Apm Series RS485 Communication Multi Rate Panel Power Meter

Min.Order: 1
Product origin: Shanghai, China
Infringement complaint: complaintComplaint
US$ 518

Description

Overview

 

Overview

     

APM series power meters of ACREL are power meters that are designed according to IEC standards and synchronized with
international advanced technology.
APM series meters have full power measurement, energy statistics, analysis of power quality and network communications and
other functions, are mainly used for comprehensive monitoring of the quality of power supply network.
This series of meters use a modular design, with a rich function of the external DI / DO module, AI / AO module, event recording
(SOE) module with T-Flash (TF) card, network communication module, Temperature and humidity measurement module, can
achieve full power measurement of electrical circuit and monitoring of switch status, Dual RS485 with Ethernet interface can realize data copying of RS485 master station, eliminating the need for data switching exchange. PROFIBUS-DP interface can realize
high-speed data transmission and networking function.

Product Parameters

Technical ParametersIndex
SignalElectrical networkThree-phase three-wire, three-phase four-wire, see the wiring diagram;
Frequency45~65Hz;
VoltageRated value:AC 100V,110V,400V,690V;
Overload: 1.2 times rated value(continuous); 2 times rated value /1 second;
Power consumption: < 0.5VA (per channel);
CurrentRated value: AC 1A, 5A, support 4 mm2 line access;
Overload: 1.2 times rated value(continuous); 10 times rated value/1 second;
Power consumption: < 0.5VA (per channel);
Measurement accuracyVoltage,current and powerclass 0.5s/class 0.2s (APM800,APM810/APM801)
Active powerclass 0.5s/class 0.2s (APM800,APM810/APM801)
Reactive powerclass 2
Harmonic1%(2rd~42nd),2%(43rd~63rd)
Switch inputsDry contact inputs, built-in power supply;
Relay outputsContact type: open contact in main part, changeover contact in module;
Contact capacity:AC 250V/3A  DC 30V/3A;
Pulse output of energyOutput mode: Optocoupler pulse with open collector;
Pulse constant:4000(5A),8000(1A) imp/kWh;
Analog outputsDC 0mA~20mA,4mA~20mA,0V~5V,1V~5V output, accuracy class 0.5%, load resistance ≤ 500Ω;
Analog inputsDC 0mA~20mA,4mA~20mA,0V~5V,1V~5V iutput, accuracy class 0.5%
Storage cardStandard Capacity:4G,TF Card Up to 32G Capacity;
CommunicationRS485 interface/Modbus-RTU protocol and DLT645 protocol
Profibus-DP interface/Profibus-DP protocol;
RJ45 interface (Ethernet) / Modbus-TCP, http, DHCP and other protocols;
Power supplyWorking range: AC/DC 85V~265V or AC/DC 115~415V(P2);
Power consumption: Power consumption of the main part ≤ 15VA;
SafetyPower frequency withstand voltageThe power frequency withstand voltage between the shell and the auxiliary power supply, each input and output terminal group is AC 4kV/1min;
The power frequency withstand voltage between the auxiliary power supply and each input and each output terminal group is AC 2kV/1min;
The power frequency withstand voltage between the voltage input and other input/output terminal groups is AC 2kV/1min;
The power frequency withstand voltage between the current input and other input/output terminal groups is AC 2kV/1min;
The power frequency withstand voltage between the relay output and other input/output terminal groups is AC 2kV/1min;
The power frequency withstand voltage between each terminal group of switch input, communication, analog output and pulse output is AC 1kV/1min;
Insulation resistanceInputs,outputs to the shell>100MΩ;
Electromagnetic compatibilityMeet IEC 61000 standard (Level 4);
Protection levelDisplay panel IP52
EnvironmentOperating temperature: -20 °C ~ +65 °C;
Storage temperature: -20°C~+70°C;
Relative humidity: ≤95% without condensation;
Altitude: ≤2500m;
StandardsIEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
Environmental Testing-Part 2-1:Tests Test A:Cold IDA
Part 2-1:Tests Test B:Dry heat
Part 2-30:Tests Test Db:Damp heat,cyclic(12+12h)
IEC 61000-4Electromagnetic compatibility-Testing and measurement techniques
IEC 61557-12Electrical safety in low voltage distribution system up to 1000V a.c. and1500V d.c -Equipment for testing,measuring or monitoring of protective measures- Part12:
Performances measuring and monitoring devices(PMD)
 IEC 62053-22Electricity metering equipment (a.c.)-Particular requirements - Part22:Static meter for active energy(class 0.2s and 0.5s)
 
FunctionAPM800
(class 0.5s)
APM801
(class 0.2s)
APM810
(class 0.5s)
Measured parametersTotal electrical measurement
Four-quadrant energy
Pulse output of energyPulse output of active/reactive energy
DemandThree-phase current, active power, reactive power, real-time demand of apparent power, and maximum demand (including time stamp)
Extreme value statisticsExtremum of current, line voltage, phase voltage, active power, reactive power, apparent power, power factor, frequency, total harmonic of current, total harmonic of voltage in this month and last month (including time stamp)
Power qualityUnbalance of current, line voltage, phase voltage
Voltage phase angle, current phase angle
Voltage current phase Angle
Total (odd, even) harmonic content of voltage and current××
Harmonic content of voltage and current (2-63 times)××
Voltage crest factor××
Telephone waveform factor××
Current K-factor××
Alarm recordsA total of 66 kinds of alarm types, each type can record the most recent 16 alarm records, support extended records by TF card
Event logRecord the most recent 128 event records, support extended records by TF card
CommunicationModbus protocol
I/O2 digital inputs + 2 digital outputs (2DI+2DO)
ExtensionsMD828 digital inputs + 2 digital outputs with changeover contacts (8DI+2DO)
MLOGTF card storage (alarm records, event records, electrical parameters and energy timing records, etc.)
MA848 analog inputs (class 0.5) + 4 analog outputs (class 0.5) (8AI+4AO)
MCM1 RS485/Modbus-RTU, support master mode or slave mode
MCP1 Profibus-DP
MCE1 Ethernet, support Modbus-TCP, http, SMTP, DHCP protocol
 MTH4 ways of temperature measurement, 1 way of temperature and humidity control
 

Dimension

 

Dimension
 

Wiring

 

Wiring
 
About Acrel
Product Tag:
Related categories: