT true color touch screen, real-time voltage, and current data display
Intelligent communication
 
TCP/IP GPRS Modbus
Storage, transportation, temperature-40~70ºCC
Reliability and life
 
Design life 20 years
electromagnetic compatibilityComply with CB 7251-2005 (GB/T 7261-2000)

Remarks:
1. The unit incoming line mode is divided into forwarding line type and backward line type, which can be selected;
2. The product specifications and parameters of the above SVG models may change due to different site conditions or actual              needs;
3. The matching relationship in the table is not unique and can be selected according to the application;
4. Due to different options, the size of the SVG cabinet may change;
5. Single cabinet installation with the width less than 1000mm (included)


 600V series SVG technical parameters
SpecificationsVPVG06-200DFVPVG06-300DFVPVG06-600DFVPVG06-900DFVPVG06-1200DFVPVG06-1800DFVPVG06-3000DFVPVG06-6000DFVPVG06-9000DF
Rated voltage (VAC)
 
600
Input voltage range (VAC)
 
600±20%
Operating frequency (Hz)
 
50±5%
Rated capacity (Kvar)
 
±200±300±600±900±1200±1800±3000±6000±9000
Equivalent capacitance (Kvar)
 
3004509001350180027004500900013500
Rated current (A)
 
19228957786611551732288757748661
Overload current multiple
 
1.2
Overall dimension / M (WxDxH)
 
600×800×2200600×800×2200900×800×22001200×800×22001800×800×22003500×800×22006500×800×22009500×800×2200
Wire system
 
Three-phase three-wire
Secondary incoming line mode
 
Lower incoming line
Operating ambient temperature (ºC)
 
-25 ~ + 45 ºC (derating is required above 40 ºC)
Operating ambient humidity (%)
 
< 95% no condensation
Cooling mode
 
Forced air cooling
Degree of protection
 
IP21/IP20
Working altitude
 
0 ~ 3000m (> 2000m, need to reduce capacity)
Reactive power regulation range
 
Continuously adjustable from rated capacitive reactive power to rated inductive reactive power
harmonic
 
Meet the requirements of power quality and harmonics in the public power grid (GB/T 14549-93)
response time
 
3ms
display
 
TFT true color touch screen, real-time voltage, and current data display
Intelligent communication
 
TCP/IP GPRS Modbus
Storage, transportation, temperature-40~70ºCC
Reliability and life
 
Design life 20 years
electromagnetic compatibilityComply with GB 7251-2005 (GB 7261-2000)

Technical parameters of 1140V series SVG
SpecificationsVPVG1-500DFVPVG1-1000DFVPVG1-2000DFVPVG1-3000DFVPVG1-4000DFVPVG1-5000DFVPVG1-6000DFVPVG1-8000DFVPVG1-10000DF
Rated voltage (VAC)
 
1140
Input voltage range (VAC)
 
1140±20%
Operating frequency (Hz)
 
50±5%
Rated capacity (Kvar)
 
±500±1000±2000±3000±4000±5000±6000±8000±10000
Equivalent capacitance (Kvar)
 
7501500300045006000750090001200010500
Rated current (A)
 
2535061013152020262532303940525065
Overload current multiple
 
1.2
Overall dimension / M (WxDxH)
 
900×900×22001200×900×22002400×900×22003600×900×22004800×900×22006000×900×22007200×900×22009600×900×220012000×2200
Wire system
 
Three-phase three-wire
Secondary incoming line mode
 
Lower incoming line
Operating ambient temperature (ºC)
 
-25 ~ + 45 ºC (derating is required above 40 ºC)
Operating ambient humidity (%)
 
< 95% no condensation
Cooling mode
 
Forced air cooling
Degree of protection
 
IP21/IP20
Working altitude
 
0 ~ 3000m (> 2000m, need to reduce capacity)
Reactive power regulation range
 
Continuously adjustable from rated capacitive reactive power to rated inductive reactive power
harmonic
 
Meet the requirements of power quality and harmonics in the public power grid (GB/T 14549-93)
response time
 
3ms
display
 
TFT true color touch screen, real-time voltage, and current data display
Intelligent communication
 
TCP/IP GPRS Modbus
Storage, transportation, temperature-40~70ºCC
Reliability and life
 
Design life 20 years
electromagnetic compatibilityComply with GB 7251-2005 (GB 7261-2000)

Remarks:
1. The unit incoming line mode is divided into forwarding line type and backward line type, which can be selected;
2. The product specifications and parameters of the above SVG models may change due to different on-site working conditions or      actual needs of users;
3. The matching relationship in the table is not unique. Users can choose by themselves according to the application conditions.
4. Due to different options, the size of the SVG cabinet may change;
5. Single-phase installation with a width less than 1200mm (included).


International Standards and specifications
  • Standard voltage level (3 / 3.3 / 4.16 / 6 / 6.6 / 10 / 11KV)
  • Global standards ISO
  • Environmental requirements (RoHS index, limiting the use of certain hazardous substances in electronic and electrical equipment)
  • GB/T 19001-2016 idt ISO9001: 2015
    ISO 45001:2018
    GB/T 24001 -2016 idt ISO14001: 2015
    AAA credit rating
    Test standards:
    EN IEC 61800-3: 2018
    EN 61000-3-12: 2011
    EN 61000-3-11: 2000



Company Profile


Other products we manufacture

 
Application fields


FAQ
Q1: Are you a trading company or manufacturer?
We are a factory.

Q2: How long is your lead time?
It depends on the solution you require but generally 25-60 days. For more specific information, please don't hesitate to ask us

Q3: Do you provide samples? is it free or extra?
Yes, we provide samples and we charge for the samples and the freight cost.
 
Q4. How to ensure product quality? 
Our production strictly follows the ISO9001 quality control system. We give the green (pass) sign only when we finish several quality inspections and high-temperature high-pressure tests


Q5 How about your payment and shipment?
Payment: We accept T/T, LC, Western Union, PayPal, Alipay, etc. terms of payment.


Q7. Do you provide a warranty for the goods? And what are the terms of the warranty?
Yes, we provide 12 months warranty for all the goods. Please, contact us for information regarding warranty, technical support, and any other questions

Product Tag:
Related categories: