Item | Item Description | ||
Input Power Supply | Input Voltage | Three-phase 380V-15% ~415+10% | |
Frequency | 50/60Hz | ||
Adaptive Motor | Squirrel-cage three-phase asynchronous motor | ||
Starting Times | It is recommended not to exceed 20 times per hour. | ||
Control Mode | 1) Operation panel control; 2) Operation panel + external control; 3) External control; 4) External control + COM control; 5) Operation panel + external + COM control; 6) Operation panel + COM control; 7) COM control; 8) No start or stop operation. | ||
Start Mode | 1) Current-limiting start; 2) Voltage ramp start; 3) Kick start + current-limiting start; 4) Kick start + voltage ramp start; 5) Current ramp start; 6) Voltage current-limiting double closed-loop start. | ||
Stop Mode | 1) Soft stop; 2) Free stop. | ||
Protective Function | Open loop protection for external instantaneous stop terminals; 2) Over-heat protection for soft starter; 3) Protection for too long starting time; 4) Input open phase protection; 5) Output open phase protection; 6) Unbalanced three-phase protection; 7) starting over current protection; 8) Running overload protection; 9) Under voltage protection for power voltage; 10) Over voltage protection for power voltage;11) Protectionfor fault parameter setting; 12) Load short circuit protection; 13) Auto restart or incorrect wiring protection; 14) Incorrect wiring protection of external control stop terminals. | ||
Ambient | Place to be used | Indoor location with good ventilation free from corrosive gas and conductivedust. | |
Altitude | Below 3000M. It have to rise the rate power when the altitude is more than 3000M. | ||
Ambient Temperature | -30~+55 C | ||
Ambient Humidity | ≤90%RH without dew condensation. | ||
Vibration | <0.5G | ||
Structure | Protection Class | IP20 | |
Cooling Pattern | Natural wind cooling. |
Inverter Model | Power (kW ) | Current(A) | Packing Size (mm ) | Gross Weight (kg) | Net Weight (kg) |
ZJR2-3750 | 75kW 380V | 320A | 585*315*250mm/1PCS | 21kg | 20kg |
Model | Rated Power(KW) | Rated Current (A) | Outline Size | Install Size | Net Weight (KG) | ||||
H1 | W1 | D | H2 | W2 | d | ||||
ZJR2-3055/4055 | 5.5 | 11 | 270 | 145 | 159 | 245 | 130 | M6 | <3.5 |
ZJR2-3075/4075 | 7.5 | 15 | 270 | 145 | 159 | 245 | 130 | M6 | <3.5 |
ZJR2-3110/4110 | 11 | 22 | 270 | 145 | 159 | 245 | 130 | M6 | <3.5 |
ZJR2-3150/4150 | 15 | 30 | 270 | 145 | 159 | 245 | 130 | M6 | <3.5 |
ZJR2-3185/4185 | 18.5 | 37 | 270 | 145 | 159 | 245 | 130 | M6 | <3.5 |
ZJR2-3220/4220 | 22 | 44 | 270 | 145 | 159 | 245 | 130 | M6 | <3.5 |
ZJR2-3300/4300 | 30 | 60 | 270 | 145 | 159 | 245 | 130 | M6 | <3.5 |
ZJR2-3370/4370 | 37 | 75 | 270 | 145 | 159 | 245 | 130 | M6 | <3.5 |
ZJR2-3450/4450 | 45 | 90 | 270 | 145 | 159 | 245 | 130 | M6 | <3.5 |
ZJR2-Z3550/4450 | 55 | 110 | 270 | 145 | 159 | 245 | 130 | M6 | <3.5 |
Model | Rated Power(KW) | Rated Current (A) | Outline Size | Install Size | Net Weight (KG) | ||||
H1 | W1 | D | H2 | W2 | d | ||||
ZJR2-3750/4750 | 75 | 150 | 530 | 260 | 202 | 380 | 196 | M8 | <25 |
ZJR2-3900/4900 | 90 | 180 | 530 | 260 | 202 | 380 | 196 | M8 | <25 |
ZJR2-31150/41150 | 115 | 230 | 530 | 260 | 202 | 380 | 196 | M8 | <25 |
ZJR2-31320/41320 | 132 | 264 | 530 | 260 | 202 | 380 | 196 | M8 | <25 |
ZJR2-31600/41600 | 160 | 320 | 530 | 260 | 202 | 380 | 196 | M8 | <25 |
ZJR2-31850/41850 | 185 | 370 | 530 | 260 | 202 | 380 | 196 | M8 | <25 |
ZJR2-32000/42000 | 200 | 400 | 530 | 260 | 202 | 380 | 196 | M8 | <25 |
ZJR2-32500//42500 | 250 | 500 | 580 | 290 | 245 | 460 | 260 | M8 | <35 |
ZJR2-32800/42800 | 280 | 560 | 580 | 290 | 245 | 460 | 260 | M8 | <35 |
ZJR2-33200/43200 | 320 | 640 | 580 | 290 | 245 | 460 | 260 | M8 | <35 |
ZJR2-34000/44000 | 400 | 800 | 630 | 330 | 245 | 500 | 265 | M8 | <40 |
ZJR2-34500/44500 | 450 | 900 | 630 | 330 | 245 | 500 | 265 | M8 | <40 |
ZJR2-35000/45000 | 500 | 1000 | 760 | 406 | 260 | 540 | 370 | M8 | <45 |
ZJR2-36000/46000 | 600 | 1200 | 760 | 406 | 260 | 540 | 370 | M8 | <45 |