DW-TY-9900 ICP Emission Spectrometer Inductively Coupled Plasma Spectrometer laboratory Instrument ICP spectrometer Lab Metal Analysis ICP Spectrometer
 
 
Product Feature
Features
1.High-stability RF output, with stable light source and low detection limit that can reach the level of PPb(one billionth) at minimum.
2. The working curve has wide linear range that reach 5-6 orders of magnitudes.
3. Multiple elements are analyzed at the same time with fast analytical speed and wide range of applications. It can almost analyze all metallic and part of non-metallic elements in periodic table of elements.
4. Excellent optical system, advanced control system makes sure of the signal-background ratio accurate.
5. Imported key components: to ensure the accuracy and sensitively of the instrument.
6. Minimal matrix effect 99% of the sample without matrix separation.
7. Wide measuring range: ultra volume to the constant analysis.
8. Excellent precision: relative standard deviation RSD≤1.5%
9. Stability: the relative standard deviation RSD≤2.0%
10.Rapid analysis: sequential scan elements per minute, the fastest in more than 15.
11.Analysis of many elements: 70 metal elements can be analyzed and also some non-metallic elements.
12.Low detection limit: ug/L level
13.Do qualitative and quantitative analysis:
14.Convenience of analysis software: Window XP platform based on the third generation of China or English operating software to make it easier to use easily, the data processing system provides a variety of functions, the output data can be print.
15.TY-9900 ICP Spectrometer uses analysis software with convenient operations and powerful functions. It can also realize functions including measurement, data processing, correction and data output.

 
Technical Specification
Item Index
Analytical speed 10 elements every minute
Accuracy Relative standard deviation RSD≤2%
StabilityRelative standard deviation RSD≤3%(measured within one hour)
Measuring linear range(Relative coefficient)≥0.9995%
Low detection limitAs listed below for representative elements
 
ElementWavelength(nm)LOD(ppb &ug/L)ElementWavelength(nm)LOD(ppb &ug/L)
Ag328.068 0.3Nd401.225 1.5
Al396.152 2Ni221.647 1
As193.696 4Na588.99529
Au242.795 1P213.618 6
B249.773 1Pb220.353 5
Ba445.403 0.1Pd340.458 2
Be313.042 0.2Pr390.844 2
Bi223.061 5Re227.525 3
Ca396.847 0.2Rb780.023150
Cd214.438 0.3Sb206.833 6
Ce413.765 1.5Sc361.384 0.5
Co228.616 1Se196.026 8
Cr267.716 1Si251.611 5
Cu324.754 1Sm359.260 1
Dy353.170 0.3Sn235.484 10
Er337.271 0.3Sr407.771 0.15
Eu381.967 0.2Ta226.230 6
Fe238.204 1Tb350.917 1
Ga294.364 3Ti334.941 0.2
Gd342.247 0.5Tl261.861 5
Hf277.336 1Tm313.126 0.3
Ho345.600 0.5V309.418 0.5
La333.749 0.5W207.911 4
Lu261.542 0.2Y371.030 0.2
Mg279.553 0.2Yb328.937 0.2
Mn257.610 0.2Zn213.856 0.5
Mo202.030 1Zr343.823 0.4
Nb309.611 1K766.49060
   Cs455.53150000