Electrical data(Ta=25ºC±5ºC,RL=2KΩ,CL=10000PF) |
Type Parameter | TKC100 EKB52 | TKC200 EKB52 | TKC500 EKB52 | TKC800 EKB52 | TKC1000 EKB52 | TKC1500 EKB52 | TKC1800 EKB52 | TKC2000 EKB52 | Unit |
(Ipn) Rated current(Ipn) | ±100 | ±200 | ±500 | ±800 | ±1000 | ±1500 | ±1800 | ±2000 | A |
(Ip) Measuring range(Ip) | ±200 | ±400 | ±1000 | ±1600 | ±2000 | ±3000 | ±3600 | ±4000 | A |
Rated output | @Ip=±Ipn ±1.0±1% | V | |||||||
Zero voltage | @Ip=0 2.5±0.6% | V | |||||||
Supply voltage | +5±5% | V | |||||||
Power Consumption | ≤20 | mA | |||||||
Offset drift | @ -40~+85ºC ≤±0.7 | mV/ºC | |||||||
output drift | @ -40~+85ºC ≤±1 | mV/ºC | |||||||
Linearity | @Ip=0-±Ipn ≤1 | %FS | |||||||
Response time | ≤5 | uS | |||||||
Bandwidth | @DC,(-3dB) 25 | KHz | |||||||
Galvanic isolation | @ 50HZ, AC ,1min 2.5 | KV |