CE Medical Anesthesia Ventilator Machine Appratus

Min.Order: 1
Product origin: Nanjing, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 3000 ~ 8000

Description

S1100  respiratory  ventilator machine For ICU Treatment





 Application
Used to assist or replace the spontaneous breathing for adult, pediatric and neonatal more than 2kg.





Specifications
Ventilator modesIPPV(VCV)  /  A/C / PCV/ SIMV/ SPONT/ CPAP/ PSV/S IGH/ MAUN
Tidal volume(Vt)0 ~ 2000mL
Frequency (Freq)
Oxygen concentration
1bpm ~ 100 bpm
21%-100%
I/E4:1~1:8
PEEP0cmH2O ~ 40 cmH2O
Pressure Limit20 cmH2O ~ 100 cmH2O
Monitored Parameters
Frequency (Freq)0 /min ~ 100 /min
Tidal volume(Vt)0 mL ~ 2500 mL
MV

Airway pressure
Dynamic lung compliance testing
ETCO2 Concentration
VTH≥18L/min
VTL≥10L/min

0 cmH2O ~ 100 cmH2O
1mL/cmH2O ~ 1000mL/cmH2O
0mmHg ~ 152mmHg (0%-20%)
Oxygen concentration15 % ~ 100 %
 
Oscillographs display
P-T(pressure - time)
F-T(flow - time)
P-V loop (pressure - volume loop)
V-T(volume - time )
ETCO2-T (End-tidal CO2 - time)
Alarms and protectionThe AC power failure alarm
Internal battery backup low voltage alarm
No tidal volume

High Minute Volume alarm
Low Minute Volume alarm
High Airway pressure alarm
Low Airway pressure alarm
High oxygen concentration alarm
Low oxygen concentration alarm
Continuous pressure alarm
 Suffocation warning
Fan error
Oxygen deficit
The maximum limited pressure <12.5 kPa
Gas sourceO2, AIR
Pressure280kPa-600kPa
Voltage~220V±22V
Power frequency50Hz ± 1Hz
Input power900VA (with air compressor)
250VA (without air compressor)



Features
Air compressor runs stably with low noise, creates quiet environment for doctors and patients.
. Integration breathing circuit design.
Multiple working modes such as volume control and pressure limit.
 . Multiple parameters monitoring interface to show clear parameter to the operator, allow operator   know the patient conditions in all aspects.
Real time pressure-time, flow-time loop graphics, pressure volume loop graphics and high precision ETCO2, O2 concentration detection function included.
Electrical PEEP control
Breathing valve is disassembly and can be disinfected.


Safety
  1. Three levels alarm system, visual and sound alarm information.
  2. With multiple type of alarms, reminding and protection functions.
  3. Self-check before running, eliminate system mulfuction.
  4. Advanced power management control technology.
  5. With built-in backup power supply, when normal power supply shut down, back-up power supply will start work automatically.
  6. Separate design of electric and gas, keep safety running of ventilator.
 

Company Introduction

Nanjing Superstar Medical Equipment Co.,Ltd, belongs to Perlong Medical,  which established in 1993.

Superstar Medical has exclusively focused on ICU devices. Our business line: Anesthesia System, Ventilator, Nitrous Oxide Sedation system, CPAP system, Sleep Therapy System etc.




 
 Product profolio


 

FAQ

Q:Is your quanlity guaranteed ?
Yes, definitely . Our products have been sold to more than 200 countries, we know the quality importance. 

Q: certificates ?
ISO9001,ISO13485, Free Sale certificate, CE certificate

Q:How can I pay for the equipment?
You can pay Dollar,Euro,RMB by T/T,West Union or L/C to our bank as you want.


Q:How to install the machines?
All the ICU products are easy to install with our installation video . Every model have the video ,we will send to clients before install it .

Q:Do you have engineer  come to our location for installation ? 
Yes.







  

  



 