Fk-5112 Gaseous Flooding Fire Extinguishing System for Fire Protection

Min.Order: 2
Product origin: Hangzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 6900 ~ 11500

Description
FK-5112 Gaseous Flooding Fire Extinguishing System For Fire Protection
 
Product Description:

FK-5112 Novec 1230 Total Flooding Fire System, FK-5112 Novec 1230 clean gas automatic fire suppression systems, FK-5112 Novec 1230fire extinguishing system Pipe Network Type FM200 Fire Extinguisher
When the control mode selection key on the automatic fire alarm and fire extinguishing controller is set to the "auto" position, the fire extinguishing system is under automatic control. When a fire occurs in the protection area, the temperature and smoke detectors will send out a fire signal through the automatic fire alarm and extinguishing control After the logic analysis of the device, it sends out a combined sound and light alarm signal, and sends out a linkage command at the same time to close the linkage device. After a delay, a fire extinguishing command is issued, the starting valve is opened to release the starting gas, and the starting gas is opened through the control gas pipeline valves and container valves release the fire extinguishing agent and implement fire extinguishing.
 FM-200 / HFC -227ea
FK-5112 Novec 1230 is an odorless, colorless, liquefied compressed gas. It is stored as a liquid and dispensed into the hazard as a colorless, electrically non-conductive vapor that is clear and does not obscure vision. It leaves no residue and has acceptable toxicity for use in occupied spaces at design concentration. FK-5112 Novec 1230extinguishes a fire by a combination of chemical and physical mechanisms.FK-5112 Novec 1230 provides excellent fire protection in a wide range of applications from sensitive electrical equipment to industrial applications using flammable liquids. FK-5112 Novec 1230 agent is used in total flooding fire suppression systems.FM-200 does not work by displacing oxygen and is safe for use in occupied spaces without fear of oxygen deprivation.

Product Specifications:
 
ItemModelVolume(L) x Qty(unit)Maximum loading density of fire extinguishing agentStored Pressure (20ºC)Max Working Pressure(50ºC)Activate voltage/ currentOperating Temperature Range
1GQQ16/4.216X1≤1120kg/m34.2Mpa5.6MpaDC24 V/1.2A0ºC-50ºC
1GQQ32/4.232X1≤1120kg/m34.2Mpa5.6MpaDC24 V/1.2A0ºC-50ºC
1GQQ40/4.240X1≤1120kg/m34.2Mpa5.6MpaDC24 V/1.2A0ºC-50ºC
2GQQ70/4.270X1≤1120kg/m34.2Mpa5.6MpaDC24 V/1.2A0ºC-50ºC
3GQQ90/4.290X1≤1120kg/m34.2Mpa5.6MpaDC24 V/1.2A0ºC-50ºC
4GQQ100/4.2100X1≤1120kg/m34.2Mpa5.6MpaDC24 V/1.2A0ºC-50ºC
5GQQ120/4.2120X1≤1120kg/m34.2Mpa5.6MpaDC24 V/1.2A0ºC-50ºC
6GQQ150/2.5150X1≤1120kg/m34.2Mpa5.6MpaDC24 V/1.2A0ºC-50ºC
7GQQ180/4.2180X1≤1120kg/m34.2Mpa5.6MpaDC24 V/1.2A0ºC-50ºC
7GQQ250/4.2250X1≤1120kg/m34.2Mpa5.6MpaDC24 V/1.2A0ºC-50ºC
 
Product Details:


Components of FK-5112 Novec 1230 Fire Suppression Systems:

1. Storage cylinder: Cylinder, container valve (with pilot valve, pressure indicator), dip tube, etc.
2. High pressure hose: Connect cylinder valve and liquid check valve
3. Discharge Nozzle: Fitted at the end of pipe network to discharge fire suppressing agent
4. Control System: Control panel, smoke and heat detector, fire alarm, discharge indicator light, etc

Product Features:

1. Very swift fire suppression. Reach extinguishing level ≤10s.
2. Safe to people. People is safe when exposed at the FM200 gas discharge level.
3. Low extinguishing concentration. Nearly no obscure to vision in person evacuation.
4. Easy to clean. No residue left, and minimize damage to sensitive equipment.
5. Environment friendly. Zero ozone depletion potential and zero global warming potential.
6. Simple installation, with small storage space.


