Battery Pack Performance Specifications | |
| Rated voltage | 51.2V | |
|
| Rated capacity | 100Ah | |
| Rated energy | 5120Wh | |
| maximum continuous | 5kW | |
| power |
| Maximum number of parallel connections | | |
| RS485: 15 | |
| Series connection | Prohibit | |
| BMS Model | 16S100A | |
| | Over-charge protection;Over-discharge | |
Electrical Characteristics | BMS Function | protection;Over-current protection;short | |
| | circuit protection;Temperature protection | |
| | and balance function | |
| Heating Function | Optional | |
| Communication | RS232;RS485;CAN (Optional) | |
| Cycle life | ≥2000 cycles (0.5Ccharge and discharge, | |
| 80%DOD ,60%EOL ,25C) | |
| Equalizing voltage | 56V | |
| Float voltage | 55.2V | |
| Standard charging | 20A/1000W | |
Charging characteristics | current/power |
| Max charging | 50A/2500W | |
| current/power |
| Standard discharging current/power | 20A/1000W | |
| Max discharging | 100A/5000W | |
Discharging characteristics | current/power |
| Discharge end of voltage | 43.2V | |
| Size (W×D×H) mm | 440×470×156 (19inch 3.5U) | |
| Shell material | metal housing | |
Mechanical characteristics | Weight | About 50Kg | |
| Waterproof Rating | IP20(indoor use ) | |
Temperature | Charge temperature | 0C to 50C | |
characteristics | Discharge temperature | -20C to 55C | |
| Best performance | 10C to 40C | |
temperature |
| Storage temperature | ≤ 35C,50%SOC ,6 months | |
BMS parameters | |
No | | | The reference standard (the |
Item | Detail | set value is subject to the |
| | actual set value) |
| | Cell overcharge alarm voltage | 3.50~3.90V |
| Overcharge | Overall overcharge alarm voltage | 56.40V~57.60V |
1 | protection | Cell overcharge protection voltage | 3.50~3.90V |
| | Overall overcharge protection voltage | 56.40V~57.60V |
| | Cell over discharge alarm voltage | 2.0V~2.90V |
| Over discharge protection | Overall over discharge alarm voltage | 36.00V~48.00V |
2 | | Over discharge protection voltage | 2.0V~2.90V |
| | Overall over discharge protection voltage | 36.00V~48.00V |
| | Protection conditions | External circuit short circuit |
| |
| |
| Short circuit protection | Delay time | ≤1mS |
3 | | | Cut load. If a short circuit is |
| | | triggered multiple times, it is |
| | Release condition | locked into a protected state. |
| | | After the user needs to check |
| | | the external circuit, reset the |
| | | BMS and release the protection. |
| | Battery high temperature warning | 35C~65C |
| Temperature protection | Battery high temperature protection | 35C~65C |
4 | | Battery low temperature warning | -20C~0C |
| | Battery low temperature protection | -20C~0C |
| | Balance turn-on voltage | 3 45V±0 02V |
5 | Charge balance | Balance turn-on voltage difference | 20mV |
| | Balance current | 85mA±20mA |
6 | Communication | RS232/RS485 | Default baud rate is 9600bit/S |
| Power | Circuit consumes current while working | ≤50mA |
7 | consumption | Sleep mode consumes current | ≤300 μA |