Description

1. Product overview
TD1500 is a wide range, high precision, multi-functional DC standard source precision instrument. It can directly output DC voltage, current, power and electric energy with high stability and high accuracy. The best measurement uncertainty has three specifications of Class 0.01 / Class 0.02 / Class  0.05, which  is  suitable for verification  or  calibration  of various  types  of  DC  measuring instruments. The technical performance of the equipment is in the leading Class among similar products, and it is widely used in electric power, measurement, manufacturing, scientific research and other fields to establish DC measurement standards.

2. Product characteristics
Standard source: 1 mV ~ 1100 V (1150 V @ electric energy selection)
Standard source: 1 μ A ~33 A / 100 A (optional)
Standard source of DC voltage: 100 μ V~4.4 V (optional)
Measurement function of DC voltage: 10 μ V ~ 4.4 V (optional)
A variety of quantity and value output mode
Special automatic test software (optional)
Support for remote control adjustment output (optional)
Verification of DC electricity meter (functional option)
Secondary signal measurement of the transmitter (functional option)
 
3.Technical specifications
3.1 DC Voltage Output DCV
RangeShort-Term Stability
(%/Min)
Optimum Measurement Uncertainty
(k=2)
(Ppm*Rd+Ppm *Rg)


Maximum
Load
Current (mA)
Class
0.05
Class
0.02
Class
0.01

Class 0.05

Class 0.02

Class 0.01
10 mV0.010.0050.003200 + 5 μV100 + 5 μV100 + 5 μV100
30 mV0.010.0050.003200 + 5 μV100 + 5 μV100 + 5 μV100
100 mV0.010.0050.003200 + 5 μV100 + 5 μV100 + 5 μV100
300 mV0.010.0050.003200 + 5 μV100 + 5 μV100 + 5 μV100
1 V0.0050.0050.002200 + 100100 + 5060 + 40500
3 V0.0050.0050.002200 + 100100 + 5060 + 40500
10 V0.0050.0050.002200 + 100100 + 5060 + 40500
30 V0.0050.0050.002300 + 200120 + 8060 + 40800
100 V0.0050.0050.002300 + 200120 + 8060 + 40300
300 V0.0050.0050.002300 + 200120 + 8060 + 40100
600 V0.0050.0050.002300 + 200120 + 8060 + 4050
1000 V0.0050.0050.002300 + 200120 + 8060 + 4030
Note : RD is the read value and RG is the range value
3.2 DC current output DCI


Range
Short-Term Stability
(%/Min)
Optimum Measurement Uncertainty (k=2) (Ppm*Rd+Ppm *Rg)Maximum
Load
Voltage (V)
Class 0.05Class 0.02Class 0.01Class 0.05Class 0.02Class 0.01
10 μA0.010.010.01300 + 200300 + 200300 + 2001 1
30 μA0.010.0050.005300 + 200120 + 80120 + 801 1
100 μA0.010.0050.005300 + 200120 + 80120 + 801 1
300 μA0.010.0050.005300 + 200120 + 80120 + 801 1
1 mA0.010.0050.003300 + 200120 + 80100 + 501 1
3 mA0.010.0050.003300 + 200120 + 80100 + 501 1
10 mA0.010.0050.003300 + 200120 + 80100 + 501 1
30 mA0.010.0050.003300 + 200120 + 80100 + 501 1
100 mA0.010.0050.003300 + 200120 + 80100 + 501 1
300 mA0.010.0050.002300 + 200120 + 8060 + 401 1
1 A0.010.0050.002300 + 200120 + 8060 + 401 1
3 A0.010.0050.002300 + 200120 + 8060 + 404
10 A0.010.0050.002300 + 200120 + 8060 + 404
30 A0.010.0050.002300 + 200120 + 8060 + 403
100 A0.010.0050.002300 + 200120 + 8060 + 403
 
3.3 DC Power / Energy Specification (power optional)



Dc Power /
Power

Output Range
A combination of a DC voltage and a DC current (or a
small DC signal voltage)

Uncertainty Of Measurement
Voltage measurement uncertainty + uncertainty of current measurement (or uncertainty of small DC signal voltage
measurement)













Electric Energy Pulse

Standard Electrical Energy Pulse Input
The  high-frequency full  range value corresponds to 60 kHz;
The low-frequency full range value corresponds to 6 Hz;
Pulse Output
Frequency

The output frequency jitter time was < 10 μ s
Annual Stability Of The Clock
Frequency


Better than ± 50 ppm
Standard Electrical Energy Pulse InputSignal amplitude is 5V, with a TTL Class;
capable ≤ 200 kHz;
FH = 60 kHz power value / voltage range value / current range value
FL = 60 kHz power value / voltage range value / current
range value / 10000
Electric Energy
Error Display

Automatically displayed with a resolution of 0.0001%

3.4 DC small signal voltage output (optional)


Range

Short-term Stability
(%/min)
Measurement
Uncertainty (k=2)
(ppm*RD+ppm *RGV )
Maximum Load
Current
(mA)
1 mV1 μV120 + 2 μV≤ 10
3 mV1 μV120 + 2 μV≤ 10
10 mV1 μV120 + 2 μV≤ 10
 
30 mV1 μV120 + 2 μV≤ 10
100 mV0.005120 + 80≤ 10
300 mV0.005120 + 80≤ 10
1 V0.005120 + 80≤ 10
4 V0.005120 + 80≤ 10
 
 
3.5 Small DC signal measurement (optional)
Voltage / Current rangeMeasuring RangeOptimum Measurement
Uncertainty (k=2)
(ppm*RD+ppm *RG)
1 V±(0~ 1.2) V60 + 40
10 V±(0~ 12) V60 + 40
2 mA±(0~2.4) mA60 + 40
20 mA±(0~24) mA60 + 40
Note : RD is the reading value and RG is the range value

4. General technical specifications
Power SupplyAC (220±22) V  ,(50±2) Hz
Preheating time30 Minutes
Max. Power
dissipation

700 VA

Temperature Performance
Operating temperature: 0°C~40°C;
Calibration temperature: 18°C~28°C;
Storage temperature: -20°C~70°C
Humidity
Performance
Working Humidity: <80% @ 30°C, <70% @ 40°C, and <40% @ 50°C
Storage humidity: (20%~80%) R · H, no condensation
Altitude< 3000 m
WeightAbout 17.5kg
Connect modeThe RS232 interface