Gcan Codesys PLC Intelligent Controller with Analog Input and Output for Cement Plant Dust Collection

Min.Order: 1
Product origin: Shenyang, Liaoning, China
Infringement complaint: complaintComplaint
US$ 269

Description
 
Total 3 control modules
Honey! Please confirm your detailed requirements before payment, GCAN-PLC itself does not contain any IO points, if you need different IO modules, please contact us.
GCAN-PLC is a modular and scalable PLC module. It consists of a programmable main control module, several I/O modules and a terminal terminal module. Each module communicates with each other using an internal bus, and the user can program and control each I/O module independently. It can be used in almost any industrial field control and acquisition system.
ModelCharacteristicCommunication bus
GCAN-PLC-400CPU frenquency 168M1*CAN+1*Ethernet+
1*RS232(or RS485)
Program storage:16M byte
Data storage:512K byte
GCAN-PLC-510CPU frenquency 400M1*CAN+1*Ethernet+
1*RS232(or RS485)
Program storage:32M byte
Data storage:16M byte
GCNA-PLC-511CPU frenquency 400M1*CAN+1*Ethernet+
1*RS232+1*RS485
Program storage:32M byte
Data storage:16M byte

Total 2 communication modules
Note: GCAN-IO-8000/8100 is not a PLC main control module, but a remote IO module. GCAN-IO-8000 is a CANopen adapter, and GCAN-IO-8100 is a Modbus RTU adapter.
ModelCharacteristicCommunication bus
GCAN-IO-8000Protocol:CANopen1*CAN
Number of Nodes:1~127
Baud rate:10K~1000K
Maximum IO module:32
GCAN-IO-8100Protocol:Modbus TCP/RTU1*Ethernet+
1*RS232+1*RS485
Number of Nodes:1~247
Baud rate:600~115200
Maximum IO module:32
 
PerformanceCANopen adapter (GCAN-IO-8000)Modbus adapter (GCAN-IO-8100)
Node number1~1271~247
Baud rate10Kbps~1000Kbps600bps~115200bps
Power input24V DC (18~36V)
Insert I/O module number32 pieces (at most 32*8 IO point)
Dimension100mm*69mm*48mm
Working temperature, humdidness-40ºC~+85ºC, 0~90%RH, without condensation
IP gradeIP20
Module feature•  Standard CANopen slave station

•  Support 4 TPDO, 4 RPDO

•  Support 1 SDO, 1 emergency object, 1
  node error control object

•  Start to perdefine connection, suppor
  parameters store

•  PDO mode supports synchronization,
  looping, event-driven, polling

•  Configuration mode is automatic
  configuration

•  CAN interface: one open 4 terminal

•  Input current, 70mA+ ( total GC-bus
  current), maximum 2.5A

•  Starting current: about 2.5 times
  continuous current

•  Power contacts: maximum 24V
  DC/maximum 10A

•  Electrical isolation: 1500 Vrms
•  Support standard Modbus protocol, a standard Modus slave station

•  Support Modbus function code:01, 02, 03, 04, 05, 06, 15, 16

•  Support CRC validation

•  Support Modbus TCP, Modbus RTU communication (corresponding to two kinds
  of style)

•  RS485 interface adopts standard two-wires system

•  Serial interface baud rate supports 600bps~115200bps, configured by serial
  interface

•  The maximum number of bus terminals module is 64

•  Configuration mode is automatic configuration, expandedfreely

•  Ethernet interface supports static or dynamic IP acquisition

•  Ethernet interface supports heartbeat and timeout disconnection

•  Ethernetwork interface is fixed, target IP and target interface can be set

•  Automatic restoration of connection resources after the Ethernet interface is
  disconnected,and reliable establishment of TCP connections

•  Ethernet interface is compatible with the SOCKET working mode (TCP Server,       TCP Client,UDP, etc.). The upper computer communication software complies         with the standard SOCKET rules.

•  Input current, 70mA+ (total GC-bus current), maximum 4500mA

•  Starting current: about 2.5 times continuous current

•  Power contacts: maximum 24V DC/maximum 10A

•  Electrical isolation: 1000 Vrms (power contact/bus coupled powervoltage)

•  Standard DIN rail,designed for industrial design

Input and output modules
 
I/OTypeCharacteristicSignalChannel
DigitalGC-1008Digital input(PNP)24V DC8-channel
GC-1018Digital input(NPN)24V DC8-channel
GC-1502Counter(200kHz max)-2-channel
DigitalGC-2008Digital output(PNP)24V DC8-channel
GC-2018Digital output(NPN)24V DC8-channel
GC-2204Relay output-4-channel
GC-2302PWM(20Hz~200kHz)-2-channel
Analog inputGC-3604Voltage input, 16 bits-5~+5V4-channel
GC-3624Voltage input, 16 bits10V~+10V4-channel
GC-3644Current input, 16 bits0-20mA4-channel
GC-3654Current input, 16 bits4-20mA4-channel
GC-3664Voltage inptu, 16 bits0~+5V4-channel
GC-3674Voltage input, 16 bits0~+10V4-channel
GC-38042-wire PT100, 16 bitsThermal resistance4-channel
GC-38142-wire PT1000, 16 bitsThermal resistance4-channel
GC-38223-wire PT100,16 bitsThermal resistance2-channel
GC-38323-wire PT1000,16 bitsThermal resistance2-channel
GC-3844K type thermocoupleThermocouple4-channel
GC-3854S type tyhermocoupleThermocouple4-channel
GC-3864T type thermocoupleThermocouple4-channel
GC-3874J type thermocoupleThermocouple4-channel
Analog outputGC-4602Voltage output, 16 bits-5V~+5V2-channel
GC-4622Voltage output, 16 bits-10V~+10V2-channel
GC-4642Current output, 16 bits0-20mA2-channel
GC-4652Current output, 16 bits4-20mA2-channel
GC-4662Voltage output, 16 bits0-5V2-channel
GC-4672Voltage output, 16 bits0-10V2-channel
GC-4674Voltage output, 12 bits0-10V4-channel
Special moduleGC-6101RS232/RS485 extension--
GC-6201GPRS extension--
GC-6501WIFI extension--
GC-8012Power extension--
 

Fast system response

GCAN-PLC series uses the German enbedded real-time kernel system,which not only has strong real-time performance and processing ability,but also supports users to program with the 5 programming languages specified in IEC 61131-3 standard,including SFC,LD,FBD,ST and IL.Flexible use of familiar programming languages can shorten the project development cycle.

Integrate three Interface

 
GCAN-PLC series has been integrated with RS232,Ethernet and CAN,three common industrial fieldbus communication interface,which can be programmed to realize the bus communication and networking.if users want to realize Modbus,CANopen and other communication protocols ,we will provide users with sample programs for their reference.

Extend IO number randomly

GCAN-PLC series can extend the amount of IO module according to the users actual needs.Up to 256 modules canbe extended.users can freely choose the type of IO,such as:analog quantity module,digital quantity module ,etc.GCAN-PLC series is very small size,users can extend a variety of functions in a compact space.Can meet the need of different customers.
 
Packing

After-sale service

Our main products are all independent research and development.We provide one year free after-sales warranty,lifetime free software and technical support if you have any question,our after-sales engineer will answer for you,please feel free to purchase.
Product Tag:
Related categories: