Anesthesia Machine System with Sevoflurane Vaporizer

Min.Order: 1
Product origin: Nanjing, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 4000

Description


Middle-End Anesthesia System Factory Wholesale With CE and ISO13485 Certification 

Technical Specification
Ventilation Model
 IPPV, A/C, PCV, PSV, SIMV, SIGH, MANUAL
Ventilator parameter range
Flowmeter
O2 (0.1~10 L/min)
N2O (0.1~10 L/min)
AIR (0.1~10 L/min)
Rapid oxygen supply
25 L/min~75 L/min
Tidal volume(Vt)
0, 20 mL~1500 mL
Frequence
1 /min~100 /min
I:E
4:1~1:8
PEEP
0 cmH2O~30 cmH2O
Pressure triggering sensitivity (Ptr)
-20 cmH2O~0 cmH2O (Based on PEEP)
Flow trigger sensitivity (Ftr)
0.5 L/min~30 L/min
Pressure control (PC)
5 cmH2O~60 cmH2O
SIGH
0 (off) 1/100~5/100
Apnea ventilation
OFF,5s~60s
Pressure limit
20 cmH2O~100 cmH2O
Monitoring parameter
Frequence(Freq)
0 /min~100 /min
Tidal volume(Vt)
0 mL~2000 m
MV
0 L/min~100 L/min
Oxygen concentration
15 %~100 %
Oscillogram
P-T (pressure - time)
F-T (flow - time)
Alarm and protection
The AC power failure alarm
Power failure or no connection
Low voltage alarm for back up battery 
<11.3±0.3V
No tidal volume
≤5mL within 6s
High oxygen concentration alarm
19%~100%
Low oxygen concentration alarm
18%~99%
High airway pressure alarm
20 cmH2O~100 cmH2O
Low airway pressure alarm
0 cmH2O~20 cmH2O
High minute volume alarm
Adult (5 L/min~20 L/min)
Paed (1 L/min~15 L/min)
Low minute volume alarm
0~10 L/min
Continuous pressure alarm
(PEEP+1.5 kPa) over 16s
Suffocation warning
5s~60s no spontaneous ventilation
The maximum limited pressure
<12.5 kPa
Fan error
Show on screen
Oxygen deficit
Show on screen
Working Condition
Gas source
O2, N2O, AIR
Pressure
280 kPa~600 kPa
Voltage
100~240V
Power frequency
50/60 Hz
Packing
Wooden case packing size
L 920* W 970* H 1380mm
G.W.
156KG
N.W
102KG
CBM
1.23m³
Product pictures
Application
 The Anesthesia machine makes a good performance in Intensive Care Units (ICU), Operation room, Anesthesiology Department and other departments.
 Professional design for adult, child and infant inhalation anesthesia and respiratory management with advanced ventilation modes.
 Outstanding ergonomic design, it ranks high level in safty, stability and convenience as well as user experiences.
 S6100 comfortable classic model, easy to use and be designed together with experienced experts to streamline your anesthesia workflow.
Trust point
 Simplicity: 4 static casters with self-locking function.
 Precision in an anesthesia ventilator with multiple ventilation modes: IPPV, A/C, PCV, SIMV, SIGH and MANUAL.
 Flexible configurations able to customize your requirements.
 International standard and advanced technology suitable for wide range use.
 Compact interface and big screen give you better operating experience.
 Over 5,000 units are installed in more than 200 countries.
 Designed and manufactured by Superstar Medical with over 25 years of experience in ICU field.
Feature
 10.4" TFT LCD screen displays the Ventilation parameters, Alarm information and Oscillogram.
 High precision flowmeter, instantly know the fresh gas flow to your patient.
 Integrated breathing circuit design, ensure easy operating and keep tidy.
 Multiple working modes such as volume control and pressure limit, adapt to wide range patient
 Vaporizer with temperature, pressure, flow compensation and self-lock function, keep safety anytime.
 Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects
 Pressure-time, low-time loop oscillogram and high precision ETCO2, O2 concentration show in real time.
 Vital sign monitor and anesthetic gas monitor are optional.
 ETCO2 module and Anesthesia Gas Scavenging System (AGSS) are optional.
Safety
 3 level alarm system, visual and sound alarm information
 With multiple type of alarm, reminder and protection functions.
 Advanced power management control technology
 Built-in backup battery provide the emergency power supply to the unit.
 Low O2 pressure alarm and N2O cut-off protection.
Company Profile
Nanjing Superstar Medical Equipment Co., Ltd was established in 2008, is located in Nanjing Luhe Economic Development Zone, Jiangsu Province, covering an area of nearly 14 acres and a building area of nearly 68,000 square meters. The company has more than 650 employees and is a national high-tech enterprise, Nanjing gazelle enterprise integrated with R&D, production and sales.The company's products cover Anesthesia System, Respiratory Machine, Sleeping Therapy System, Nitrous Oxide Sedation System and Agent Products, covering household, medical, animal three fields. All products have been awarded CE certificates, IS09001 and IS013485, and with market throughout more than 200 countries and regions worldwide. The company always adheres to independent R&D, scientific and technological innovation, continues to provide customers at home and abroad with products of high performance and high quality, to provide safer, more stable, more convenient services for patients around the world.
Exhibition
Delivery and Shipping
Product Tag:
Related categories:
Scroll to Top