Technical parameter:
1.Advanced technology of WUDIN
Optimal design of flow and heat transfer in high efficiency heating loop
Professional design team for performance optimization design
2.Optimum control with WUDIN Intelligence
Unique dynamic optimization and control algorithms
Complete safety protection design
High efficiency and energy saving operation strategy design
Technical service
1, We calculate the referigeration capacity and recommend the best models.
2, We design and develop the new products according to your requirement(Customized).
3, We supply the professional refrigeration technical support and electronic technical support for your installation, debugging and operation.
4, We supply the spare parts and technical support in & after the warranty time.
5, We supply the training course to your workers at our factory if you need.
After sale service
1. One-Year guarantee for whole unit and all parts free
2. Life time maintenance
3. Machines are strictly tested before delivery and are delivered with firm & reliable packing.
4. 24 hours on line service.
Thermo-L30-12 Oil Mold Temperature Controller | |||
No. | items | Technical Parameters | |
1 | Type | Type | Thermo-L30-12 |
Power supply | 380V,50HZ,3 phase | ||
media | Oil | ||
control method | Microcomputer self -optimizing processor | ||
Temperature control | PID ±1ºC | ||
Temperature range | Max.200ºC | ||
Heating power | 12KW | ||
2 | Oil Pump | Power | 2.2kw |
Flow | 233 L/min | ||
Head | 28m | ||
3 | Heating method | Direct Heating | |
4 | Piping | Hot Media Export | DN25 (Customized) |
Hot media entrance | DN25 (Customized) | ||
5 | Heat exchanger | Tube heat exchanger | 0.1 m² |
Cooling water outlet | DN15 | ||
Cooling water inlet | DN15 | ||
Oil drain | DN15 | ||
6 | Thermostat | Type | PT100 |
Thermometer | K type thermocouple | ||
Show status | Set value and actual value are displayed separately | ||
Choice of contribution | Relay output | ||
7 | Safety protection device | Abnormal temperature | Circulating oil temperature exceeds the upper limit and cut off the main power supply |
Power supply reverse phase | Power phase detection prevents pump reversal and alarm indication | ||
Pump overload | Thermal relay protects pump overload and alarm indication | ||
Oil shortage protection | The oil level is detected to prevent oil shortage | ||
Pipe blockage | BY-PASS pressure relief circuit | ||
Abnormal pressure | Abnormal system pressure automatically stops heating | ||
Short circuit | Air switch-trip | ||
8 | Oil Tank | Volume | 20 L |
9 | Weight | Total | 80 KG |
10 | Size | L*W*H | 900*420*850(mm) |