Natural Gas Generator 5MW 10MW 20MW power plant

Jichai Brand Generator is designed and manufactured to be high quality, long usage life, easy operation, low maintenance cost, high intelligence with low engine speed, low fuel consumption, low gas quality requirement, tough environmental adaptability, high stability and low fluctuation. The generator is desirable for industrial power solution.

Natural Gas Generator 5MW 10MW 20MW power plant

MAIN SPECIFICATIONS OF GAS GENERATOR SET
Model1100GF-TGas Engine Model16V190ZDT-2
Rated power1000kW/1250KVAAlternatorSiemens Series
Rated voltage400 VStarting method24V DC electric start
Rated speed1000rpmVoltage regulationAutomatic
Rated frequency50HzCooling ModeClose type water cool
Rated current1260AHeat Consumption£ 9500kJ/kWh
Power factor0.8 LaggingDimension (mm)5630x2540x2719mm
Control modeElectric controlNet Weight (kg)15000

Natural Gas Generator 5MW 10MW 20MW power plant

MAIN ELECTRICAL PERFORMANCE OF THE GAS GENERATOR
Voltage
Stabilized regulationInstantaneous regulationRecovery timeFluctuation
±2.5%+20%2 S1%
Frequency
Stabilized regulationInstantaneous regulationRecovery timeFluctuation
0-5% adjustable+10%,-12%< 10 S1%

Natural Gas Generator 5MW 10MW 20MW power plant

MAIN SPECIFICATIONS OF GAS ENGINE
Model16V190ZDT-2
Rated power1000Kw/1250KVA
Number and layout of cylinders:16-cylinders, V-type, 60° included angle
TypeFour strokes, Closed type water cooled, Turbo-charged, Electronic ignition, Electronic speed governor
Ignition typeSpark plug ignition
Intake gas pressure required7-9kPa
Bore´Stroke190´210 mm
Speed Governor(Woodward)  Electric governor
Oil consumption£ 0.3g/kWh
Total lubricating oil capacity (Liters)200L
Exhaust temperature (before turbine)£ 680 °C
Heavy overhauling period56,000h

Natural Gas Generator 5MW 10MW 20MW power plant

Natural Gas Generator 5MW 10MW 20MW power plant

MAIN SPECIFICATIONS OF ALTERNATOR
 
Alternator modelExciting modelInsulation classConnectionCoolingStructure type
1FC (SIEMENS)BrushlessClass F3-phase, 4-wireAir cooledAVR and reactive droop regulator assembled in alternator
 
(Kindly Noted: data shown in above table tested under standard working condition: 25 Dec C, atmospheric pressure 100kPa, relative humidity 30%, altitude <1000m.)

Natural Gas Generator 5MW 10MW 20MW power plant

CONTROL PANEL
Control panel is panel type, vertical structure, model is GPL500. Control panel is equipped with meters showing various parameters of operating status, automatic air switch and timer. All of the electric cells possess three-proof functions.

The Generator possesses the following automatic monitoring and protective functions:

A) Audio or visual alarm for:
-   High oil and water temperature
-   Low oil pressure
-   Over current
-   Short circuit
-   Over-speed
-   Reverse power
B) Shut-off for:
-   Low oil pressure
-   Over-speed
-   Short circuit
-   Over-speed
-   Reverse power
C) Trip-off for:
-  Over-current
-  Short circuit
-  Reverse power
The generator can not only supply power directly to load but also can be paralleled running.


Natural Gas Generator 5MW 10MW 20MW power plant

Natural Gas Generator 5MW 10MW 20MW power plant

OPTIONAL DEVICE
Steel Soundproof Container (sound attenuated canopy)
CHP/ Cogeneration/CCHP Trigeneration
ATS and Synchronization Parallelling Panel
Oil and Water Heater

 
Natural Gas Generator 5MW 10MW 20MW power plant