ZW type non-clogging self-suction sewage pump, not only can be used for general water self-suction pump as without installing the bottom valve, without irrigation water, but also can be pumped containing large pull solid diameter of 60% of the outlet diameter and fiber length of impeller diameter 1.5 times of dirt, sediment, waste mine impurities, class treatment and all engineering sewage and gel liquid, will not reduce the intensity of labor, And easy to install and use, few maintenance, has a broad application market and development before.
Zhongcheng Pump self-priming sewage pump all use computer design and optimization treatment, the company has a strong technical force, rich production experience and perfect detection means, so as to ensure the stability and reliability of product quality. ZW series self-priming non-clogging sewage pump is mainly composed of pump body, impeller, back cover, mechanical seal, pump shaft, bearing seat, inlet valve, gas-liquid separation pipe, water valve, inlet and discharge nozzle, etc.
ZW self-priming non-clogged sewage pump working principle: the pump body is provided with a liquid storage chamber, and through the upper return hole and the circulation hole below the pump chamber is communicated with, constitute the pump axial return external mixed system. After the pump stops working, the pump cavity has stored a certain volume of liquid, when the pump starts, the liquid storage in the pump under the action of the impeller, entrainment with empty and is discharged upward. The liquid returns to the working chamber through the mesh of the liquid separation pipe, and the gas is discharged out of the pump, so that a certain vacuum degree is formed in the pump, and the role of self-priming is achieved.
Self-priming sewage pump in chemical, petroleum, pharmaceutical, mining, paper, fiber, slurry, textile, food, power plant and municipal sewage engineering, public facilities sewage, river aquaculture and other industries.
Model | Flow m³/h | lift m | power kw | rotate speed r/min | efficiency % | NPSH m | Self - Priming Lift m | self-priming time min/m | Weight kg |
ZWL25-8-15 | 8 | 15 | 1.5 | 2900 | 45 | 2.0 | 5.0 | 3 | 68 |
ZWL32-9-30 | 9 | 30 | 3 | 2900 | 48 | 2.5 | 5.0 | 3 | 68 |
ZWL40-10-20 | 10 | 20 | 2.2 | 2900 | 45 | 2.5 | 5.0 | 3 | 95 |
ZWL40-20-15 | 20 | 15 | 2.2 | 2900 | 45 | 2.5 | 5.0 | 3 | 68 |
ZWL40-15-30 | 15 | 30 | 3 | 2900 | 48 | 2.5 | 5.0 | 3 | 68 |
ZWL50-10-20 | 10 | 20 | 2.2 | 2900 | 45 | 2.5 | 5.0 | 3 | 68 |
ZWL50-20-15 | 20 | 15 | 2.2 | 2900 | 45 | 2.5 | 5.0 | 3 | 68 |
ZWL50-15-30 | 15 | 30 | 3 | 2900 | 48 | 2.5 | 5.0 | 3 | 95 |
ZWL50-20-35 | 20 | 35 | 5.5 | 2900 | 48 | 2.5 | 5.5 | 3 | 140 |
ZWL50-20-40 | 20 | 40 | 7.5 | 2900 | 48 | 2.5 | 5.5 | 3 | 150 |
ZWL65-30-18 | 30 | 18 | 4 | 2900 | 45 | 2.5 | 5.0 | 3 | 125 |
ZWL65-25-30 | 25 | 30 | 5.5 | 2900 | 50 | 3.0 | 5.0 | 3 | 135 |
