Skz1052b Rt~ 550c 0.001c Oxidation Induction Time (OIT) Melting Point DSC Differential Scanning Calorimeter

Min.Order: 1
Product origin: Jinan, Shandong, China
Infringement complaint: complaintComplaint
US$ 5225 ~ 5500

Description
DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control. DSC research and development includes the following field: glass transition temperature, melting point, cold crystallization, crystallization, phase transition, oxidation induction time (OIT).

Standards:
ISO/TR10837:1991, ASTM D3895-1998, ASTM E 967, ASTM E 968, ASTM E 793, ASTM D 3895, ASTM D 3417, ASTM D 3418, ISO 11357-6

Main Features:
1. The industrial-grade 7-inch touch screen displays user friendly.

2. Brand-new metal furnace body structure, with better baseline and higher accuracy. The heating adopts indirect conduction  method, which has high uniformity and stability, reduces pulse radiation, and is better than traditional heating mode.
3. USB communication interface, strong versatility, reliable and uninterrupted communication, supports self-recovery connection function.
4. Automatically switch the two-channel atmosphere flow, fast switching speed and short stabilization time. At the same time, a protective gas input is added.
5. The software is simple and easy to operate.

Technical parameters:
Temperature rangeRT~ 550 ºC 
Heating rate0.1~80ºC/min
Temperature resolution0.001ºC
Temperature fluctuations±0.001ºC
Temperature repeatability±0.1ºC
Constant temperature timeProgram setting 24h
DSC range0~±600mW
DSC noise0.01μW
DSC resolution0.01μW
DSC accuracy0.01mW
Atmosphere control gasNitrogen, Oxygen (instrument switch automatically)
Gas flow rate0-300mL/min
Gas pressure0.2MPa
Control ModeRising temperature, constant temperature(full automatic)
Curve scanningRising scan
Gas flow controlBuilt-in digital flow meter & Software control, automatic
Display 24 bit 7 inches LCD touch screen display
Data interfacestandard USB connector
Parameter standardWith standard material, with calibration function, the user may correct temperature and heat enthalpy
SoftwareProfessional control operating software
Thermocouples Total 3 sets of thermocouples for:
1). Test sample temperature
2). test furnace temperature,
3). Test internal ambient temperature
Cooling device  
Power AC220V/50Hz

Packing List
Host instrument1PC
CD1PC
Data Line1PC
Power Line1PC
Aluminum crucibles100PCS
Ceramic crucibles100PCS
pure tin grains1bag
Fuse 4A5PCS