TD1540 DC Shunt Calibration Device

Min.Order: 1
Product origin: Changsha, Hunan, China
Infringement complaint: complaintComplaint
US$ 23800 ~ 26500

Description
TD1540 DC Shunt Calibration Device

1. Summary
TD1540 is a set of instrument specially used for calibrating DC shunt, which is composed of DC standard large current source and precision DC voltmeter. It can be applied to the verification of DC shunt used for various measurements by metering and power departments at all levels, and also to the quality inspection of products by manufacturers.

2. Features
Accuracy: Class 0.02 / Class 0.05
DC standard current:0.5A~600 A
Precision DC voltage measurement: 100 μV~11 V
Resistance measurement range: 200 nΩ~6 Ω
A variety of quantity output adjustment methods
Measuring the resistance value and basic error of the shunt, drawing R (I) and R (t) curve
Professional test software (option)

3. Applications
 Calibrate High-current DC Meter
  1. The device has a built-in DC current standard source with an output range of 0.5 A~600 A, and the current accuracy of the class 0.02 device reaches class 0.01, which is suitable for calibrating the DC large ammeter of class 0.05 and below.
  2. The device can provide 600 A large current for the primary side of current conversion devices (such as transformer, I/I conversion, I/V conversion, etc.).
 
 Verification of DC Shunt
  1. DC high current standard source: Maximum output is 600 A, which can be used as the primary current input of the DC shunt.
  2. DC small signal voltmeter: Support voltage input range is 100 μV~11 V, which can measure the secondary output voltage of the shunt.
  3. Verification and test of DC shunt (option): Can measure the resistance value and basic error of the diverter, draw R (I) and R (t) curves.
 

4. Functional Features

 High accuracy and stability of current output
Precise integrated circuit devices are used to ensure the long-term accuracy of the system.
Adopt the design principle of closed-loop negative feedback system to ensure the stability of output.
 
 Convenience of Operation
Digital programmable keys: It can realize fixed-point output, rotary encoder, step adjustment and multiple input modes.
 
 Multiple Output Methods
The instrument has a "fixed-point output" mode. The required output value can be directly set by pressing the number keys on the console or clicking the touch screen, and the instrument will automatically switch to the optimal range output;
In particular, when setting the current, input the current value directly.
 
  • Rotary Knob Adjustment Output
The key operation area is equipped with a "rotary knob", which can increase or decrease the value output by rotating clockwise or counterclockwise.
 
 Proportional Output
When calibrating electrical measuring instruments, it is usually necessary to select calibration points according to the proportion of each range of the meter being tested;
The user can select the calibration point of the tested meter through the "percentage verification point" on the touch screen of the instrument.
 
 Professional Test Software (Option)
The device has RS232 communication interfaces, and its software functions can be customized according to customer needs.


5. Specifications

5.1 DC current output DCI

RangeShort-term Stability (% / min)Accuracy
( ± ppm of reading + ppm of range) [1]
Maximum load (V)
Class 0.05Class 0.02Class 0.05Class 0.02
5 A0.0050.003120 + 8060 + 403.5
10 A0.0050.003120 + 8060 + 403.5
20 A0.0050.003120 + 8060 + 403.5
50 A0.0050.003120 + 8060 + 403.5
100 A0.0050.003120 + 8060 + 403.5
200 A0.0050.003120 + 8060 + 403.5
500 A0.0050.003120 + 8060 + 403.5
Note [1] : (ppm = parts per million) (e.g., 10ppm = 0.001%).
  1. Output range:0.5A~600 A, Ripple coefficient: < 0.5 %
  2. 7-digits display, Regulating fineness: 0.001%*RG
  3. Protection function: Open circuit protection, Overload protection

5.2 DC small signal voltage measurement DCV

RangeAccuracy
( ± ppm of reading + ppm of range)
Temperature coefficient @ (15~30) °C
(ppm*RG/°C)
Class 0.05Class 0.02Class 0.05Class 0.02
1 mV150 + 180 + 0.5<30<15
10 mV150 + 380 + 1.5<10<5
100 mV150 + 1080 + 5<10<5
1 V150 + 2080 + 10<5<2
10 V150 + 10080 + 50<5<2
  1. Measuring range: ± (100 μV~11 V), Manual/automatic range switching, 7-digits display
  2. Input resistance: >1 GΩ, Input protection: 50 Vpk, continuously

