Anasthesia Machine Superstar Medical S6100d

Min.Order: 1
Product origin: Nanjing, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 3400 ~ 3600

Description

S6100 Anesthesia System

Application:

The Anesthesia machine makes a good performance in Intensive Care Units (ICU), Operation room, Anesthesiology Department and other departments. From high to low acuity, simple to complex cases, pediatric to geriatric patients,Superstar Medical Anesthesia Systems offer you the choices you need in ventilation, monitoring and technique. what's more, our expertise in anesthesia delivery and ventilation is based on rich 23-year history of developing anesthesia solutions that meet your needs. Good performance based on High Security, High Accuracy, High Stability and accurate monitoring.

 

Trust Points

Simplicity: easy to use, easy to move with 4 wheels.

Choice: adapt the equipment to your patients and procedures freely

Patient Centered Ventilation: Precision in an anesthesia ventilator, from conventional ventilation to advanced modes, including 3 modes: IPPV; A/C; SIMV.

Designed and manufactured by Superstar Medical with over 23 years experience in this area.

Flexible configurations to suit your needs.

International standard and advanced technology suitable for wide range use.

Compact interface and big screen give you better operating experience.

Over 3,500 units installed in the world.

 

Features

7" TFT LCD screen displays the Ventilation parameters, Alarming information and Waveform.

High precision flow meter, instantly know the fresh gas flow to your patient.

l Integration breathing circuit design, ensure easy operating and keep tidy.

Multiple working modes such as volume control and pressure limit, adapt to wide range patient.

Vaporizer with temperature, flow compensation and self-lock function, keep safety anytime.

Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects;

Real time pressure-time, flow-time loop graphics and high precision O2 concentration detection function included.

Vital sign monitor and Anesthetic gas monitor are optional.

 

 

 

Specification

 

Ventilation Modes

IPPV; A/C; SIMV;

Alarm and protection

Ventilator Parameter Ranges

The AC power failure alarm

Power failure or no connection

Flow Meter

O2(0.1 ~ 10L/min)

Internal battery backup low voltage alarm

<11.3±0.3V

 

N2O(0.1 ~ 10L/min)

No tidal volume

≤5Ml within 6s

 

 

High oxygen concentration alarm

19%-100%

Rapid Oxygen Supply

25L/min ~ 75L/min

Low oxygen concentration alarm

18%-99%

Tidal Volume(Vt)

0,20ML ~ 1500ML

High Airway  pressure alarm

20cmH2O-100cmH2O

Frequence

1bpm ~ 100bpm

Low Airway  pressure alarm

0cmH2O-20cmH2O

I/E

2:1 ~ 1:6

High Minute Volume alarm

Adult(5L/min-20L/min);

Paed(1L/min-15L/min

PEEP

0cmH2O ~ 30cmH2O

Low Minute Volume alarm

0-10L/min)

Pressure Triggering Sensitivity(PTr)

-20cmH2O ~ 0cmH2O 

 

 

Flow Trigger Sensitivity(FTr)

0.5L/min ~ 30L/min

Continuous Pressure alarm

(PEEP+1.5kPa) over 16s

 

 

Suffocation warning

5s-60s no spontaneous ventilation

SIGH

0(OFF)1/100~ 5/100

The maximum limited pressure  

<12.5 kPa

Apnea Ventilation

OFF,5s~ 60s

Fan error

Oxygen deficit

Show on screen

Show on screen

Pressure Limit

20cmH2O ~ 100cmH2O

Working conditions

Monitored Parameters

Gas source

O2,N2O

Frequence(Freq)

0 /min ~ 100 /min

Pressure

280kPa-600kPa

Tidal volume(Vt)

0 mL ~ 2000 mL

Voltage

100-240V

MV

0 L/min ~ 100 L/min

Power frequency

50/60Hz

Oxygen concentration

15 % ~ 100 %

Input Power

40 VA

Oscillographs Display

Packing Size

P-T(pressure - time)

Wooden Case Packing Size

L740*W800*1460mm

F-T(Flow - time)

G.W.

93KG

 

N.W.

66KG

 

Our Services

 

Packaging & Shipping

Company Information

FAQ

Product Tag:
Related categories:
Scroll to Top