Petrol station measuring meter fuel tank inventory management system
What are fuel tank inventory management system used for?
Petrol station fuel tank inventory system are used for monitoring fuel liquid level, volume and temperature inside fuel storage tanks. It is widely used at petrol station and skid-mounted fueling site. It also can be used at chemical factory, pharmacy industry and waste water tanks.
The fuel tank inventory management system smart console is a powerful product developed and produced by Windbell. Together with SP300 series magnetostrictive liquid level meter constitute the complete fuel tank inventory management system.
The smart console is the display terminal of the fuel tank inventory management system and can detect 1 to 12 tanks at the same time. It can monitor product level, water level, temperature, product volume, water volume, empty volume, all kinds of alarms, inventory and delivery information in real time.
International graphic touch screen and user-friendly icon, makes it is easy for new user.
Power | AC220V ±10%, 50/60Hz |
Working temperature | -20 to 60ºC (-4 to 140F) |
Display | 8-inch LCD touch screen, 800x600 resolution |
Ex-proof grade | [EX ia Ga] IIA |
Monitor probes | Standard is 6,Up to 12, |
Leak sensor | Support, 40 Max |
Relay output | 2 groups. Node capacity AC250V/3A. DC30V/3A |
SMS module | Optional |
GPRS module | Optional |
Running/Alarm indicator | Yes |
WIFI function | No |
Inventory and delivery management | Yes |
Density and mass measurement | Yes |
Output voltage | DC 12V |
Safety barrier | WB-GSB03 |
Built-in printer | Optional |
External printer | Support |
RS485 port | 1 |
RS232 port | 2 |
USB port | 1 |
Ethernet port | 1 |
Buzzer alarm | Yes |
External sound-light alarm | Support, optional |
Tank table | Yes, simulate/input/upload |
Reports | Inventory, delivery, shift, alarm, leak detection test, system log, SMS for optional |
PC remote software | PCR200 |
Anti-theft function | Yes |
Dimension (L*W*H) | 30×23×14.5 cm |
Power supply | DC12V |
Precision | ±0.5mm |
Repeatability | ±0.1mm |
Resolution of product level | 0.0069mm |
Resolution of temperature | 0.0078ºC |
Resolution of water level | 0.0069mm |
Temperature range | -40 to 85ºC(-40 to 185ºF) |
Points of temperature measured | 5 |
Maximum communication distance | 1200m |
Communication | RS485 |
Intrinsic safety parameter | Power port: Ui = 15V DC, Ii= 400mA, Pi = 1.5W, Ci = 3.63μF, Li = 0mH; Signal port: Ui = 7.14V DC, Ii= 147mA, Pi = 260mW, Ci = 32.6μF, Li = 0mH; |
Associated apparatus | WB-GSB03 safety barrier |
Explosion proof grade | Ex ia IIA T4 Ga, II 1G Ex ia IIA T4 Ga |
Protection grade | IP68 |
Applicable medium | Gasoline, kerosene, diesel, Ethanol gasoline, Methanol gasoline, Approved light oil |
Definition of wires | Blue - Power +: Brown - RS485A : White - RS485B: Black - Power - |
Communication address | 6 digits, see the"Manufacturing code"or S/N code on probe nameplate, this is also Probe ID in communication with console and FMS |