TUNKIA TH2000 High Precision Dual Channel Vector Voltage Analyzer for wideband current voltage power calibration

Min.Order: 1
Product origin: Changsha, Hunan, China
Infringement complaint: complaintComplaint
US$ 28000 ~ 58000

Description
TH2000 Vector Voltage Analyzer
 
Product Description

TH2000 is a high-precision vector voltage analyzer, it can measure the ratio error and phase displacement between two channel voltage. With the function of measuring and analyzing various electrical parameters, such as voltage, current, frequency, phase, harmonic, power, etc., TH2000 is suitable for wideband electrical measurement scenarios.

Features

 

(1) Dual channel voltage measurement range: 0.5 mV ~ 6 V
(2) Frequency measurement range: DC, AC 10 Hz ~ 20 kHz
(3) The best uncertainty of voltage and power are 50ppm and 100ppm
(4) The Best uncertainty of phase displacement is 0.0005°
(5) Supporting dual channel voltage multiplication and division operation
(6) Can measure and analyze the 2nd~256th harmonics
(7) Can display harmonic content, total harmonic distortion and spectrum diagram
(8) Statistical analysis of the measured electrical parameters
(9) Supporting both internal and external synchronization
(10) Supporting battery power supply, to improve CMRR
(11) USB, RS232 and LAN communication interfaces
(12) Equipped with LCD touch screen
 
Application


(1) Measuring wideband voltage
(2) Measuring wideband current
(3) Measuring wideband electrical parameters of dual channel
(4) Building wideband power / electrical energy measurement system
(5) Calibrating wideband power source / meter and power analyzer
(6) Calibrating the ratio error and phase displacement of wideband current transformer / transducer
(7) Calibrating the ratio error and phase displacement of wideband voltage divider / transducer
 

 Measuring Wideband Voltage 
Equipped with wideband voltage divider (such as TH0150) to build a wideband voltage measurement system and calibrate a wideband voltage source / meter.
 
 Measuring Wideband Current
Equipped with coaxial shunt (such as TH0400) to build a wideband current measurement system and calibrate a wideband current source / meter.

 Building Wideband Power / Electrical Energy Measurement System
Equipped with wideband V / V conversion device (such as TH0150) and wideband I / V conversion device (such as TH0400) to build a wideband power / electrical energy measurement system and calibrate a wideband power source / meter and power analyzer.

 Calibrating Wideband Transformer / Transducer
Equipped with wideband current transformer / sensor and coaxial shunt to build a wideband measurement system and calibrate the ratio error and phase displacement of a wideband transformer, transducer or I/V conversion standard.
 
 Calibrating Wideband Voltage Divider/ Transformer 
Equipped with voltage divider to build a wideband measurement system and calibrate the ratio error and phase displacement of a wideband voltage divider, transformer or transducer.
 
Specifications

 

5.1 Wideband voltage measurement

RangeAccuracy
± (ppm of reading + ppm of range) [1]@ ( 23 ± 5 )°C
DC10 ~ 2020 ~ 4040 ~ 1 k1 k ~ 5 k5 k ~ 20 k
2 mV500 + 10300 + 8.0300 + 5.0500 + 3.0600 + 3.0800 + 3.0
5 mV300 + 10200 + 5.0300 + 3.0200 + 2.0250 + 2.0250 + 2.5
10 mV100 + 10250 + 5.0250 + 2.0200 + 1.5250 + 1.5250 + 2.0
20 mV80 + 10200 + 10200 + 2.0200 + 1.5300 + 1.5300 + 2.0
50 mV60 + 10300 + 10200 + 2.0150 + 1.8200 + 1.8250 + 2.0
100 mV50 + 15300 + 15150 + 2.080 + 1.8120 + 1.8150 + 2.0
200 mV50 + 20300 + 20120 + 2.060 + 1.890 + 1.8120 + 2.0
500 mV50 + 30300 + 30100 + 3.050 + 2.560 + 2.5120 + 3.0
1 V45 + 30300 + 30100 + 5.045 + 3.560 + 3.580 + 5.0
2 V45 + 35300 + 30100 + 1045 + 660 + 690 + 10
5 V45 + 50300 + 50100 + 2045 + 1560 + 1580 + 20
Note [1] : (ppm = parts per million) (e.g., 10ppm = 0.001%).
 

5.2 Frequency / Phase Measurement

FrequencyMeasuring range10.000 000 Hz~20.000 000 kHz
Minimum resolution1 μHz
Accuracy0.005%*RD
PhaseMeasuring range000.000 00° ~ 359.999 99°
Minimum resolution0.000 01°
Accuracy± 0.001°@45 Hz~1 kHz
± 0.003°@1 kHz~5 kHz
 

5.3 Ratio Error Measurement

Accuracy45 Hz ~ 1 kHz60 ppm
1 kHz ~ 5 kHz100 ppm
Note0.2 V ~ 6 V, U1 / U2≈1
 

5.4 Energy Pulse

(1) The full-scale value corresponds to 60 kHz when high-frequency pulse is output
(2) The full-scale value corresponds to 6 Hz when low-frequency pulse is output
(3) Energy pulse input: frequency ≤ 10 kHz, voltage: 0 ~ 3.3 V…24 V

6. Ordering Information

 
Note: the specifications of accuracy 20ppm, frequency 100kHz and 1MHz are customized products.

7. General Specifications

Power SupplyAC: 195 V ~ 242 V / 47 Hz ~ 63 Hz
Lithium battery (built-in)
Maximum Power Consumption30 W(under non-charging condition)
Warm-up Time30 minutes, shall not be less than twice the shutdown time
Operation EnvironmentTemperature: 10 ~ 40°C
Humidity: 20% R·H ~ 85% R·H, non-condensing
Storage EnvironmentTemperature: -20°C~70°C
Humidity: < 95% R·H, non-condensing
Communication InterfaceRS232×1, LAN×1, USB×1
Screen8.4 inch color LCD display
Dimensions390 mm (W) × 270 mm (D) × 180 mm (H), without feets

 
 
WeightAbout 10 kg
 