Hikins 3013 High Flow 400 500 600gpd Domestic RO Reverse Osmosis Membrane

Min.Order: 500
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 11.1 ~ 12.1

Description
Hikins 3013 High Flow 400 500 600GPD Domestic RO Reverse Osmosis Membrane
Product Description

Hikins is the largest residential RO membrane, commercial RO membrane, industrial RO membrane manufacturer in South China providing OEM service for high quality and stable performance RO membranes, With its own flat-sheet production line, Hikins has developped full range of RO membrane production for tap water, for surface water, for underground water, and for brackish water as well as sea water RO membrane.

Benefits:
1) Reverse Osmosis removes up to 98% of total dissolved solids.
2) Hikins RO membranes deliver healthier and safer drinking water by reducing concentrations of Arsenic, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper, Turbidity, Fluoride, Lead, Radium 226/228, Selenium, and TDS.
3) Hikins RO membrane is made with thicker RO membrane element, and with easier and effective rinsing and cleaning output.
4) Hikisn RO membrane uses wider feed spacer which ensures the performance of the RO system.
5) Hikins RO membrane is rolled on full automatic Rolling machine.

Specification
Model NO.Hikins-3013-500
Active Area18.3Ft2 (1.7m2)
Removal Rate96%
Film Body Size305*68*68mm
Water Rroduction Rate500GPD
Working Pressure80PSI
Packing Quantity16PCS/CTN
Packing Size320*320*360mm
Gross Weight9KGS
Detailed Photos

* "FEY" is a sub-brand of "Hikins"
 

Product Parameters

SeriesModelActive AreaSalt RejectionWater OutputTest Prssure
Ft2(m2)%GPDPSI
15101510-502(0.17)975065
1510-753(0.25)977565
ECO1812-50 9L3.5(0.35)975065
1812-75 9L3.5(0.35)977565
238mm1812-50 13L4(0.4)975065
1812-75 13L4(0.4)977565
2012-100 13L5(0.5)9710065
4000ppm1812-754(0.4)9575120
2012-804.5(0.45)9680120
2012-1005(0.5)96.5100120
Regular
1812/2012
2000ppm
1812-50 11L4(0.4)975065
1812-75 11L4(0.4)977565
2012-80 12L4.5(0.45)978065
2012-100 13L5(0.5)9710065
2012-125 13L5.2(0.52)9712565
2012-1506(0.6)9715065
2012-18010(1.0)9718065
2012-2007.5(0.7)9720065
SeriesModelActive AreaSalt RejectionWater OutputTest Prssure
Ft2(m2)%GPDPSI
30123012-2008.6(0.8)9720065
3012-25010.8(1)9725065
3012-30013(1.2)9730065
3012-40015(1.4)9740080
3012-60020.5(1.9)9660090
30133013-40015(1.4)9740080
3013-50018.3(1.7)9650080
3013-60020.5(1.9)9660090
32133213-60020.5(1.9)9660090
3213-80026(2.5)9680090
34133413-80028(26)9680090
3413-100032(3)95100090
Inline RO1812-754(0.4)9750/75/10065

 

Installation Instructions

Installation Instructions


Unscrew the nut on the membrane shell cover at the inlet water connection end, take out the inlet water pipe, then use the membrane shell wrench to loose the membrane shell cover. Take the RO membrane from its packaging, put the end of the membrane with 2 O-rings into the RO membrane shell (See The following Diagram ) and push it in, finally screw the membrane shell cover back on, and tighten it with membrane shell wrench, put the inlet water pipe back into the inlet water connector and screw the nut tightly, then push the membrane shell card into the large single clip.



Direction For Use
 

1.When installing the RO membrane, you should pay attention to the direction of the membrane;

2. When installing the RO membrane, you should first make sure that one end of the membrane has 2 O-rings;

3. When installing, be sure to put the end with the O-ring into the end of the membrane shell with the pure water connection, for correct installation you need only a little force to put the RO membrane into the membrane shell, if you encounter too much resistance, please do not force the membrane into the shell, or it could lead to permanent damage to the membrane shell or membrane components (the membrane manufacturer does not take the responsibility for replacing components due to damage made during installation);

4. Damage to the membrane shell and membrane element caused under above mentioned situation is not covered by the warranty.

Company Profile




Our Advantages

A. Full range RO membranes 50GPD to 1000GPD for home use.
B. Self-produced membrane sheet.
C. Each roll of membrane sheet will be tested before bulk production.
D. Each finished membrane will need pass vacuum testing, to make sure salt rejection rate.
E. OEM and ODM orders are welcomed.

FAQ

FAQs on Reverse Osmosis RO membrane OEM manufacturing
 

Q1: What type of RO membrane is avaliable in your company?

A1: In general, Hikins has Domestic RO membrane and Industrial RO membrane, For Domestic RO membrane, Hikins has Municipal Tap water RO membrane, Rural Area Under Ground water RO membrane, High-flow Low pressure RO membrane, and Brackish water RO membrane. For Industrial RO membrane, Hikins has Low Pressure Engergy saving RO membrane, BW Brackish water desalination RO membrane, FR Fouling Resistant RO membrane, as well as XLE Extreme Low Pressure RO membrane, and High Salinity Brackish Water Desalination RO membrane.

 

Q2: What is Salt Rejection Ratio?

A2: The Salt rejection describes the quality of salt removed from the Reverse Osmosis feed water stream as a percentage. It's one of the key element of the RO membrane quality, however, other essential elements such as RO membrane performance durability, stability, application scope in different region, and permeate flow output at the same pressure will all be the important factors to judge the quality of the membrane.

 

Q3: Is the Salt reation of the RO membrane the higher the better?

A3: This will be depending on the feed water quality, if the feed water quality is good, even a 90% salt rejection membrane will be workable, if the feed water is with bad quality and with brackish water environment, a higher salt rejection above 95% is an ideal choice. For any membrane that meet the local drinking water standard will be a good membrane.

 

Q4: Is there are any other element we need to take into consideration when selection the RO membrane?

A4: Yes, the pre-treatment filter cartridge and pre-treatment system will affect the RO membrane performance as well, please select good quality filters and pre-treatment system.

 

Q5: Why there are white foam-like water being in the treated water at the initial usage?

A5: To preserve the RO membrane for a long shelf-life, and prevent the membrane from being oxydized, a water soluble protection material is coated on the surface of the membrane, which will be rejected in both the rejected water and treated water, for initial use, both rejected water and treated water should be rejected and the the RO membrane should be thourghly cleansed. The treated water at initial use shall not be injected to the water storage tank.

 

Q6: Why there are bublles in the treated water?

A6: Oxygen and Nitrogensand carbon dioxide is water soluble in the molecular form, during the water filtration process in the Reverse Osmosis process, those air will be released due to the pressure change between input water and output water. Those air is not harmful, just like Coca-cola.

 

Q7: Why dry RO membrane has a salt rejection rising process from its initial usage?

A7: The performance of the RO membrane is strictly conencted to the wetness of the membrane, when the membrane is wet, it will reach to ts maximum performance, dry membrane has a process to become wet from its initial usage. Make sure that the membrane hsould be rinsed after each usage.

 

Q8: Why Active carbon filter is requested for RO membrane?

A8: Chloride and chlorine content is harmful from the feed water, RO membrane is easily to be damaged as the surface of the RO membrane will be easily being oxydized.

Product Tag:
Related categories:
Scroll to Top