Hach QP1680 High-Temperature TOC Laboratory Analyzer, with auto sampler, 65 positions

The QP1680 Analyzer measures Total Organic Carbon (TOC) and Total Nitrogen (TNb) in one sample.

The QP1680 is available as a combined TOC and TNb analyzer or for the individual parameters TOC or TNb.
The most important features include:
• Direct sample injection eliminates sample contact with valves and the built-in injection syringe, which minimizes the risk of sample carry-over.
• Large diameter sample aspiration tubing can handle particles up to 800 µm, expanding possible applications and reducing clogging.
• Integrated stirrer for each sample position homogenizes particle-containing samples before injection.
• Small footprint with integrated 65-position auto-sampler requires less space in the laboratory (an auto-sampler with 96 positions is also available as an alternative).
• Simple operation, data analysis and system diagnosis thanks to an intuitive software package.
 

Specifications

 

 
Technical Attributes
Ambient Temperature-20 - 60 °C
Analysis timeApprox. 3 minutes
Dimensions440 mm x 380 mm x 700 mm (H x W x D)
Gas consumption150 mL/min*

*Sample preparation for NPOC determination requires additional 300-350 mL/min.
Gas specificationsOxygen or synthetic air: minimum 99.998% (4.8) at 3 - 10 bar
Lower Limit of Detection (LOD)TC, TOC, NPOC: 50 µg/L
Measurement MethodNDIR (non-dispersive Infrared Detection)
ModelQP1680-TOC
Norms and StandardsTOC / NPOC: ASTM D7573, EN 1484, EPA 415.1, EPA 9060A, ISO 8245, SM 5310B, NEN-ISO 20236
Number of sample positions65
Operating Conditions20 - 30 °C; 20 - 80% relative humidity (non-condensing)
Oxidation MethodCatalytic combustion at 680 °C
ParameterTOC
Pollution Degree2
PowerAnalyzer: 750 W max.
PC: 90 W max.
Monitor: 100 W max.
Power SupplyAnalyzer: 100 - 240 VAC, 50/60 Hz, 16 A, with protective grounding
PC: 100 - 240 VAC, 50/60 Hz, 1.6 A, with protective grounding
Monitor: 100 - 240 VAC, 50/60 Hz, 1.6 A, with protective grounding
RangeTC, TIC, NPOC: 0 - 30000 mg/L
RepeatabilityUp to 10 mg/L TC, TIC, NPOC, TN: < 5%
> 10 mg/L TC, TIC, NPOC, TN: < 2%
Sample Volume10 - 1000 µL
TemperatureFurnace temperature max. 1050 °C (depending on configuration)
WeightApprox. 31 kg
What's included?TOC Instrument
Sample tray with 65 positions for 40 mL vials
Glass sample vials 40 mL (100 pcs)
USB 2.0 cable A-B
Set of tubing PTFE blue-stripe 1/8" OD length 2 m including nut & ferrule
Reagent container with screwcap for UPW, Acid and Waste
Power cord
USB storage device with software, test results and Full User Manual
Printed User Manual