Items | Test Method | Unit | Standard for Knitted DWF | Standard for Woven DWF | Standard for TPU DWF | |||||||||
Material Type | / | / | General | Reinforced | General | Reinforced | Knitted & General | Woven & General | ||||||
DWF-G | DWF-R | DWF-G,Woven | DWF-R,Woven | DWF-U,Knitted | DWF-U,Woven | |||||||||
Basic Fabric | Knitted | Woven | Knitted | Woven | ||||||||||
Base Fabric | ISO 2076 | / | 100%PES | 100%PES | 100%PES | 100%PES | ||||||||
Yarn Size (warp*weft*Space) | ISO 2060 | Denier | 5000D*500D*500D | 1000D*1500D*500D | 5000D*500D*500D | 1000D*1500D*500D | ||||||||
Weave Style (warp*weft) | ISO 4602 | (inch*inch) | 16*23 | 25*27 | 16*23 | 25*27 | ||||||||
Space Piles Height | ISO 2286-1 | mm | 30~300 | 30~500 | 30~200 | 30~200 | ||||||||
Shape | / | / | Starry/Wavy/linear | Starry/linear | Starry/Wavy/linear | Starry/linear | ||||||||
Total Weight | ISO 2286-2 | g/m2 | 2400-2900 | 3300-3500 | 1800~2300~2600 | 2300~2600 | 2000~2800 | 1800~2400 | ||||||
Breaking Strength Warp | ISO 1421 | N/5cm | 1800 | 3500 | 2700 | 5000 | 1800 | 2500 | ||||||
Breaking Strength Weft | N/5cm | 2400 | 3800 | 4500 | 5500 | 2200 | 4000 | |||||||
Trapezoid Tear Strength Warp | DIN 53363 | N | 600 | 700 | 500 | 800 | 450 | 450 | ||||||
Trapezoid Tear Strength Weft | N | 500 | 700 | 700 | 1000 | 400 | 500 | |||||||
Adhesion Strength | ISO 2411 | N/5cm | 150 | 200 | 150 | 200 | 150 | 150 | ||||||
Temperature Resistance | DIN EN 1876-1 | Degree(ºC) | -30 /+70 | -30 /+70 | -30 /+70 | -30 /+70 | -30 /+70 | -30 /+70 | ||||||
Recommended Pressure | / | PSI | 20 | 20 | 20 | 20 | 18 | 18 | ||||||
Max. Pressure | / | PSI | 30 | 30 | 30 | 30 | 25 | 25 |