Model | SUN-5K-SG01LP1 | SUN-6K-SG01LP1 | SUN-7.6K-SG01LP1 | SUN-8K-SG01LP1 |
Battery Input Data |
Battery Type | Lead-acid or Lithium-ion |
Battery Voltage Range (V) | 40~60V |
Max. Charging Current (A) | 120A | 135A | 190A | 190A |
Max. Discharging Current (A) | 120A | 135A | 190A | 190A |
Charging Curve | 3 Stages / Equalization |
External Temperature Sensor | Optional |
Charging Strategy for Li-Ion Battery | Self-adaption to BMS |
PV String Input Data |
Max. DC Input Power (W) | 6500W | 7800W | 9880W | 10400W |
PV Input Voltage (V) | 370V (100V~500V) |
MPPT Range (V) | 125V-425V |
Start-up Voltage (V) | 150V |
PV Input Current (A) | 11A+11A | 22A+11A | 22A+22A | 22A+22A |
No.of MPPT Trackers | 2 |
No.of Strings Per MPPT Tracker | 1+1 | 2+1 | 2+2 | 2+2 |
AC Output Data |
Rated AC Output and UPS Power (W) | 5000W | 6000W | 7600W | 8000W |
Max. AC Output Power (W) | 5500W | 6600W | 8360W | 8800W |
Peak Power (off grid) | 2 times of rated power, 10 S |
AC Output Rated Current (A) | 20.8A | 25A | 31.7A / 33A | 33.4A / 35A |
Max. AC Current (A) | 22.9A | 27.5A | 34.9A / 36.3A | 36.7A / 38.5A |
Max. Continuous AC Passthrough (A) | 35A | 40A | 50A | 50A |
Output Frequency and Voltage | 50 / 60Hz;208Vac (2 / 3 phase), 230Vac (single phase) |
Grid Type | Single Phase |
Current Harmonic Distortion | THD<3%(Linear load<1.5%) |