LED Barrier Radar Motion Sensor Vehicle Detector Sensor Alternative to Loop Detector

Min.Order: 2
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 1 ~ 78

Description




1. Are you still troubled to install loop detector and loops?
   1) Cutting ground-Waste time and not good looking;
   2) Complex wiring-Messy and Difficult;
   3) Mud road-Cannot fix the loop;
   4) Cannot detect big truck, trailer or other vehicles with high-bed.

2. Why choose barrier radar detector?
   1) Can replace loop detector completely; no wiring layout, save time and cost.
   2) Easy installation; Easy parameters setting; Adjustable distance from 1 to 6m.
   3) Work in range of 24-24.5Ghz without effects from any climatic environment.
   4) Can effectively distinguish vehicles and humans to avoid any hitting.
   5) Can be used for trigger detection, e.g. trigger camera to capture the picture.
   6) Can be used to trigger the alarm in the warning zone.
   7) Can record the traffic and no data is lost when power is off.

3. Application
  1) Regional detection and triggering in various climatic environments.
  2) Anti-hitting and trigger applications for all types of barriers gates.
  3) Suitable for mixed channels of personnel and electric vehicles.
  4) Suitable for vehicle access detection for fast rolling doors(only vehicles can be detected).

4. Technical Parameters
  1) Input Voltage: 12VDC
  2) Rated Current: 250mA
  3) Working Frequency: 24-24.25GHz
  4) Modulation Mode: FMCW
  5) X-axis Antenna Transmission Power: 10-15dBm
  6) X-axis Horizontal Beam: 35°±5°
  7) X-axis Vertical Beam: 15°±3°
  8) Y-axis Antenna Transmission Power: 10-15dBm
  9) Y-axis Horizontal Beam: 15°±3°
 10) Y-axis Vertical Beam: 35°±5°
 11) Z-axis Detection Distance: 0.5 to 6 meters, ±0.1 meters
 12) Working Temperature: -40ºC~+85ºC
 13) Protection Level: IP67
 14) Dimension: 127*97*26mm


5. Quick Setting (Required Setting Items)
  1) Straight pole lane application settings (Only 2 steps required)
  2) Fence lane application setting (Only 3 steps required.
  3) Trigger Mode Setting (Only 3 steps required)

6. Wiring Definition

ColorDefinition
RedPower Input +12VDC
BlackPower Input GND
BlueRelay Output NC
WhiteRelay Output COMConnect to "Loop Detector" signal on barrier controller
YellowRelay Output NO
GreenGate Opening Input (Recommend)


7.CE, UKCA and ROSH Certificate