Model | 2001-D-1 Titrate stand |
Configuration | HD-300S Nucleic acid protein detector HL-2F The constant flow pump BSZ-100 partial collector |
Column | 1.0x50cm,1.0x70cm,2.6x50cm,each for one |
OD value | New microcomputer chip control, show three OD value, the user directly read the optical density A value |
Wave length | 220nm(optinal),254nm,280nm,340nm(optional) |
Measuring range | Optical :4nm,volume:80ul |
Test tube number | Set the starting tube arbitrarily, each tube corresponds to a number, to ensure that the tube is accurately matched |
Test tube display | Test tube:100 pieces,Each tube has a larger capacity,12ml super large blue film LCD original extremely clear display. |
Timer | 1~199h59min59s |
Flow rate | 2x(0.5-900)ml/h |
speed adjustable range | 0-65r/min |
Partial filling | Manual subassembly and filling. |
Software | Computer graphics, data analysis, calculation and printing. |
Model | 2001-D-2 Titrate stand |
Configuration | N2000 Nucleic acid protein detector. DHL-B The constant flow pump DBS-100 Partial collector TH-500A Gradient mixer |
Column | 1.0x50cm,1.0x70cm,2.6x50cm,each for one |
OD value | New microcomputer chip control, show three OD value, the user directly read the optical density A value |
Wave length | 220nm(optinal),254nm,280nm,340nm(optional) |
Measuring range | Optical :4nm,volume:80ul |
Test tube number | Set the starting tube arbitrarily, each tube corresponds to a number, to ensure that the tube is accurately matched |
Test tube display | Test tube:100 pieces,Each tube has a larger capacity,12ml super large blue film LCD original extremely clear display. |
Timer | 1~199h59min59s |
Drops setting | 1-9999 drops |
Peak range | 0-100mV |
Flow rate | 2x(0.5-900)ml/h |
speed adjustable range | 0-65r/min |
Partial filling | 1 sec~ 59 hours 59 min |
Gradient mix | 1000ml gradient |
Software | Computer graphics, data analysis, calculation and printing. |
Model | 2001-D-3 Titrate stand |
Configuration | HD-3001 Nucleic acid protein detector BT-100SD Constant flow pump DBS-100 Partial collector |
Column | 1.0x50cm,1.0x70cm,2.6x50cm,each for one |
OD value | New microcomputer chip control, show three OD value, the user directly read the optical density A value |
Wave length | 220nm(optinal),254nm,280nm,340nm(optional) |
Measuring range | Optical :4nm,volume:80ul |
Test tube number | Set the starting tube arbitrarily, each tube corresponds to a number, to ensure that the tube is accurately matched |
Test tube display | Test tube:100 pieces,Each tube has a larger capacity,12ml super large blue film LCD original extremely clear display. |
Timer | 1~199h59min59s |
Drops setting | 1-9999 drops |
Peak range | 0-100mV |
Flow rate | 1-14500ml/h |
Speed adjustable range | 0.1-150r/min |
Partial filling | 1 sec~ 9 hours 59 min 59 sec |
Software | Computer graphics, data analysis, calculation and printing. |
Model | 2001-D-4 Titrate stand |
Configuration | N3000 Nucleic acid protein detector. BT-100SD Constant flow pump CBS-B Partial collector |
Column | 1.0x50cm,1.0x70cm,2.6x50cm,each for one |
OD value | New microcomputer chip control, show three OD value, the user directly read the optical density A value |
Wave length | 220nm(optinal),254nm,280nm,340nm(optional) |
Measuring range | Optical :4nm,volume:80ul |
Test tube number | Set the starting tube arbitrarily, each tube corresponds to a number, to ensure that the tube is accurately matched |
Test tube display | Test tube:100 pieces,Each tube has a larger capacity,12ml super large blue film LCD original extremely clear display. |
Timer | 1~199h59min59s |
Drops setting | 1-9999 drops |
Peak range | 0-250mV |
Program mode | 1-10 mode |
Flow rate | 1-14500ml/h |
speed adjustable range | 0.1-150r/min |
Partial filling | 1 sec~ 59 hours 59 min |
Gradient mix | 1000ml gradient |
Software | Computer graphics, data analysis, calculation and printing. |