Range | 20m |
Blind area | 0.2-0.5m |
Error | 0.3%F.S |
Display | Four eight-section 0.36in LED(Optional LCD) |
Minimum display resolution | 1mm |
Keyboard | Three-position SMT key |
Working frequency | 20-350KHz |
Optional power supply | DC24V |
Power consumption | <1.5W |
Instrument material | ABS engineering plastics |
Installation interface | G1 1/2Pipe thread with large gong ring or M60*2 |
Electrical interface | PG7 |
Into the wire cable | 0.5m or customized |
Working environment | -20~80ºC Atmospheric pressure |
Protection grade | IP65 or customized |
Output way | 4~20mA RL>600Ω or customized |
Product Advantages
1:Anti-interference filtering
2:Arbitrary setting of full-scale starting point and focus
3:Digital filtering and echo recognition
4:Can manually set fixed interference filtering function
5:Support custom serial data format
6:More accurate measurement
7:With value-added / difference ranging options, both distance and object can be measured
8:With 1-15 level transmission pulse intensity can be set according to the working conditions
Installation method