Storage Battery Activator/Intelligent Storage Battery Activation Tester Lead Acid Battery Activator

Min.Order: 1
Product origin: Wuhan, Hubei, China
Infringement complaint: complaintComplaint
US$ 1300 ~ 2000

Description
Storage Battery Activator/Intelligent Storage Battery Activation Tester Lead Acid Battery Activator

I. Brief introduction

Uninterruptible power supply is the most basic guarantee in all the running equipment and network systems with increasing information and automation. Whether AC or DC uninterruptible power supply system, battery as a backup power supply plays an extremely important role in the system. When the battery is in the state of floating charge and standby, once the AC is out of power or other accidents, the battery becomes the only energy supplier of the load.

We know that in addition to the normal life cycle of the battery, some early failure of the battery occurs from time to time due to the quality of the battery itself, such as material, structure, process defects and improper use. In order to check the spare time and actual capacity of the battery pack and ensure the normal operation of the system, according to the maintenance rules of the power supply system, it is necessary to carry out regular or timely capacity check discharge tests to ensure the effectiveness of the whole battery cell by replacing the single cell which is found to be invalid or near failure at an early stage; or to evaluate the life expectancy of the whole cell.
Our company has developed for many years, with its proprietary technology, successfully serialized, intelligent and highly accurate single battery activator. The tester can be used as discharge load in the off-line state of battery, and the constant current discharge of the set value can be realized by continuously regulating the discharge current. During discharge, the instrument will automatically stop the discharge when the battery terminal voltage, or the monomer voltage, falls to the set lower limit, or the set discharge time, or the set discharge capacity, and record all valuable, continuous process real-time data.
This instrument has a very friendly man-machine interface.It not only can complete all kinds of settings and data query under the prompt of menu, but also the process data of discharge are stored in the memory of the equipment, which can be transferred to the U disk through the data interface.
 This instrument has perfect protection function, not only sound, light alarm, but also clear interface hint.


II. Main Features
  • Using high power winding resistance, the discharge current is more stable and fast
  • There is a USB interface to transfer the and discharge process data can be transferred to the U disk, and imported into the PC machine. PC data management software can analyze the process of battery discharge and generate corresponding data reports. Making data transfer easier.
  • Intelligent MCU ARM control ,7-inch touch LCD display in English . Simple menu operation.
  • Automatic protection function, set charge and discharge time , charge and discharge capacity , battery voltage below the set minimum protection voltage, load line abnormal automatic  and so on, the system can stop discharge and alarm, while automatically recording the mode of shutdown.
  • Various termination conditions, including termination voltage, discharge capacity, discharge time, to ensure the safety of discharge testing
  • Can set 10 automatic discharge-charge cycles
III.Technical Parameter
 
Applicated object lead-acid battery
Model typeA
Output voltage1.5~16V
Output current2V battery 0~100A;4/6V battery~60A;12V battery 0~30A
Work methodSingle use,Constant current mode
 protective value l Over-voltage protection at input end,LCD display;
l over-current protection,LCD display;
l 65ºC overheat protection,LCD display,buzzer alarm;
control accuracy Discharge current ≤±1%;Group terminal voltage≤±0.1%;Single voltage:≤±0.05%
Data storage capacity2Gbit  FLASH
Work environment
Heat dissipationair blast cooling
Temperatureworking range:-5~50ºC  reserve temperature :-40~70ºC
Humidityrelative humidity 0~90%(40±2ºC)
AltitudeRated altitude 4000 meter
Noise<60dB
working power supply
Voltage single-phase three wire system : 220V AC (-20%~+30%), frequency:45~65Hz;
 high-voltage insulation testInput - housing:2200Vdc 1min
Input-output:2200Vdc 1min
Output - housing:700Vdc 1min
SecurityEN610950
Wiring
 AC inputPower plug,Suitable for 1~1.5 mm2 cables
DC outputInstrument 25 mm2 cable quick plug (red positive, black negative
 
IV. After-sale Service
First Time Use guidance
For the first time use,  technical staff will guide customer how to make testing at site.

One Warranty

 The warranty period of all equipment is one year, lifetime maintenance.
During warranty period, free maintenance or replacement are provided timely for any quality problem . Finally we will afford customer a satisfactory solution, whether repair , replace or return it back .
Trouble-shooting   
fault that users can solve by themselves, we guarantee to give timely telephone guidance and bear the necessary cost .

If meet any fault not impossible to be solved by end-user, we will afford the best solution within 24 hours . Produce will be repaired within 10 days and delivery back to customer .



VII. Company profile

Wuhan Goldhome Hipot Electrical Co.,ltd is an ISO certificated factory specially for high voltage test equipment with nearly 20 years experience .

Our main featured products include: AC series resonant test device, GIS non-partial  discharge test system, AC / DC high voltage test set, primary current generator, multiple frequency generator ,multiple frequency induction voltage test device, vlf hipot tester, insulating tools (gloves,boots) dielectric  test set and other high voltage test equipment and testing instruments.