· 100A Contact switching capability
· One set of normally open contacts
· Coil power consumption is:22~40W Min~Max
· Application Scope:Oil pump startup, Battery truck, Electric forklift,
Electric winch, Electric vehicle, Excavator, Automobile air conditioner
and lawm mowerpower on-off control of DC power supply systems.
· Product features:Small volume, high breaking capacity, sealing protection,
and various installation methods,which can adapt to harsh service environment
· Product certification: CE
Model | W2401-100/O |
Contact form | One set of normally open |
Contact load | 100A |
Insulation resistance | Min. 100MΩ at 500VDC |
Dielectric Strength | 1000VAC 50 HZ/60 HZ (1 minute) Leakage current less than 1mA |
Instantaneous maximum current | 300A ,≤1S |
Pull in time(ms) | ≤30 |
Release time(ms) | ≤50 |
Pull-in voltage (DC V) | ≤75% US |
Release voltage (DC V) | 5~40% US |
Operating ambient temperature | -25ºC~+55ºC |
Mechanical life | ≥300,000 second |
Degree of protection | IP67 |
Working system | Short term working system |
Vibration | (10~200)Hz acceleration ≤3.5g |
To attack | (60) Times / minute acceleration 6g |
Model | Coil voltage (V) | Pull-in voltage(V) | Release voltage(V) | Starting current(A) |
W2401-100/O | 12 | 10~70% | 5~40% | ≤2.5 |
24 | ≤1 | |||
48 | ≤0.6 |
1.When installing the contactor, the tightening torque of the main circuit wiring screw nut is 8~10N.m;
Control circuit wiring screw nut tightening torque 1~1.5N.m.
2.The driving circuit power of the product coil must be greater than or equal to the product coil power,
Otherwise the cutting capacity of the product will be reduced.
3.The voltage continuously applied to the coil shall not exceed the maximum allowable voltage.
Otherwise, the abnormal heating of the coil will shorten the life of the insulation layer.