Parrel Connection Compressed Air Filter Particle Oil Water Mist Removal Qith Auto Drain

Min.Order: 50
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 225

Description
Welcome visit us!

As we know, the compressed air system contains kind of pollutants, such as water vapor, liquid water, particulate impurities, rust, pipe peeling, oil vapor, oil mist, liquid oil, microorganisms, etc .;

DT Series compressed air filter which could remove above pollution well and recommended for the industries in laser, medical, food and electronics etc.


Feature
a. Filter element made of fiber glass, serve life about 6000-8000hours, filter housing made of  aluminum alloy die-casting,serve life about 15 years.

b. Without tie-rod design and Circlip design, easy to replace the element.
c. Fixed lock design, easy to operate.

7 Grades Filter Element : PF/AO/AA/AX/ACS/AR/AAR



International test and measurement standard ISO12500

>ISO 12500 has made clear a general test and definition method for the compressed air filter manufacturers. The main performance
parameters are the air inlet oil content and particles size distribution of the solid particles.
>ISO12500-1 specifies the test requirements for the filtration performance of oil aerosol in the coalescing filter.
>ISO12500-2 specifies the test requirements of adsorption filters for the removal performance of steam adsorption.
>ISO12500-3 specifies the requirements for removal of particulate matter from solid pullutants.



Product are test with the international advanced testing equipment based on standard ISO12500, Which is equivalent to the standard ISO8573.1-2010 quality standard,  and provide filter performance test report.
Filtration Grade PFAOAAAXACSARAAR
Size of solid particles(ISO12500-3)5μm1μm0.01μm0.01μm-1μm0.01μm
Filtration performance of solid particles(ISO12500-3)-99.999+%99.999+%99.999+%99.999+%99.999+%99.999+%
Filtration performance of oil(ISO12500-1)50%80+%99.9+%99.99+%---
Residual oil content(ISO12500-1)5mg/m³0.6mg/m³<0.01mg/m³<0.001mg/m³<0.004mg/m³--

Technical Specification
The flow rate below is the treatment capacity of compressed air under rated working pressure 7bar g(100psi g).
For the application in other working pressure, please refer to the correction factors.
ModelPipe sizeFlow ratesDimension (mm)
L/Sm3/minscfmW(Width)D(Depth)H(Height)ABC(clearance for housing)
DT009RC1/4"5.0 0.3 10.6 80.669.0224.124.6173.950.5
DT010RC3/8"10.0 0.6 21.2 80.669.0224.124.6173.950.5
DT011RC1/2"20.0 1.2 42.4 108.293.3275.330.1220.653.3
DT012RC3/4"25.1 1.5 53.0 108.293.3275.330.1220.653.3
DT013RC1/2"30.1 1.8 63.5 108.293.3315.330.1260.653.3
DT014RC3/4"33.4 2.0 70.6 108.293.3315.330.1260.653.3
DT015RC3/4"46.8 2.8 98.8 133.0113.9399.640.7291.059.6
DT016RC1"60.1 3.6 127.1 133.0113.9399.640.7291.059.6
DT017RC1"80.2 4.8 169.4 133.0113.9468.440.7359.859.6
DT018RC1-1/2"100.2 6.0 211.8 133.0113.9468.440.7359.859.6
DT019RC1-1/2"125.3 7.5 264.8 133.0113.9533.740.7425.359.6
DT020RC2"200.0 12.0 424.0 170.0158.3783.152.9623.059.6
DT021RC2"266.7 16.0 565.3 170.0158.31065.452.9945.359.6
DT022RC2-1/2"316.7 19.0 671.3 170.0158.31065.452.9945.359.6
Technical requirementsMaximum operating pressure: 10 barg   Maximum operating temperature: 80°C     Minimum operating temperature:1.5°C
PressureBarg12345678910111213141516
Psig152944597387100116131145160174189203219232
Correction factor0.380.530.650.760.850.931.001.071.131.191.231.311.361.411.461.51
                                                               
Air Filter Picture
                         
Parallel Design   
                         
Without Tie-rod Design
                                   
Filter Element 
                     
YUKA Package

YUKA service:
a. Providing professional consultation, technical support and special solutions
b. Providing timely feedback on complaints
c. Providing perfect after sales service and warranty


Q:Why choose us?
a. 22 years' practical experiences in R&D and manufacturing Compressed air treatment;
b. Founder of Compressed Air Nation Standard GB/T30475.1-2013 and GB/T30475.2-2013;
c. ISO 9001:2015, CE and product follow ISO8573-1;
d. With Germany Imported high efficiency filtration Test Instrument;
e.All goods had been 100% test before dispatched.

 
Frequently Asked Questions:

Q1. What kind of your company is it?
We're the manufacturer integrated with R&D, production and sales.
 
Q2. How about your technical conditions and production capability?
Complete process documents and equipment, mass production. 500pcs filter per day.
 
Q3. What is the delivery time?
Delivery time depends on the order quantity, normally is 3-5 working days after 30% payment.
 
Q4. Do you have a warranty?
Yes, for filter, it is 1 year normally.
 
Q5. Can you supply customized product?
Yes, we have a professional technical team to provide you with the best solution and complete production processes and control to provide you with satisfied product.


Product Tag:
Related categories:
Scroll to Top