Fluke 725ex Intrinsically Safe Multifunction Process Calibrator

Min.Order: 1
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 5200 ~ 5400

Description
Source and measure most process parameters such as mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure using optional pressure modules (sold separately) with this process calibrator. It is intrinsically safe for use in explosion endangered areas. Additionally, it features auto-stepping and auto-ramping.
 

Other useful features:

  • Pressure switch test function to capture set, reset, and deadband values
  • Small, streamlined shape, and rugged, reliable design that stands up to field use
  • Simple, push-button user interface for easy operation
  • Provides two-channel simultaneous source and measure capability to calibrate transmitters
  • Powers transmitters during test using loop supply
  • Stores frequently-used test setups for later use
  • Measures pressure to 3,000 psi/200 bar using any of the eight intrinsically safe Fluke 700PEx Pressure Modules to calibrate pressure transmitters and I/P devices
Product Parameters

 

Measurement Accuracy
Voltage DC30.000 V: 0.02% + 2 counts (upper display)
10.000 V: 0.02% + 2 counts (lower display)
90.00 mV: 0.02% + 2 counts
-10.00 to 75.00 mV: 0.025% + 1 count (via TC connector)
Current DC24.000 mA: 0.02% + 2 counts
Resistance0.0 to 400.0 Ω: 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire)
401 to 1500 Ω: 0.5 Ω (4-wire), 1 Ω (2- and 3-wire)
1500 to 3200 Ω: 1 Ω (4-wire), 1.5 Ω (2- and 3-wire)
Frequency2.0 to 1000.0 CPM: 0.05% + 1 count
1.0 to 1100.0 Hz: 0.05% + 1 count
1.00 to 10.00 kHz: 0.05% + 1 count
Sensitivity: 1 V peak-to-peak-minimum
PressureAccuracy from 0.025% of range using any of 8 intrinsic safe pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
Source Accuracy
Voltage DC100.00 mV: 0.02% + 2 counts
10.000 V: 0.02% + 2 counts
-10.00 to 75.00 mV: 0.025% + 1 count (via TC connector)
Current DC24.000 mA (source): 0.02% + 2 counts
24.000 mA (simulate): 0.02% + 2 counts
Resistance15.0 to 400.0 Ω: 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA)
401 to 1500 Ω: 0.5 Ω (excitation current 0.05 to 0.8 mA)
1500 to 3200 Ω: 1 Ω (excitation current 0.05 to 0.4 mA)
Frequency2.0 to 1000.0 CPM: 0.05%
1.0 to 1100.0 Hz: 0.05%
1.00 to 10.00 kHz: 0.25%
Waveform: 5 V p-p squarewave, -0.1 V offset
RTDs and Thermocouples
Measure AccuracyNI-120: 32.36°F (0.2°C)
PT-100 (385): 32.6°F (0.33°C)
PT-100 (393): 32.54°F (0.3°C)
PT-100 (JIS): 32.54°F (0.3°C)
PT-200 (385): 32.36°F (0.2°C)
PT-500 (385): 32.54°F (0.3°C)
PT-1000 (385): 32.36°F (0.2°C)
Resolution: 0.1°C
J: 33.26°F (0.7°C)
K: 33.44°F (0.8°C)
T: 33.44°F (0.8°C)
E: 33.26°F (0.7°C)
R: 35.24°F (1.8°C)
S: 34.7°F (1.5°C)
B: 34.52°F (1.4°C)
L: 33.26°F (0.7°C)
U: 33.35°F (0.75°C)
N: 33.62°F (0.9°C)
Resolution: J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
XK: 33.08°F (0.6°C)
BP: 34.16°F (1.2°C)
Source AccuracyNI-120: 32.36°F (0.2°C)
PT-100 (385): 32.6°F (0.33°C)
PT-100 (393): 32.54°F (0.3°C)
PT-100 (JIS): 32.54°F (0.3°C)
PT-200 (385): 32.36°F (0.2°C)
PT-500 (385): 32.54°F (0.3°C)
PT-1000 (385): 32.36°F (0.2°C)
Resolution: 0.1°C
Accuracy stated for 4-wire measurement.
J: 33.26°F (0.7°C)
K: 33.44°F (0.8°C)
T: 33.44°F (0.8°C)
E: 33.26°F (0.7°C)
R: 34.52°F (1.4°C)
S: 34.7°F (1.5°C)
B: 34.52°F (1.4°C)
L: 33.26°F (0.7°C)
U: 33.35°F (0.75°C)
N: 33.62°F (0.9°C)
Resolution: J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C
XK: 33.08°F (0.6°C)
BP: 34.16°F (1.2°C)
Functions Specifications
Ramp FunctionsSource functions: Voltage, current, resistance, frequency, temperature
Ramps: Slow ramp, Fast ramp, 25% step-ramp
Loop Power FunctionVoltage: 12 V
Accuracy: 10%
Maximum current: 22 mA, short circuit protected
Step FunctionsSource functions: Voltage, current, resistance, frequency, temperature
Steps: 25% of range, 100% of range
Mechanical and General Specifications
Batteries4 x AA alkaline batteries
Battery ReplacementSeparate battery compartment, accessible without breaking calibration seal
Side Port ConnectionsPressure module connector
Dimensions5.188 x 9.291 x 2.402" (130 x 236 x 61 mm)
Weight1.874 lbs (0.85 kg)
  

 

Fluke 725Ex

  • Intrinsically safe multifunction process calibrator
  • Meets I.S. Class I, Division 1 Groups B-D, 171°C compliance standards
  • Measures volts DC, mA, RTDs, thermocouples, frequency, and ohms
  • Sources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohms

The Fluke 725Ex is an intrinsically safe multifunction process calibrator for use in explosion-endangered areas. It is powerful, yet easy to use. Combine the 725EX with any of the eight Fluke 750PEx Pressure Modules (sold separately), and you'll be able to calibrate almost any process instrument likely to need service in an area where explosive gasses may be present.

The 725EX sources and measures almost all process parameters including mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure, using optional pressure modules. Its split display lets you view input and output values simultaneously to calibrate transmitters. For valve and I/P tests, you can source mA while measuring pressure. The 725Ex has auto-stepping and auto-ramping for remote testing, plus 25% stepping for fast linearity tests.

From the moment you pick it up, the Fluke 725Ex is ready to perform. Its simple controls, without menus, make operation easy. Its memory functions make set up fast. And its rugged design lets it work as hard as you do.

 