Electric Power Meter Smart Electricity Meter Rogowski Coil Electrical Measuring Instrument

Min.Order: 1
Product origin: Shanghai, China
Infringement complaint: complaintComplaint
US$ 200 ~ 300

Description
 
Technical consultant
                                                                                                                                                                   Susan 
 
 

1   Product description

MQ21, the power quality analyzer externally connected with open type Rogowski coil or voltage CT, it can realize no dismantling wire test, facilitate engineering test, simplify test steps, save construction cost, and is also more convenient for the inspection and maintenance of distribution system. MQ21 supports systems of single-phase and three-phase: it can measure multiple electrical parameters such as voltage, current, harmonic, energy, power factor and active power on the power grid of phase A, B, C and phase N. With standard configuration of RJ45 and RS485 communication interfaces, through standard Modbus TCP and Modbus RTU protocols, it can be compatible with various configuration systems and transmit the electrical parameters collected by the front end to the system data center in real time.
 
Description
Model No.MQ21
TypeThree phase power quality analyzer
Supported types of current sensorRogowski coil, Voltage-output current clamp
Wiring mode3ф_WYE_4CT, 3ф_WYE_3CT, 3ф_DELTA_3CT,3ф_DELTA_2CT,1ф
Storage16GB Micro SD card,USB data download
(default storage interval: 1 minute)
Harmonic51 times 
Applicationpower analysis,  energy measurement
Display screen1.3-inch color OLED
WeightApprox 400g
DimensionL*W*D:13*9.5*5.6CM
ColorWhite
Input current
Primary side current range600A       0.5A ~ 720A
3kA        0.5A ~ 3600A
6kA        0.5A ~ 7200A
Secondary side current range(ST08  current clamp or the same type)1mA~10A
Input voltage value1/225mV~707mV
Overload capacity2V,10s/hours
Power supply
Electric sourceElectricity from major loop, 90~528VAC
External batteryExternal 18650 lithium battery
Power consumption
Max power consumption2.5W
Connecting terminal type
ABC phase current inputSATA interface
N-phase current input5.08 terminal
Voltage input7.62 spacing terminals
Power supplyElectricity from major loop, 90~528V

2   Function

Measurement
VoltageUA,UB,UC,and average value
CurrentIA,IB,IC,IN and average value
PowerActive power, reactive power, apparent power (each phase, sum value of three phases)
energyActive energy, reactive energy, apparent energy(each phase, sum value of three phases)
Exceeds 999.9GWh, energy value cleared to "0" automatically
Line voltageBetween phases
Angle between line voltagesBetween phases
Angle between currentsBetween phases
Power factorIncluding harmonic power factor PF and fundamental power factor DPF(each phase, average value of three phases)
Max / Min.
VoltageEach phase, average value of three phases
CurrentEach phase, average value of three phases
PowerActive power, reactive power, apparent power(each phase, sum value of three phases)
Unbalance degree
VoltageEach phase, the max unbalance degree of three phases       
CurrentEach phase, the max unbalance degree of three phases       
Demand / Max Demand
CurrentEach phase, average value of three phases
PowerActive power, reactive power, apparent power(each phase, sum value of three phases)
Temperature and humidity
Temperature3 channels(optional)
Humidity1 channel
Power quality
Voltage swellStart time, end time, amplitude value
Voltage dipStart time, end time, amplitude value
Voltage harmonic value and percentageTotal harmonic, 1, 2, 3, 4... 51 (51st) harmonics
Current harmonic value and percentageTotal harmonic, 1, 2, 3, 4... 51 (51st) harmonics
 
General data record
Record interval setting5 ~ 9999s (default 60s)
Data formatCSV
Storage capacityMicro SD card: 16GB
Storage duration: 3 years (using 16GB SD card, once / 60s)
Recorded dataBasic data
Voltage harmonic
Current harmonic
Event data record
Data formatCSV
Recorded dataEvent type
Start time
Duration
Amplitude value
Voltage RMS 1 / 2 value of each phase
Voltage waveform of each phase

3   Accuracy and certification

Measurement accuracy
Rogowski coilCurrent measurement accuracy0.5%(1%~120% rated current)
(<10A, accuracy not guaranteed)
Current gear600A(6A~720A): TRC-36 (50mV/kA@50Hz)
3000A(10A~3600A): NRC-150 (85mV/kA@50Hz)
6000A(20A~7200A): NRC-200 (50mV/kA@50Hz)
ST08 current clampCurrent measurement accuracy0.5%(100mA~10A)
1%(10mA~100mA), (<10mA, accuracy not guaranteed)
ABC Voltage measurement accuracy0.2%(5~528V AC)
Power factor±0.005
Active and apparent powerIEC62053-22  Class 0.5S
Reactive powerIEC62053-21  Class 2S
Frequency0.01%(45~65Hz)
Active energyIEC62053-22  Class 0.5S
Reactive energyIEC62053-21  Class 2S
Environment condition
Operating temperature-25ºC~+55ºC
Storage temperature-40ºC~+85ºC
Humidity range5~95% RH, 50ºC (non-condensing)
Pollution Level2
Overvoltage capacityIII, applicable to the distribution system below 277/480VAC
Insulation strengthIEC61010-1
Altitude3000m Max
Anti-pollution levelIP20(conforming to IEC 60629)
Products expiry24 months
EMC(Electromagnetic compatibility)
Electrostatic dischargeLevel IV(IEC61000-4-2)
Radiation ImmunityLevel III (IEC61000-4-3)
EFT Electrical Fast Burst ImmunityLevel IV (IEC61000-4-4)
Surge immunityLevel IV (IEC61000-4-5)
Immunity to Conducted DisturbanceLevel III (IEC61000-4-6)
Power frequency magnetic field immunity0.5mT (IEC61000-4-8)
Conduction and radiationClass B (EN55022 )
Standard compliance
EN 62052-11, EN61557-12, EN 62053-21, EN 62053-22, EN 62053-23, EN 50470-1, EN 50470-3, EN 61010-1, EN 61010-2, EN 61010-031

4   Outline and dimensions

5   Port definition

MQ21 is equipped with abundant interfaces to realize different functions.

5.1   Power supply

MQ21 is powered directly through ABCN voltage channel. The power supply voltage range: 90~528VAC, 45~60Hz, Mam power consumption 2.5W.
  • Do not connect the analyzer when the cable is live;
  • Before connecting the power supply, be sure to confirm whether the power supply voltage is within the required range, otherwise the analyzer cannot work normally.

5.2   Voltage current input

The analyzer supports 5 wiring modes: 3ф_WYE_4CT, 3ф_WYE_3CT, 3ф_DELTA_3CT, 3ф_DELTA_2CT, Single phase.
 
  • The actual wiring mode of the analyzer must be consistent with the one configured inside the analyzer.
  • 3ф_WYE_4CT need 4pcs current sensor, and N-phase current can be measured.
  • 3ф_WYE_3CT need 3pcs  current sensor, N-phase current cannot be measured.
  • 3ф_DELTA_3CT need 3pcs current sensor, phase B current is acquired by sensor actual measurement.
  • 3ф_DELTA_2CT need 2pcs current sensor, phase B current is acquired by calculating.
  • The phase sequence of voltage and current must correspond one by one, otherwise the measured data of the analyzer is incorrect.
  • When using the current sensor, note that the direction of the current arrow on the sensor must be consistent with the actual current flow, that is, the sensor current arrow points to the load end.
 
For more information, please refer to MQ21 manual. 

 



 