Standalone ABS LED Screen RFID Reader with Keypad Wiegand for Door Access Control System

Min.Order: 1
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 50 ~ 105

Description

 
Product Description

1. Product Introduction

AC-868 standalone reader, which can be used independently. It has a built-in LCD screen, which can display the card number, and can be customized by the enterprise LOGO, integrated password keyboard, support card swiping and key password to open the door ,  can encrypt 13. 56MHz, support EM card and MIFARE card, easy to use, reliable data storage, integrated with management and automatic control, widely used in offices, supermarkets, shopping malls,scenic spots, automatic doors and other fields.
 
2.Packing List
NameSpecificationQuantity
AC-868 1
Manual 1
Wall plug 4
ScrewФ 3mmX25mm4
Waterproof silicone stripФ 2mm1

3.Features
FeaturesDescription
Large capacityCan support 16000 card number storage
LCD liquid crystal displayCan easily display the card number, and corporate LOGO
Support serial number storage cardImprove the efficiency of card number entry
Various ways to open the door Flexible door opening methods, support card swiping, password or card+password
Easy to use Adding and deleting cards can be easily realized without a computer
Wide range of applicationsDoor entry control, gate access, barrier gate control, access management applications
Card reading type EM card/Mifare card(can be setting)
Encryption frequency13.56MHz

4.Size

5. Card Operation
Note: The initial password is: *123456#, in the settings, * is the return key, # is the confirmation key

1. Enter Card
ID code entryPass * Password # 1 1 User address # Enter the first 5 digits of the ID code #Enter the last 5 digits of the ID code #
Card induction entry
(continuous card number)
Pass * Password # 1 2 Input start addr # Set the number of sheets# 1 #Credit card #
 
Card induction entry
(discontinuous card number)
Pass * Password # 1 2 Input start addr # Set the number of sheets #0 #Credit card Credit card.... #
 

2. Pause Card
 
Address range pause
 
Pass* Password # 1 3 Input start addr # Input end addr #
ID code
suspension
 
Pass * Password # 14 # Enter the first 5 digits of the ID code #Enter the last 5 digits of the ID code #

3. Remove Card
Address range removal
 
Pass * Password # 1 5 Input start addr I # Input end addr #
 
ID code removal
 
Pass * Password # 1 6 Enter the first 5 digits of the ID code # Enter the last 5 digits of the ID code #

4. Recovery Card
Address range restoration
 
Pass * Password # 17 Input start addr # Input end addr #
 
ID code recovery
 
Pass * Password # 1 8 Enter the first 5 digits of the ID code # Enter the last 5 digits of the ID code #
 

5. One-ln-One-Out Control
Enable control
 
Pass * Password # 1 9 Input start addr # Input endaddr # 1 #
 
Disable
control
 
Pass a Password # 1 9 Input start addr # Input end addr#0 #
 

6. User information
Password
 
Pass * Password # 2 1 User address # Input password #
 
Set card
opening
method
 
Invalid
 
Pass * Password # 2 2 Input start addr # Input end addr # 0 #
 
Card
 
Pass * Password # 2 2 Input start addr # Input end addr # 1 #
 
Card or PIN
 
Pass * Password # 2 2 Input start addr # Input end addr # 2 #
 
Card & PIN
 
Pass * Password # 2 2 Input start addr # Input end addr # 3 #
 
Extend
options
 
Disable one-in-one-out control
 
Pass * Password # 2 3 Input start addr # 0 #
 
Enable one-in-one-out control
 
Pass * Password # 2 3 Input start addr# 1 #
 
Note: Patrol card is an item that can be set but has no function
 

7. Card  Machine Parameters(1)
Onoff openzone
 
Disable timed door opening
 
Pass * Password # 3 2 0 # 0 # 0 # 0 #
 
Enable timed door opening
 
Pass * Password # 3 2 1 # 1 # 1 # 1 #
 
Door lock action time setting
 
Pass * Password # 3 3 Enter the action time of the main controller # Enter WG action time #
 
Door opening waiting time setting
 
Pass * Password # 3 4 Enter the number of seconds the host controller waits #Enter the number of seconds to wait for WG #
 
Alarm output action time setting
 
Pass * Password # 3 5 Input alarm output action seconds #
 
Alarm output delay time setting
 
Pass * Password # 3 6 Enter the number of seconds to delay the alarm output #
 
Alarm start delay time setting
 
Pass * Password # 3 7 Enter the number of seconds to delay the start of the guard # Input warning output interval time #
 
