Model No. | DX-SSL-Y | ||
Light Source | 300W | 400W | 500W |
Capacity | 3.2V 50AH | 3.2V 70AH | 3.2V 90AH |
Solar Panel Power | 6V 60W | 6V 80W | 6V 100W |
Solar Panel | high efficiency monocrystalline | high efficiency monocrystalline | high efficiency monocrystalline |
Human Induction (PIR Sensor) | Yes | Yes | Yes |
Product Size | 887X400X280mm | 1160X400X280mm | 1435X400X280mm |
Net Weight | 10.4Kg | 11.8Kg | 14.6Kg |
Holder (mm) | 60mm | ||
Lighting Angle | 70 X140° | 70 X140° | 70 X140° |
Color Temperature | 6000k-6500k | 6000k-6500k | 6000k-6500k |
Packaging | 1035X450X115mm | 1315X450X115mm | 1585X450X115mm |
Working Time | ≥24Hr | ≥24Hr | ≥24Hr |
Working Temperature | Charging: -20°C~+60°C Discharge: -20°C~+60°C Storage Temperature: 0°C~+45°C | ||
Recommended Mounting Height | 9-10m | 10-12m | 12-13m |
Recommended Mounting Distance | 25-30m | 30-35m | 35-40m |
| Cause | Inspection methods | Solution |
Lights not work | Switch does not turn on | Check whether the switch turns on | Turn on the switch |
Switch failure | Make the switch short circuit, if it is still lighting up, could judge the switch failure. | Replace Switch | |
Battery runs out | Long rainy day or wrong installation site could not charge enough power. Open the system, disconnect the battery and use multimeter to check the voltage of the battery, if voltage less than 11V, then could judge battery runs out or low power cause system could not work. | Charge battery by solar panel in daytime, and turn off the switch at night to stop discharge, like this, 2 days could full charge the battery. | |
LED Failure | Firstly, adjust the DC power supply to voltage 9V and current less than 1A, then connect the positive and negative electrode of DC power supply to LED, if LED could not light, could judge LED failure. | If confirming LED failure, please contact us to return and replace. | |
Short lighting time | Low battery | Wrong installation or dust and leaves cover on solar panel cause not enough solor power to battery. 1. Check whether there is dust or leaves covering on the solar panel. 2. Open the system, disconnect the battery and use multimeter to check the voltage of the battery, if voltage less than 11V, that could judge battery runs out or low power cause system could not work. | 1. Charge battery by solar panel in daytime, and turn off the switch at night to stop discharge, like this, 2 days could full charge the battery. 2. Clean the solar panel. |
Battery Failure | Open the light and check if battery is dispalced or outer has been damaged . Battery maturing, lights used more than 2 years. | 1. If damage caused by transportation, please return to our factory for repairing or replacement. 2. Contact us to buy the same type battery if battery maturing. | |
No induct | Sensor Failure | Move in the range of detection under the half power lighting condition, if light not turns to full power ,could judge the sensor failure. | If confirming failure caused by controller or sensor, please return to our factory for repairing or replacement. |
Flashing light | Controller (timer) setting wrong | Intelligent mode opens due to an exceeding output power of the controller and light flashing. | Return to our factory to reset or replace the products. |