5.3 DC resistance measurement

Test CurrentVoltage RangeMeasuring Range of ResistanceAccuracy
@ Full scale voltage value
0.050.02
5 A(0.1~1) mV20 μΩ ≤ R ≤ 200 μΩ0.135%0.068%
(1~10) mV200 μΩ < R ≤ 2 mΩ0.065%0.033%
(10~100) mV2 mΩ < R ≤ 20 mΩ0.045%0.023%
(0.1~1) V20 mΩ < R ≤ 200 mΩ0.037%0.019%
(1~3) V200 mΩ < R ≤600 mΩ0.036%0.019%
10 A(0.1~1) mV10 μΩ ≤ R ≤ 100 μΩ0.135%0.068%
(1~10) mV100 μΩ < R ≤ 1 mΩ0.065%0.033%
(10~100) mV1 mΩ < R ≤ 10 mΩ0.045%0.023%
(0.1~1) V10 mΩ < R ≤ 100 mΩ0.037%0.019%
(1~3) V100 mΩ < R ≤300 mΩ0.036%0.019%
20 A(0.1~1) mV5 μΩ ≤ R ≤ 50 μΩ0.135%0.068%
(1~10) mV50 μΩ < R ≤ 500 μΩ0.065%0.033%
(10~100) mV500 μΩ < R ≤ 5 mΩ0.045%0.023%
(0.1~1) V5 mΩ < R ≤ 50 mΩ0.037%0.019%
(1~3) V50 mΩ < R ≤ 150 mΩ0.036%0.019%
50 A(0.1~1) mV2 μΩ ≤ R ≤ 20 μΩ0.135%0.068%
(1~10) mV20 μΩ < R ≤ 200 μΩ0.065%0.033%
(10~100) mV200 μΩ < R ≤ 2 mΩ0.045%0.023%
(0.1~1) V2 mΩ < R ≤ 20 mΩ0.037%0.019%
(1~3) V20 mΩ < R ≤ 60 mΩ0.036%0.019%
100 A(0.1~1) mV1 μΩ ≤ R ≤ 10 μΩ0.135%0.068%
(1~10) mV10 μΩ < R ≤ 100 μΩ0.065%0.033%
(10~100) mV100 μΩ < R ≤ 1 mΩ0.045%0.023%
(0.1~1) V1 mΩ < R ≤ 10 mΩ0.037%0.019%
(1~3) V10 mΩ < R ≤ 30 mΩ0.036%0.019%
200 A(0.1~1) mV500 nΩ ≤ R ≤ 5 μΩ0.135%0.068%
(1~10) mV5 μΩ < R ≤ 50 μΩ0.065%0.033%
(10~100) mV50 μΩ < R ≤ 500 μΩ0.045%0.023%
(0.1~1) V500 μΩ < R ≤ 5 mΩ0.037%0.019%
(1~3) V5 mΩ< R ≤ 15 mΩ0.036%0.019%
500 A(0.1~1) mV200 nΩ ≤ R ≤ 2 μΩ0.135%0.068%
(1~10) mV2 μΩ < R ≤ 20 μΩ0.065%0.033%
(10~100) mV20 μΩ < R ≤ 200 μΩ0.045%0.023%
(0.1~1) V200 μΩ < R ≤ 2 mΩ0.037%0.019%
(1~3) V2 mΩ< R ≤ 6 mΩ0.036%0.019%
  1. Resistance measurement range: 200 nΩ~6 Ω, 6-digits display, Minimum resolution: 1 pΩ
  2. The current test point can be set through the number keys, and the voltage range: manual/automatic switching
  3. After loading the test current, the R (t) change curve can be tested

6. General Specifications
Power supplyAC ( 220 ± 22 ) V,( 50 ± 2 ) Hz;
Warm up time2h;
Maximum power consumption4.8 kVA
Sampling rate0.5 sps
Temperature performanceOperating temperature: 15 °C~30 °C;
Storage temperature: -20 °C ~ 70 °C;
Humidity performanceOperating humidity: ( 20 % ~ 50% ) R·H, No condensation;
Storage humidity: ( 15 % ~ 80% ) R·H, No condensation;
Altitude< 3000 m
WeightAbout 49.5 kg
Communication interfaceRS 232
Unit size623 mm (W) × 548 mm (D) × 260 mm (H) (Excluding handle and support foot)
 