Alert password setting
 
Pass * Password # 3 8 Enter alert password
 
User password length setting
 
Pass * Password # 3 9 Enter user password length # Enter the card number byte length # Enter card number display format
(0: NO , 1:WG , 2: ABA , 3: HEX ,4: WG26 , 5: ABA8) #
 

8. Card  Machine Parameters(2)
Automatic door lock setting
 
Disable auto-lock 
 
Pass * Password # 4 1 0 # 0 #
 
Enable auto-lock
 
Pass * Password # 4 1 1 # 1 #
 
Door open button

enable setting
 
Disable door open button
 
Pass * Password # 4 2 0 # 0 #
 
Enable door open

button
 
Pass * Password # 4 2 1 # 1 #
 
Miscellaneous

settings
 
Prohibit any card 

reading card
 
Pass * Password # 4 3 0 # 0 #

Enter whether the Wiegand and the main controller share the door

(0: NO,1: YES) #

Enter the interval time between repeated reading of the same card #
Enter the maximum number of continuous input errors within 30 seconds #
 
Enable any card reader row
 
Pass * Password # 4 3 1 # 1 #

Enter whether the Wiegand and the main controller share the door
(0: NO, 1:YES) #

Enter the interval time between repeated reading of the same card # Enter the maximum number of continuous input errors within 30 seconds #
 
Note: Time attendance, verify password, button to open the door, all can be st but has no function
 
Forced door opening alarm settingDeactivate forced open door to generate alarm
 
Pass  * Password # 4 4 0 # 0 #
 
Enable forced door opening to generate alarm
 
Pass * Password # 4 4 1 # 1 #
 
Close the door to cancel the alarm

setting
 
Deactivate close the door to

disarm the alarm
 
Pass  * Password # 4 5 0 # 0 #
 
Enable door

close to dismiss alarm
 
Pass  * Password # 4 5 1 # 1 # 
 
one in one out control
 
Disable one-in-one-out control
 
Pass  * Password # 4 6 0 #

Enter the control direction of the main controller (0: exit, 1 entry) #
0 # Enter the WG system direction (0: exit, 1: entry) #
 
Enable one-in-one-out control
 
Pass  * Password # 4 6 1 #

Enter the control direction of the main controller (0: exit, 1 entry) #
1 # Enter the WG system direction (0: exit, 1: entry) #
 
restore factory defaultPass * Password # 49 Enter the item to factory reset (0: system parameters, 1: user settings, 2: system & user)
 

9. Toolbox 
language settings
 
Chinese
 
Pass * Password # 5 1 0 #
 
English
 
Pass * Password # 5 1 1 #
 
Administrator

password setting
 
Pass * Password # 5 2 Enter password #
 
Administrator scope settings
 
Pass * Password # 5 3 Enter starting address # Enter end address #
 
Opening

hours setting
 
Pass * Password # 5 6 Input group #

Enter the time (within 24 hours), whether the input host is valid (0: invalid, 1: valid) #
Enter the cycle in sequence (0: invalid, 1: valid) #
 
View system

information
 
Pass * Password # 5 7
 
Clock setting
 
Pass * Password # 5 8

Follow the date(year-month-day), and then enter the time(hour,minute,second)in turn #
Enter date display mode (0:day/month, 1:month/day) #
 
Back to main page
 
Pass * Password # 6
 
Set alert
 
Pass * Password # 7
 

10. Products Parameters
Working power
 
DC 9-20V (with reverse polarity protection) 0.3A@12V
 
Operating temperature
 
-10"C~+65'C
 
Degree of protection
 
IP65
 
Number of cards saved
 
16000
 
Display method
 
Dot matrix LCD screen with backlight
 
Language type
 
Traditional chinese/english
 
Number of keys
 
16 keys (10 numeric keys, *#, 4 function keys)
 
RS485 interface
 
1, available for device updates
 
Ethernet interface
 
Reserved (optional)
 
Wiegand input interface
 
1
Door open output interface
 
1, including COM/NO/NC
 
Alarm output interface
 
1, NO/NC optional
 
Non-isolated input interface
 
4
OC output interface
 
6
LED status indication
 
Power indicator, alarm indicator, error indicator, warning indicator, cardreading indicator, programming mode indicator
 
Size
 
128X87X46mm
 

11. Definition Of Wiring

12. Product Application Scenarios
1. Access Control Application (Anode Lock)

2. Access Control Application (Cathode Lock)

3. Access Control Application (Magnetic Lock)

4. Application Of Connecting Gate (JUTAI BR-110)

5. Wiring Diagram Of the Whole Set Of Access Control Application System

Certificate



Packing/Shipping




More and More Details Info Please Scan JUTAI Offical QR Code:








Product Tag:
Related categories:
Scroll to Top