Working Drawing:
Novec 1230 & FM200 fire system devices are generally used in conjunction with fire detectors, fire alarm fire extinguishing controllers, emergency start/stop buttons, sound and light alarms, deflation indicators and other fire fighting equipment.
When a fire occurs in the protection area, the temperature and smoke detectors will send out a fire signal.

After the logic analysis of the automatic fire alarm and extinguishing controller, it will send out a sound and light composite alarm signal, and at the same time send out a linkage command to turn off the linkage equipment.
After a delay time, a fire extinguishing command is issued, the solenoid valve driver is opened, the container valve is opened, the fire extinguishing agent is released, and the fire is extinguished; if the duty officer discovers a fire, he can press the emergency start button outside the protective area door to implement the fire extinguishing operation ; There is also a manual button on the solenoid valve driver, and mechanical emergency manual operation can also be used to extinguish fire in an emergency.
Application:
* Electronic computer rooms
* Communication rooms
* Underground projects
* Offshore oil production platforms
* Libraries
* Archives
* Treasures warehouses
* Chemical combustibles warehouses
* Generator rooms
* Power distribution rooms

Our Workshop:
We also have Cabinet Type FK-5112 Novec 1230 Total Flooding Fire System, FK-5112 Novec 1230 fire extinguishing system Cabinet Type FM200 Fire Extinguisher

About PRI-SAFETY:

PRI-SAFETY specializes in the manufacture and exportation of Automatic Fire Systems, Throw Type Fire Extinguishers, CAFS Compressed Air Foam Fire Systems, Fire Extinguishers, Fire Hose Reels, Fire Hoses, Fire Cabinets, Valves, Pressure Gauges, Couplings, Smoke Alarms, Fire Blanket and other fire equipment, etc. We focus on providing one-stop fire-fighting products and professional service. 



We have attained ISO9001:2000, CE, EN3, EN1869 and EN694 certifications. Almost all products that we provide are manufactured and tested according to the international standard. We also supply OEM service, we can design and produce the products as client's special request.  

PRI-SAFETY also has very good after-sales service, we have one professional,high efficient and warmly sales team. We promise that all feedbacks from clients would be replied within 8 hours during working days. We always try our best to provide better service to meet our clients' demands.

Our company rule is saving time and cost for clients, taking good profit and well development for clients. We supply well growing space and training for each staff, help staffs to achieve their dreams. Then clients and staffs push our company development.


FAQ:

 1. Who are we?
We are based in Zhejiang, China, start from 2009,sell to Western Europe(39.36%),Africa(15.12%),Mid East(15.04%),Central America(12.33%),South America(10.03%),North America(4.01%),Northern Europe(2.56%),Southeast Asia(1.05%),Eastern Asia(0.50%). There are total about 11-50 people in our office.

2. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;

3. What can you buy from us?
Automatic Fire Suppression System,Tube fire system,CAFS Compressed Air Foam Fire System,Throwing Fire Extinguisher,Fire Extinguisher Accessoriers

4. Why should you buy from us not from other suppliers?
One Stop Fire Fighting Equipment supply and professional service. We have CE, EN3, EN671, EN1869 certificates. Mainly export to Europe, Middle east, South America, Africa,etc.

5. What services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW,Express Delivery;
Accepted Payment Currency:USD,CNY;
Accepted Payment Type: T/T,L/C,D/P D/A,Western Union,Cash;
Language Spoken:English,Chinese,Spanish


Scroll to Top