75W 110V 220V AC to DC 12V 6A DIN Rail Power Supply

Min.Order: 10
Product origin: Wenzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 19.54 ~ 20.56

Description
 
Product Description

Product Parameters
MODELNDR-75-12NDR-75-24NDR-75-48
DC VOLTAGE12V24V48V
RATED CURRENT6.3A3.2A1.6A
CURRENT RANGE0 ~ 6.3A0 ~ 3.2A0 ~ 1.6A
RATED POWER75.6W76.8W76.8W
RIPPLE & NOISE (max.)80mVp-p120mVp-p150mVp-p
VOLTAGE ADJ. RANGE12 ~ 14V24 ~ 28V48 ~ 55V
VOLTAGE TOLERANCE ±2.0%±1.0%±1.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±1.0%±1.0%±1.0%
SETUP, RISE TIME1200ms, 60ms/230VAC 2000ms, 60ms/115VAC at full load
HOLD UP TIME60ms/230VAC 12ms/115VAC at full load
VOLTAGE RANGE90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]
FREQUENCY RANGE47 ~ 63Hz
EFFICIENCY85.50%88%89%
AC CURRENT1.45A/115VAC 0.9A/230VAC
INRUSH CURRENT20A/115VAC 35A/230VAC
LEAKAGE CURRENT<1mA / 240VAC
OVERLOAD105 ~ 130% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE14 ~ 17V29 ~ 33V56 ~ 65V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATUREProtection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.-20 ~ +70ºC (Refer to "Derating Curve")
WORKING HUMIDITY20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +85ºC, 10 ~ 95% RH
TEMP. COEFFICIENT±0.03%/ºC (0 ~ 50ºC)
VIBRATIONComponent:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
WITHSTAND VOLTAGEI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25ºC/ 70% RH
EMC EMISSIONCompliance to EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A, EAC TP TC 020
MTBF486.2K hrs min. MIL-HDBK-217F (25ºC)
DIMENSION32*102*125.2mm( L*W*H)
PACKING0.51Kg; 28pcs/15.3Kg/1.22CUFT
NOTE 
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it  still meets EMC directives.