Three Phase Simultaneous Measurement Transformer Winding Sweep Frequency Response Analyzer

Min.Order: 1
Product origin: Xi'an, Shaanxi, China
Infringement complaint: complaintComplaint
US$ 7000 ~ 8000

Description

XHBX1501S Transformer winding deformation tester
SFRA Test kit transformer
 (Three phase simultaneous measurement)


Product description

Transformer winding deformation tester based can make accurate diagnosis on the transformer internal fault based on the measurement of the characteristic parameters of transformer windings inside, using the frequency response analysis (FRA) method developed and improved by the developed countries.
It applies to the detection of internal structure fault in 63kV-500kV power transformers.

 

Main features

1. The test can be carried out without lifting the cover and disassembling the transformer.

2. Adopt the most popular sweep method to measure.

3. This instrument can measure transformers those are above 6kV.

4. It uses a split structure, test host and the host computer were connected by USB or network connection, it can use freely when it was plugged.

5. The field wiring is simple, easy to use.

6. Measuring dynamic range: -100dB ~ 20dB.

7. The analysis software is powerful, and the software and hardware indicators meet the national standard DL/T911-2004.

8. Sweep measurement using linear or logarithmic distribution.

9. The response channel has multiple ranges and automatically adjusts the range during the measurement process.

 

Main Technical Parameters

 Scan mode:

  1. Linear scanning distribution
    Scanning measurement range: (10Hz) - (10MHz) 40000 scanning point, resolution 0.25kHz, 0.5kHz and 1kHz
  2. Segment frequency scanning measurement distribution
Frequency scanning measurement range: 
(0.5kHz)-(1MHz),2000scanning points;
(0.5kHz)-(10kHz)
(10kHz)-(100kHz)
(100kHz)-(500kHz)
(500kHz)-(1000kHz)

 Other technical parameters:

  1. Amplitude measurement range (-120dB) to (+20 dB)
  2. Amplitude measurement accuracy: 0.1dB
  3. Scanning frequency accuracy: 0.01%
  4. Signal input impedance: 1MΩ
  5. Signal output impedance: 50Ω
  6. Signal output amplitude: ± 20V
  7. Test repetition percent: 99.9%
  8. Measuring instruments dimensions (LxWxH) 300X340X120 (mm)
  9. Instrument's aluminum box size (LxWxH) 310X400X330 (mm)
  10. Overall weight: 13Kg
  11. Operating temperature: -10ºC to +40ºC
  12. Storage temperature: -20ºC to +70ºC
  13. Relative humidity: <90%, non-condensing

 

 
 













Product Tag:
Related categories:
Scroll to Top