UL508 TUV 40A 277VAC 12VDC Two Pole Dpst-No Miniature PCB Power Relay for EV Charger

Min.Order: 1
Product origin: Shanghai, China
Infringement complaint: complaintComplaint
US$ 4.125 ~ 6.1875

Description

Product Description

AC switching elements are a crucial part of safety and protection function in charging stations and PV system.

As an important part of the solar power generation system, the photovoltaic inverter can convert the DC current output generated from the photovoltaic panel into AC current, which can then be incorporated into the commercial grid or other off-grid power systems. In the grid connection interface, the electromagnetic relay on the AC side of the inverter plays a key role as a switching device to provide the necessary safe "open circuit" function.

IM-NE801A is a two-pole PCB power relay for new energy power generation(EV Charger, Solar Inverter, Energy Storage System). It features a high-capacity resistive switching load rating of 40A@277VAC for 50K cycles (@32A 230VAC) or 20K cycles (@40A 230VAC). The relay also features a mirror contact structure (compliant with EN60947-4-1) which uses a 2 Form A contact arrangement. IM-NE801A has a normally open contact gap of 3mm, which makes this relay VDE0126 compliant with European photovoltaic standards and meets the 4kV surge breakdown voltage between contacts required to be compliant with the EN61810-1 Industry standard.

The relay has short-time overcurrent characteristics, can withstand three times of 1000A 1ms overcurrent, and the contacts will not be damaged, and can continue to work normally to open and close.

Short-time overcurrent (an overcurrent carrying capacity)

SpecificationWeight≈70g
Continuous Current40A
Contact Form2A/2B
Contact MaterialAgSnO2
Max. Switching Voltage277VAC
Initial Contact Resistance10 (at 20A)
Insulation Resistance100MΩ,at 500VDC,50% RH
Electrical Endurance

50000 ops@32A 230VAC on-off ratio 1s:9s

20000 ops@40A 230VAC on-off ratio 1s:4s

Mechanical Endurance1*106 ops
Dielectric withstanding voltageAcross Open Contact4000VAC 1min
Coil to Contact801:3000VAC 1min
801A: 4000VAC 1min  
Pick-up & Release Time30ms. typical/10ms. typical
Environment TemperatureOperation:-40ºC~85ºC
Storage:-40ºC~125ºC
Vibration10-40Hz,DA1.27mm, 40-70Hz:5g
70-100Hz:DA0.5mm,100-500Hz:5g
Shock Resistance:20g, 11ms
Dielectric Strength500Vrms, 1 min

   
Cautions of New Energy Relay:
   
1.Ordering Information
    1.1 The biggest differences between this new energy relay and traditional latching relay or power relay are:
    the wider contact distance and stronger dielectric strength of 4000Vac instead of 1500 /2000Vac.
    So the contact distance can be 3mm or normal type.
   1.2 The nominal voltage of coil are 12Vdc and 24Vdc with the low power consumption of 1.8W or 3W.
   Plz note that you should drive the circuit/coil with step-down voltage to ensure power consumption of 1W~1.5W.
   1.3 Two poles of contacts of this relay, it means it can control 2 circuits and the default status is 2A- normally open.
   Simply put,
if you buy it as ev relay then most time the relay is open and not work, some times they are closed when charging.
   1.4 For environment-friendly, you can also choose this relay with lead or without lead (RoHs compliant)
   1.5 For more extra request on this relay plz feel free to contact us.

   2.Application:
   The typical application of this 40A new energy relay is AC slow charging pile.However if you would to adopt it into new area,
   plz don't hesitate to communicate with us at any time.The technical support and before-sales service are free for you.



           