10kv 11kv 35kv 2500kVA Hermetically Sealed Oil Type Distribution Power Transformer

Min.Order: 1
Product origin: Foshan, Guangdong, China
Infringement complaint: complaintComplaint
US$ -1

Description
Quick details:
Brand Name:ZHIBO
Model Number:S11-35KV series
Certification:ISO9001
Place of Origin:China 

Custom attributes:
Product Name:S11 series  Installation:Indoor/Outdoor
Rated Capacity:30~31500KVAVoltage:6kv-35kv
Number of Phases:Single or Three PhasesFrequency:50Hz/60Hz
Cooling:ONAN/ONAFCoil:Copper/Aluminum Coil
Insulation level:Class H/FCore:Cold Rolled Grain Oriented Silicon Steel Sheet

Product commerce clause:
Minimum Order Quantity:1Unit
Price:negotiation
Payment Terms:T/T ;L/C;USD
Supply Ability:500 units per month
Delivery Time:20 working days after received your payment
Packaging Details:plywooden box or nude, suitable to be delivered

Product Description:
Voltage Available: 10kV, 11kV, 20kV,22kV,33kV,35kV...
The heat dissipation of transformer coil in new type series transformer S9 & S11 uses new oil duct structure with reasonable design, optimizes the insulation technology and improves the mechanical strength and snti short circuit ability.  The core is made of high quality cold rolled sillcon steel, with five step lamination process, the surface coating curing paint to reduce the loss and noise. The apprearance is beautiful, easy and reliable operation.
Technical parameter:
GENERAL TRANSFORMER SPECIFICATION
GENERAL SPECIFICATION   
TRANSFORMER TYPE  Oil Type
INSTALLATION   Outdoor
APPLICABLE STANDARDS  IEC 60076
RATED POWER(ONAN)kVA2500
HIGH VOLTAGE kV 35 
HIGH VOLTAGE TAPPINGS (NO LOAD)%kV ±2x2.5 or ±5%
LOW VOLTAGE ( NO LOAD) kV 0.4
HIGH VOLTAGE INSULATION LEVEL(Um/UAC/ULI)kV 40/75/175
LOW VOLTAGE INSULATION LEVEL(Um/UAC/ULI)kV 1 , 1 / 3 / --
FREQUENCY HZ50 or 60
VECTOR GROUP  Dyn11
NUMBER OF PHASES  3
MAX. AMBIENT TEMPERATURE C40
MAX. TEMPERATURE RISE ( WINDING / OIL) C65 / 60
MAX. ALTITUDE ABOVE SEA LEVELL m1000
PERMISABLE SHORT CIRCUIT DURATION s2
GUARANTEED VALUES   
IMPEDENCE VOLTAGE (75C)±10% tolerance%6
NO LOAD LOSSES15% toleranceW2360
LOAD LOSSES (75C)15% toleranceW23200
    
STRUCTURAL SPECIFICATIONS   
HIGH VOLTAGE WINDING CONDUCTOR MATERIALS  Cu
LOW VOLTAGE WINDING CONDUCTOR MATERIALS  Cu
OIL TYPE  Mineral Transformer Oil
TANK MATERIALS  Steel Metal
DIMENSION and WEIGHT   
LENGTH /WIDTH / HEIGHT mmL / W / H 
TOTAL WEIGHT kg 
WEIGHT OF ACTIVE PART kg 
WEIGHT OF OIL kg 
    
CONNECTION TERMINALS   
HIGH VOLTAGE  Proclean Bushings  
LOW VOLTAGE Proclean Bushings  
    
ACCESSORIES   
HERMITICAL PROTECTION  RELAY  yes
PRESSURE RELIEF DEVICE  yes
OFF-CIRCUIT TAP CHANGER  yes
LIFTING LUGS  yes
OIL FILLING & DRAIN VALVES  yes
PS: the weight and dimension are ust for reference, please in kind prevail.

Winding & active parts:

Package for reference:

Logistics Delivery:

Company Profile:
 
      Our products are mainly including S9, S11, S13, SH15, SH16 series energy-saving oil-immersed transformers with 35kV and below voltages, which capacity are under 63000kVA; ZBW, YBW, YBM series combined substation; SC (B) 9, SC (B) 10, SC (B) 11 resin insulated low-loss dry-type transformers and SG (B) 10 series (H class) American DuPont NOMEX insulation transformers; ZS, ZSF series rectifier transformers, HSJ, HSSP series electric furnace transformers and so on.
     There are a number of
design experts in our company who could design according to the specific conditions of the equipment used by various steel companies, and they  are well experienced in the design of special rectifier transformers and other products for power supply power transformers used in steel rolling projects. It can also ensure that the design has sufficient large load short-term overload tolerance. For the design and manufacturing process of rectifier transformers, we pay more attention to the factors that may occur due to the frequent impact of current and voltage for a long time due to the steel rolling process. 
 Our  Factory:

Business Cooperation:

Certification:





Product Tag:
Related categories:
Scroll to Top