☆ Set up precision current test system |
|
☆ Calibrate AC high current source / meter |
It can be used to calibrate AC high current standard sources/meters with precision voltmeters. |
☆ Build a high-current power/energy measurement system |
(1) TH0600 (Type I/V) can be used with V/V conversion equipment such as TH0150 broadband voltage divider, TH018 0 precision AC and DC high voltage divider, etc.), TH2000 vector voltage analyzer to form a high-current power/energy precision measurement system. (2) It is used to measure the output power of high-power power supply, the efficiency of conversion equipment, calibrate high-current power source, power meter and other equipment. |
☆ Calibrate instrument transformer and I/V converter |
If the selected TH0600 is proportional to the instrument transformer under test, it can be calibrated using the difference method. |
(1)If the TH0600 selected is not proportional to the transformer or I/V converter under test, it can be calibrated using the comparative method . (2)Note: The DUT is a current transformer, and an external standard resistor must be connected for I/V conversion. |
Model | Primary Nominal current (A) | Secondary Nominal current (A) | Load resistance (Oh) | Measurement accuracy (± μA/A, corresponding full-scale value). @50Hz | Phase shift (μrad, corresponding full-scale value). @50Hz |
TH060 0-I-D-01A-01A-5 | 0.1 | 0.1 | 100 | 5 | 80 |
TH060 0-I-D-02A-01A-5 | 0.2 | 0.1 | 50 | 5 | 50 |
TH060 0-I-D-05A-01A-5 | 0.5 | 0.1 | 20 | 5 | 15 |
TH060 0-I-D-1A-01A-5 | 1 | 0.1 | 10 | 5 | 10 |
TH060 0-I-D-2A-01A-5 | 2 | 0.1 | 10 | 5 | 10 |
TH060 0-I-D-5A-01A-5 | 5 | 0.1 | 10 | 5 | 10 |
TH060 0-I-D-10A-01A-5 | 10 | 0.1 | 10 | 5 | 10 |
TH060 0-I-D-20A-01A-5 | 20 | 0.1 | 10 | 5 | 10 |
TH060 0-I-D-50A-01A-5 | 50 | 0.1 | 10 | 5 | 10 |
TH060 0-I-D-100A-01A-5 | 100 | 0.1 | 10 | 5 | 10 |
TH060 0-I-D-200A-1A-5 | 200 | 1 | 10 | 5 | 10 |
Model | Primary Nominal current (A) | Secondary Nominal current (A) | Load resistance (Oh) | Measurement accuracy (± μA/A, corresponding full-scale value). @50Hz | Phase shift (μrad, corresponding full-scale value). @50Hz |
TH0600-I-T-200A-01A-20 | 200 | 0.1 | 10 | 20 | 20 |
TH0600-I-T-500A-01A-10 | 500 | 0.1 | 10 | 10 | 10 |
TH0600-I-T-1kA-1A-10 | 1 k | 1 | 1 | 10 | 10 |
TH0600-I-T-2kA-1A-10 | 2 k | 1 | 1 | 10 | 10 |
Model | Primary Nominal current (A) | Secondary Nominal voltage (V) | Measurement accuracy ( ± 1×10-6, corresponding full-scale values). @50Hz | Phase shift (μrad, corresponding the full-scale value). @50Hz |
TH0600-U-D-01A-1 V-30 | 0.1 | 1 | 30 | 30 |
TH0600-U-D-0 2A-1V-30 | 0.2 | 1 | 30 | 30 |
TH0600-U-D-0 5A-1 V-30 | 0.5 | 1 | 30 | 30 |
TH0600-U-D-1A-1 V-30 | 1 | 1 | 30 | 30 |
TH06 0 0-U-D-2A-1 V-30 | 2 | 1 | 30 | 30 |
TH06 0 0-U-D-5A-1 V-30 | 5 | 1 | 30 | 30 |
TH06 0 0-U-D-10A-1 V-30 | 10 | 1 | 30 | 30 |
TH06 0 0-U-D-20A-1 V-30 | 20 | 1 | 30 | 30 |
TH06 0 0-U-D-50A-1 V-30 | 50 | 1 | 30 | 30 |
TH06 0 0-U-D-100A-1 V-30 | 100 | 1 | 30 | 30 |
TH06 0 0-U-D-200A-1 V-30 | 200 | 1 | 30 | 30 |
Model | Primary Nominal current (A) | Secondary Nominal voltage (V) | Measurement accuracy ( ± 1×10-6, corresponding full-scale values). @50Hz | Phase shift (μrad, corresponding the full-scale value). @50Hz |
TH0600-U-T-200A-1 V-30 | 200 | 1 | 30 | 30 |
TH0600-U-T-500 A-1 V-30 | 500 | 1 | 30 | 30 |
TH0600-U-T-1K A-1 V-30 | 1 k | 1 | 30 | 30 |
TH0600-U-T-2K A-1 V-30 | 2 k | 1 | 30 | 30 |
TH06 0 0-U-T-3k A-1 V-30 | 3 k | 1 | 30 | 30 |
TH06 0 0-U-T-5 k A-1 V-30 | 5 k | 1 | 30 | 30 |
TH06 0 0-U-T-6k A-1 V-30 | 6 k | 1 | 30 | 30 |
TH06 0 0-U-T-10k A-1 V-30 | 10 k | 1 | 30 | 30 |
Power supply | -- |
Warm-up time | -- |
Temperature performance | Working temperature: 18°C~28°C; Storage temperature: -10 °C ~ 55 °C |
Humidity performance | Operating humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C Storage humidity: (20%~80%) R· H, no condensing |
altitude | < 3000 m |