Strong Acid Alkali Resistance Chemistry Fume Hood for Laboratory

Min.Order: 1
Product origin: Chengdu, Sichuan, China
Infringement complaint: complaintComplaint
US$ 15500 ~ 21500

Description

 
Product Description

A fume hood is typically a large piece of equipment enclosing five sides of a work area, the bottom of which is most commonly located at a standing work height.

Two main types exist, ducted and recirculating (ductless). The principle is the same for both types: air is drawn in from the front (open) side of the cabinet, and either expelled outside the building or made safe through filtration and fed back into the room. This is used to:

  • protect the user from inhaling toxic gases (fume hoods, biosafety cabinets, glove boxes)
  • protect the product or experiment (biosafety cabinets, glove boxes)
  • protect the environment (recirculating fume hoods, certain biosafety cabinets, and any other type when fitted with appropriate filters in the exhaust airstream)

Most fume hoods for industrial purposes are ducted. A large variety of ducted fume hoods exist. In most designs, conditioned (i.e. heated or cooled) air is drawn from the lab space into the fume hood and then dispersed via ducts into the outside atmosphere.

The fume hood is only one part of the lab ventilation system. Because recirculation of lab air to the rest of the facility is not permitted, air handling units serving the non-laboratory areas are kept segregated from the laboratory units. To improve indoor air quality, some laboratories also utilize single-pass air handling systems, wherein air that is heated or cooled is used only once prior to discharge. Many laboratories continue to use return air systems to the laboratory areas to minimize energy and running costs, while still providing adequate ventilation rates for acceptable working conditions. The fume hoods serve to evacuate hazardous levels of contaminant.

To reduce lab ventilation energy costs, variable air volume (VAV) systems are employed, which reduce the volume of the air exhausted as the fume hood sash is closed. This product is often enhanced by an automatic sash closing device, which will close the fume hood sash when the user leaves the fume hood face. The result is that the hoods are operating at the minimum exhaust volume whenever no one is actually working in front of them.

 
Product Parameters
 
               Model Specification  WJ-1500AWJ-1500BWJ-1800AWJ-1800B
External dimensions of equipment(mm)1500(W)*1205 (D) *2400 (H)1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm)1260(W1)*780(D1) *1100 (H1)1560(W1)*780(D1) *1100 (H1)
Panel material20+6mm thick butterfly ceramics
Material of internal lining board5mm thick ceramic fiber board
Diversion structureLower air return
Control systemButton control panel (LCD panel)
PH value controlThe medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input powerThree-phase five-wire 380V/50A
Current for air fanNot over 2.8A(380V or 220V can be directly connected)
Maximum load of socket12 KW(total of 4 sockets)
Water tap1 set (remote control valve water nozzle)No1 set (remote control valve + water nozzle)No
Water discharge wayMagnetic chemical pump strong discharge
Using environmentFor non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fieldsInorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of PurificationSpray sodium hydroxide solution, no less than 8 cubic meters/hourSpray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed controlManual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm)0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface airNot higher than 10%
The average intensity of illuminationNot less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
NoiseWithin 55 decibels
Flow displayWhite smoke can pass through the exhaust outlet, no overflow.
Safety inspectionNo spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinetLess than 160 pa
Power consumptionLess than 1.0kw/h (excluding power consumption of fans and external instruments)Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumptionLess than 3.2L/ hLess than 4.0L/ h
Performance of wind compensationWith a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
Specialty Designs

Acid digestion

These units are typically constructed of polypropylene to resist the corrosive effects of acids at high concentrations. If hydrofluoric acid is being used in the hood, the hood's transparent sash should be constructed of polycarbonate which resists etching better than glass. Hood ductwork should be lined with polypropylene or coated with PTFE (Teflon).

Downflow

Downflow fume hoods, also called downflow work stations, are typically ductless fume hoods designed to protect the user and the environment from hazardous vapors generated on the work surface. A downward air flow is generated and hazardous vapors are collected through slits in the work surface.

Perchloric acid

These units feature a waterwash system (scrubber - see below) in the ductwork. Because dense perchloric acid fumes settle and form explosive crystals, it is vital that the ductwork be cleaned internally with a series of sprays.

Radioisotope

This fume hood is made with a coved stainless steel liner and coved integral stainless steel countertop that is reinforced to handle the weight of lead bricks or blocks.

Scrubber

This type of fume hood absorbs the fumes through a chamber filled with plastic shapes, which are doused with a scrubbing medium. The chemicals are washed into a sump, which is often filled with a neutralizing liquid. The fumes are then dispersed, or disposed of, in the conventional manner.

Waterwash

These fume hoods have an internal wash system that cleans the interior of the unit, to prevent a build-up of dangerous chemicals.

 
Detailed Photos
 


FAQ


How a Fume Hood Works

A fume hood is a ventilated enclosure in which gases, vapors and fumes are captured and removed from the work area. An exhaust fan situated on the top of the laboratory building pulls air and airborne contaminants through connected ductwork and exhausts them to the atmosphere.

Depending on its design, the sash may move vertically, horizontally or a combination of the two and provides some protection to the hood user by acting as a barrier between the worker and the experiment.

The slots and baffles within the hood direct the air and, in many hoods, can be adjusted to allow the most even flow. It is important to prevent the baffles from becoming blocked, by excessive material storage or equipment, since this significantly affects the exhaust path within the hood and as a result, the efficiency of hood capture. 

The beveled frame around the hood face, called the airfoil, allows for even air flow into the hood by eliminating sharp curves to reduce turbulence.