ZWL65-25-40 | 25 | 40 | 7.5 | 2900 | 50 | 3.0 | 5.5 | 2 | 140 |
ZWL65-40-25 | 40 | 25 | 7.5 | 2900 | 50 | 3.0 | 5.0 | 3 | 150 |
ZWL65-65-25 | 65 | 25 | 11 | 2900 | 52 | 3.0 | 5.0 | 3 | 200 |
ZWL80-40-16 | 40 | 16 | 4 | 2900 | 50 | 3.0 | 5.0 | 3 | 125 |
ZWL80-40-25 | 40 | 25 | 7.5 | 2900 | 50 | 3.0 | 5.0 | 3 | 140 |
ZWL80-25-40 | 25 | 40 | 7.5 | 2900 | 50 | 3.0 | 5.5 | 2 | 150 |
ZWL80-65-25 | 65 | 25 | 11 | 2900 | 52 | 3.0 | 5.0 | 3 | 220 |
ZWL80-80-35 | 80 | 35 | 15 | 2900 | 45 | 3.0 | 5.5 | 3 | 250 |
ZWL80-50-60 | 50 | 60 | 22 | 2900 | 55 | 3.0 | 5.5 | 3 | 300 |
ZWL100-100-15 | 100 | 15 | 7.5 | 1450 | 50 | 4.0 | 5.0 | 3 | 230 |
ZWL100-80-20 | 80 | 20 | 7.5 | 1450 | 53 | 4.0 | 5.0 | 3 | 230 |
ZWL100-100-20 | 100 | 20 | 11 | 1450 | 53 | 4.0 | 5.0 | 3 | 270 |
ZWL100-100-30 | 100 | 30 | 22 | 1450 | 53 | 4.0 | 5.0 | 2 | 320 |
ZWL100-80-45 | 80 | 45 | 30 | 2900 | 53 | 4.0 | 5.5 | 2 | 380 |
ZWL100-80-60 | 80 | 60 | 37 | 2900 | 53 | 4.0 | 5.5 | 2 | 430 |
ZWL100-80-80 | 80 | 80 | 45 | 2900 | 53 | 4.0 | 5.5 | 2 | 480 |
ZWL125-120-20 | 120 | 20 | 15 | 1450 | 55 | 4.5 | 5.0 | 2 | 380 |
ZWL150-200-15 | 200 | 15 | 15 | 1450 | 60 | 5.0 | 5.0 | 3.5 | 380 |
ZWL150-200-20 | 200 | 20 | 22 | 1450 | 60 | 5.0 | 5.0 | 3 | 420 |
ZWL150-200-25 | 200 | 25 | 30 | 1450 | 60 | 5.0 | 5.0 | 3 | 520 |
ZWL150-180-30 | 180 | 30 | 37 | 1450 | 65 | 5.0 | 5.0 | 3 | 580 |
ZWL150-180-38 | 180 | 38 | 55 | 1450 | 45 | 5.0 | 5.0 | 3.5 | 700 |
ZWL200-280-14 | 280 | 14 | 22 | 1450 | 65 | 5.0 | 5.0 | 3 | 600 |
ZWL200-300-18 | 300 | 18 | 37 | 1450 | 65 | 5.0 | 5.0 | 3 | 680 |
ZWL200-280-28 | 280 | 28 | 55 | 1450 | 55 | 4.8 | 5.2 | 3 | 820 |
ZWL250-420-20 | 420 | 20 | 55 | 1450 | 61 | 6.0 | 4.5 | 2.5 | 1020 |
ZWL300-800-14 | 800 | 14 | 55 | 1450 | 65 | 6.0 | 4.5 | 2.5 | 1200 |
ZWL direct connected self-priming sewage pump adopts direct connected structure compared with similar domestic products, with simple and compact structure, less vibration, good self-priming performance, strong sewage capacity, high efficiency and energy saving, easy to use and maintenance, etc., in the sewage pump series of products belongs to various technical performance indicators excellent, has a broad application market and development prospects.
Preparation and trial operation of self priming pump before starting
1. Check whether the fasteners of pump base, pump cover and other connecting parts are loose. If it is loose, it should be tightened.
2. Is the wind blade of the motor stuck or abnormal sound by hand?
3, open the pump above the water valve, add liquid storage water is not less than two-thirds of the pump volume, close the valve. After the boot does not need to pour water.
4. Connect to the power supply and try to turn it around. From the motor end, it is clockwise turning (it is forbidden to reverse). If there are abnormal phenomena, the cause should be found out and eliminated.