Wholesale/Supplier DC 5V 12V 24V 36V 48V 1A 2A 5A 10A 20A 30A 40A 50A 60A Switching Power Supply for LED Strip Light

Min.Order: 1
Product origin: Guangzhou, Guangdong, China
Infringement complaint: complaintComplaint
US$ 4.25 ~ 298.87

Description

Wholesale DC 5V 12V 24V 36V 48V 1A 2A 5A 10A 20A 30A 40A 50A 60A switching power supply for Led Strip Light 

I. FEATURES

1Support 0-5vdc / 0-12vdc analog signal external control switching mode 200w 0-200v 0-220v Variable dc power supply
2Adjustable with Compact size, light weight
3Wide range AC Input , AC input 110V/220Vac input selected by switch
4100% full load burn-in test
5Protection: Short circuit / Over load / Over voltage
6Fixed switching frequency at 25KHz
71 year warranty
8High efficiency, reliability quality, competitive cost
90-5Vdc / 0-10Vdc External control output (Optional)
10Extra adjustable potentiometer (Optional)
11Output voltage adjustable, output current be fix
 
II. COMMON SPECIFICATION
Adjustable range for dc voltageThe output voltage is 100% adjustable through the potentiometer
AC input voltage rangeAC 95-125V 60Hz | AC174-264VAC 50Hz Manual switch
Input current115V/2.11A | 230V/1.06A
AC in lash currentCold start current 25A/230V
leakage current≤1.5mA 230V AC
Overload protectionLoad more than 110%~120% switch to constant current mode
Over-voltage protection≥15% of output voltage
Setup rise hold time200ms  100ms  20ms
Vibration10-50Hz, 2G 10 minutes/cycle X, Y, Z axis each 60 minutes
Withstand voltageInput to shell 1500V/3mA AC | Input to output 1500V/3mA AC | Input to output 500V/3mA AC
working temperature-10ºC-65ºC,20%-90%RH
Storage temperature-10ºC--65ºC,20%--95%RH
Net weight0.8KG
Dimension200L*98W*42H(MM)
OTHERS
Output voltage tolerance1%
Wave and noise150mV P-P
Efficiency91%
III. MODEL INFOMRATION
MODELIPS-SPIPS-SP3.3-60IPS-SP4.2-60IPS-SP5-60IPS-SP12-29IPS-SP15-23.2IPS-SP24-14.6IPS-SP36-9.7IPS-SP48-7.3
OutputDC voltage3.3V4.2V5V12V15V24V36V48V
RATED current60A60A60A29A23.2A14.6A9.7A7.3A
Current Rated0-60A0-60A0-60A0-29A0-23.2A0-14.6A0-97A0-7.3A
Rated power198W252W300W348W348W350.4W349.2W350.4W
Ripple&Nosie(max)Note.2150mVp-P150mVp-P150mVp-P150mVp-P150mVp-P150mVp-P200mVp-P200mVp-P
Voltage adj,Range2.97-3.6V3.6-4.4V4.5-5.5V10.2-13.8V13.5-18V21.6-28.8V32.4V-39.6V43.2-52.8V
VOLTAGE TOLERANCE Note. 3±4.0%±4.0%±3.0%±1.5%±1.0%±1.0%±1.0%±1.0%
LINE REGULATION Note.4±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
LOAD REGULATION Note .5±2.5%±1.0%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
SETUP RISE TIME1500ms . 50ms / 230VAC 1500ms . 50ms / 115VAC at full load
HOLD UP TIME ( Typ .16ms / 230VAC 12ms / 115VAC at full load
INPUTVoltage range90-132VAC /180-264VAC by switch  240VDC~370VDC(switch on 230VAC)
Frequency range47~63Hz
Efficiency (typical)79.5%81.5%83.5%85%86%88%88.5%89%
Ac current(Typ.)6.8A/115VAC 3.4A/230VAC
INRUSH CURRENT(TyP.)60A/115VAC 60A/230VAC
LEAKAGE CURRENT(TyP.)< 2mA / 240VAC
PROTECTIOOVER LOAD110-140% rated output power
Protection type Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGEProtection type: Shut down olp voltage, re-power on to recover
3.8-4.45V4.6-5.4V5.75-6.75V13.8-16.2V18-21V28.8-33.6V41.4-46.8V55.2-64.8V
OVER TEMPERATUREHiccup mode, recovers automatically after fault condition is removed
FUNCTIONFAN ON/OFF CONTROL(Typ.RTH3≥50ºC FAN ON,≤40ºC FAN OFF
ENVIRONMENTWORKING TEMP-30-+70C( Refer to "Derating Curve")
WORKING HUMIDITY20-90% RH non-condensing
STORAGE TEMP.  HUMIDITY-40~+85ºC. 10~95%RH
STORAGE TEMP.  HUMIDITY40~+85ºC,10~95%RH
TEMP.  COEFFICIENT±0.03%/ºC(0-50ºC)
VIBRATION0-500HZ, 5G 10min /cycle, 60min.  each along X, Y, Z axes
SAFETYSAFETY STANDARDSUL60950-1 approved
WITHSTAND VOLTAGE1/P-O/P. 3KVAC I/P-FG: 2KVAC O/P-FG: 0.5KVAC
ISOLATION RESISTANCEV/P-O/P LP-FG O/- FG: 100M Chms/500VDC /25C/70%RH
OTHERSMTBF327 9K hrs min . MIL-HDBK-217F ( 25 C )
DIMENSION215*115*30MM(L*W*H)
PACKING 
NOTE1 . All parameters NOT specally menod are measured a 230VAC nu ed ad and 25 of ament temperature2 Rple & nose are measure a 0MHZ of bawh g a 1w w m wh a 4 l acor3 . Tolerance incudes set up tolerance , line regulation and load regulation .Line regulation is measured from low line to high line at rated load5 . Load regulation is measured fromm % to 1000% rated load6 . Length of set u time is measured at old st a T N OFF he power supply very quicky may lead to increase of the set up7 . The 150 % peak oad capab s i i for o s for 12-48 5 w n r h p mode if the peak load s deliveredfor over 1 second and will recover once ites to the rated current level ( 1 15VAC / 230VAC )8 . The ambient meare dea of 5 / 1000 is ded or oea aude greater han 2000m ( 6500ft

 