Current Voltage Transformer Vt CT PT Volt Ampere Excitation Curve Characteristic Tester Polarity Turns Ratio Tester for Instrument Transformer Testing

Min.Order: 1
Product origin: Baoding, Hebei, China
Infringement complaint: complaintComplaint
US$ 5000 ~ 8000

Description

 

Product Description

The need for a comprehensive current transformer testing regime is evident when the alternative is considered: a catastrophically damaging current transformer fault. A fault leading to an open secondary could cause the primary current to overwhelm the insulation, causing the winding to short circuit. WESHINE's range of current transformer test equipment allows you to construct an in depth test and maintenance programme to prevent problems before they occur.

A routine series of diagnostics and testing for your current transformer should include CT saturation testing to identify the knee point against IEEE or IEC standards, CT ratio tests to identify that the voltage ratio is within expected parameters and current transformer resistance testing for both the transformer windings and CT insulation resistance testing.

Saturation testing for a current transformer identifies the rated knee point against IEEE or IEC standards, the point at which the transformer is no longer able to output current in proportion to its specified ratio.

Ratio tests under normal load are achieved by comparing voltage applied to the secondary winding against the resulting voltage produced on the primary winding. Current transformer resistance tests inject test voltage to measure the DC current and calculate the resistance with allowance for temperature. 


FEATURES:
* Variable frequency 
* 0 ~ 220 Vrms, 5 Arms, peak: 20 A 
* Current output up to 150A 
* Performs Secondary Burden tests
Upgraded on the basis of
VS-2800
* Variable frequency effective avoid the iron core resonance causes overvoltage.
* Less than 16 lb (8Kg), smallest and lightest unit on the market.
* Especially suitable for the test of Transient Current Transformer.

 
 
PRODUCT INFORMATION
Product Name
PT and CT Analyzer (variable frequency)
Output
0 ~ 220 Vrmas, 5 Arms
Output Current
0 ~ 150 A
CT grouped testing
* Demagnetization, Knee Points, Ratios, Saturation Curves, Winding Resistances, Polarities and Phase Deviation...
VT testing
* Demagnetization, Ratios, Winding Resistance, Polarity and Phase Deviation...
Weight
≤ 8 kg
Certificates
CE; EMC; LVD; ISO; IEC;
Dimensions
380mm*180mm*240mm
Model Number
VS-2800A

Recommend Products

 

Feedback

Company Profile


Product Tag: